Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing
BACKGROUND: Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is a material analysis technology which develops very fast in recent years. Resolution is an important factor used to estimate the performance of this technology. With greater resolution, it’s always easier to separate complex m...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729820/ https://www.ncbi.nlm.nih.gov/pubmed/23849221 http://dx.doi.org/10.1186/1752-153X-7-120 |
_version_ | 1782278996571979776 |
---|---|
author | Tang, Fei Xu, Chulong Wang, Xiaohao |
author_facet | Tang, Fei Xu, Chulong Wang, Xiaohao |
author_sort | Tang, Fei |
collection | PubMed |
description | BACKGROUND: Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is a material analysis technology which develops very fast in recent years. Resolution is an important factor used to estimate the performance of this technology. With greater resolution, it’s always easier to separate complex mixtures. RESULTS: A method to increase the resolution of FAIMS is put forward which focuses ions before they enter the drift tube. By adding several pairs of focus electrodes loaded with DC or RF voltage in front of the FAIMS drift tube, the height of the ion beam flowing into the drift tube is decreased, which improves the resolution of the FAIMS spectrum. The effectiveness of this method is verified through SIMION simulation and experiments. Both the DC focusing mode and the AC focusing mode can improve the resolution of the FAIMS system, with the biggest increase of 37%. CONCLUSIONS: Compared with other methods of improving FAIMS resolution, this method needs neither additional special gases, nor additional auxiliary equipment. It is easy to miniaturize, and can work under atmospheric pressure. |
format | Online Article Text |
id | pubmed-3729820 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-37298202013-08-01 Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing Tang, Fei Xu, Chulong Wang, Xiaohao Chem Cent J Research Article BACKGROUND: Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is a material analysis technology which develops very fast in recent years. Resolution is an important factor used to estimate the performance of this technology. With greater resolution, it’s always easier to separate complex mixtures. RESULTS: A method to increase the resolution of FAIMS is put forward which focuses ions before they enter the drift tube. By adding several pairs of focus electrodes loaded with DC or RF voltage in front of the FAIMS drift tube, the height of the ion beam flowing into the drift tube is decreased, which improves the resolution of the FAIMS spectrum. The effectiveness of this method is verified through SIMION simulation and experiments. Both the DC focusing mode and the AC focusing mode can improve the resolution of the FAIMS system, with the biggest increase of 37%. CONCLUSIONS: Compared with other methods of improving FAIMS resolution, this method needs neither additional special gases, nor additional auxiliary equipment. It is easy to miniaturize, and can work under atmospheric pressure. BioMed Central 2013-07-12 /pmc/articles/PMC3729820/ /pubmed/23849221 http://dx.doi.org/10.1186/1752-153X-7-120 Text en Copyright © 2013 Tang et al.; licensee Chemistry Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tang, Fei Xu, Chulong Wang, Xiaohao Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title | Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title_full | Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title_fullStr | Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title_full_unstemmed | Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title_short | Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing |
title_sort | resolution enhancement of field asymmetric waveform ion mobility spectrometry (faims) by ion focusing |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3729820/ https://www.ncbi.nlm.nih.gov/pubmed/23849221 http://dx.doi.org/10.1186/1752-153X-7-120 |
work_keys_str_mv | AT tangfei resolutionenhancementoffieldasymmetricwaveformionmobilityspectrometryfaimsbyionfocusing AT xuchulong resolutionenhancementoffieldasymmetricwaveformionmobilityspectrometryfaimsbyionfocusing AT wangxiaohao resolutionenhancementoffieldasymmetricwaveformionmobilityspectrometryfaimsbyionfocusing |