Cargando…

The accuracy of single emulsion radiographic film in linear measurement of spiral tomography

BACKGROUND: Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and cost in comparison to computed tomography (CT) and cone beam CT. Double emulsion film usually used for taking tomogr...

Descripción completa

Detalles Bibliográficos
Autores principales: Dabbaghi, Arash, Shokraneh, Ali, Farhadi, Nastaran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3731960/
https://www.ncbi.nlm.nih.gov/pubmed/23946736
_version_ 1782279221897330688
author Dabbaghi, Arash
Shokraneh, Ali
Farhadi, Nastaran
author_facet Dabbaghi, Arash
Shokraneh, Ali
Farhadi, Nastaran
author_sort Dabbaghi, Arash
collection PubMed
description BACKGROUND: Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and cost in comparison to computed tomography (CT) and cone beam CT. Double emulsion film usually used for taking tomograms requires less exposure than single emulsion film; on the other hand, the latter provides more sharpness and spatial resolution. The aim of this study was to compare diagnostic accuracy of these two kinds of films in the spiral tomography. MATERIALS AND METHODS: In an experimental study, 20 lines (10 lines anterior and 10 lines posterior to the mental foramen) were selected on two dry human mandibles and tomographic images were taken from each line with and without metal marker by single and double emulsion films. For quantitative assessment, the mandibular width and length was identified and measured on 80obtained tomograms. Afterwards, the mandibles were sectioned on each line and their actual width and height were measured. For each line, the data of tomograms were subtracted from gold standard as measurement error. These errors were divided into three groups: Greater than +1 mm, between +1 mm and −1 mm and less than −1 mm. Obtained data were analyzed by Pearson Chi-square test (α=0/05). RESULTS: There was no significant difference between the single and double emulsion films, with and without markers in the measurement of both height and width of mandible (P > 0.05). CONCLUSION: The single emulsion film is not recommended to be used for taking the spiral tomogram.
format Online
Article
Text
id pubmed-3731960
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37319602013-08-14 The accuracy of single emulsion radiographic film in linear measurement of spiral tomography Dabbaghi, Arash Shokraneh, Ali Farhadi, Nastaran Dent Res J (Isfahan) Original Article BACKGROUND: Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and cost in comparison to computed tomography (CT) and cone beam CT. Double emulsion film usually used for taking tomograms requires less exposure than single emulsion film; on the other hand, the latter provides more sharpness and spatial resolution. The aim of this study was to compare diagnostic accuracy of these two kinds of films in the spiral tomography. MATERIALS AND METHODS: In an experimental study, 20 lines (10 lines anterior and 10 lines posterior to the mental foramen) were selected on two dry human mandibles and tomographic images were taken from each line with and without metal marker by single and double emulsion films. For quantitative assessment, the mandibular width and length was identified and measured on 80obtained tomograms. Afterwards, the mandibles were sectioned on each line and their actual width and height were measured. For each line, the data of tomograms were subtracted from gold standard as measurement error. These errors were divided into three groups: Greater than +1 mm, between +1 mm and −1 mm and less than −1 mm. Obtained data were analyzed by Pearson Chi-square test (α=0/05). RESULTS: There was no significant difference between the single and double emulsion films, with and without markers in the measurement of both height and width of mandible (P > 0.05). CONCLUSION: The single emulsion film is not recommended to be used for taking the spiral tomogram. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3731960/ /pubmed/23946736 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dabbaghi, Arash
Shokraneh, Ali
Farhadi, Nastaran
The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title_full The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title_fullStr The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title_full_unstemmed The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title_short The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
title_sort accuracy of single emulsion radiographic film in linear measurement of spiral tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3731960/
https://www.ncbi.nlm.nih.gov/pubmed/23946736
work_keys_str_mv AT dabbaghiarash theaccuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography
AT shokranehali theaccuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography
AT farhadinastaran theaccuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography
AT dabbaghiarash accuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography
AT shokranehali accuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography
AT farhadinastaran accuracyofsingleemulsionradiographicfilminlinearmeasurementofspiraltomography