Cargando…
A framework for deformable image registration validation in radiotherapy clinical applications
Quantitative validation of deformable image registration (DIR) algorithms is extremely difficult because of the complexity involved in constructing a deformable phantom that can duplicate various clinical scenarios. The purpose of this study is to describe a framework to test the accuracy of DIR bas...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732001/ https://www.ncbi.nlm.nih.gov/pubmed/23318394 http://dx.doi.org/10.1120/jacmp.v14i1.4066 |
_version_ | 1782279225597755392 |
---|---|
author | Varadhan, Raj Karangelis, Grigorios Krishnan, Karthik Hui, Susanta |
author_facet | Varadhan, Raj Karangelis, Grigorios Krishnan, Karthik Hui, Susanta |
author_sort | Varadhan, Raj |
collection | PubMed |
description | Quantitative validation of deformable image registration (DIR) algorithms is extremely difficult because of the complexity involved in constructing a deformable phantom that can duplicate various clinical scenarios. The purpose of this study is to describe a framework to test the accuracy of DIR based on computational modeling and evaluating using inverse consistency and other methods. Three clinically relevant organ deformations were created in prostate (distended rectum and rectal gas), head and neck (large neck flexion), and lung (inhale and exhale lung volumes with variable contrast enhancement) study sets. DIR was performed using both B‐spline and diffeomorphic demons algorithms in the forward and inverse direction. A compositive accumulation of forward and inverse deformation vector fields was done to quantify the inverse consistency error (ICE). The anatomical correspondence of tumor and organs at risk was quantified by comparing the original RT structures with those obtained after DIR. Further, the physical characteristics of the deformation field, namely the Jacobian and harmonic energy, were computed to quantify the preservation of image topology and regularity of spatial transformation obtained in DIR. The ICE was comparable in prostate case but the B‐spline algorithm had significantly better anatomical correspondence for rectum and prostate than diffeomorphic demons algorithm. The ICE was 6.5 mm for demons algorithm for head and neck case when compared to 0.7 mm for B‐spline. Since the induced neck flexion was large, the average Dice similarity coefficient between both algorithms was only 0.87, 0.52, 0.81, and 0.67 for tumor, cord, parotids, and mandible, respectively. The B‐spline algorithm accurately estimated deformations between images with variable contrast in our lung study, while diffeomorphic demons algorithm led to gross errors on structures affected by contrast variation. The proposed framework offers the application of known deformations on any image datasets, to evaluate the overall accuracy and limitations of a DIR algorithm used in radiation oncology. The evaluation based on anatomical correspondence, physical characteristics of deformation field, and image characteristics can facilitate DIR verification with the ultimate goal of implementing adaptive radiotherapy. The suitability of application of a particular evaluation metric in validating DIR is dependent on the clinical deformation observed. PACS numbers: 87.57 nj, 87.55‐x,87.55 Qr |
format | Online Article Text |
id | pubmed-3732001 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-37320012018-04-02 A framework for deformable image registration validation in radiotherapy clinical applications Varadhan, Raj Karangelis, Grigorios Krishnan, Karthik Hui, Susanta J Appl Clin Med Phys Radiation Oncology Physics Quantitative validation of deformable image registration (DIR) algorithms is extremely difficult because of the complexity involved in constructing a deformable phantom that can duplicate various clinical scenarios. The purpose of this study is to describe a framework to test the accuracy of DIR based on computational modeling and evaluating using inverse consistency and other methods. Three clinically relevant organ deformations were created in prostate (distended rectum and rectal gas), head and neck (large neck flexion), and lung (inhale and exhale lung volumes with variable contrast enhancement) study sets. DIR was performed using both B‐spline and diffeomorphic demons algorithms in the forward and inverse direction. A compositive accumulation of forward and inverse deformation vector fields was done to quantify the inverse consistency error (ICE). The anatomical correspondence of tumor and organs at risk was quantified by comparing the original RT structures with those obtained after DIR. Further, the physical characteristics of the deformation field, namely the Jacobian and harmonic energy, were computed to quantify the preservation of image topology and regularity of spatial transformation obtained in DIR. The ICE was comparable in prostate case but the B‐spline algorithm had significantly better anatomical correspondence for rectum and prostate than diffeomorphic demons algorithm. The ICE was 6.5 mm for demons algorithm for head and neck case when compared to 0.7 mm for B‐spline. Since the induced neck flexion was large, the average Dice similarity coefficient between both algorithms was only 0.87, 0.52, 0.81, and 0.67 for tumor, cord, parotids, and mandible, respectively. The B‐spline algorithm accurately estimated deformations between images with variable contrast in our lung study, while diffeomorphic demons algorithm led to gross errors on structures affected by contrast variation. The proposed framework offers the application of known deformations on any image datasets, to evaluate the overall accuracy and limitations of a DIR algorithm used in radiation oncology. The evaluation based on anatomical correspondence, physical characteristics of deformation field, and image characteristics can facilitate DIR verification with the ultimate goal of implementing adaptive radiotherapy. The suitability of application of a particular evaluation metric in validating DIR is dependent on the clinical deformation observed. PACS numbers: 87.57 nj, 87.55‐x,87.55 Qr John Wiley and Sons Inc. 2013-01-02 /pmc/articles/PMC3732001/ /pubmed/23318394 http://dx.doi.org/10.1120/jacmp.v14i1.4066 Text en © 2013 The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Varadhan, Raj Karangelis, Grigorios Krishnan, Karthik Hui, Susanta A framework for deformable image registration validation in radiotherapy clinical applications |
title | A framework for deformable image registration validation in radiotherapy clinical applications |
title_full | A framework for deformable image registration validation in radiotherapy clinical applications |
title_fullStr | A framework for deformable image registration validation in radiotherapy clinical applications |
title_full_unstemmed | A framework for deformable image registration validation in radiotherapy clinical applications |
title_short | A framework for deformable image registration validation in radiotherapy clinical applications |
title_sort | framework for deformable image registration validation in radiotherapy clinical applications |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732001/ https://www.ncbi.nlm.nih.gov/pubmed/23318394 http://dx.doi.org/10.1120/jacmp.v14i1.4066 |
work_keys_str_mv | AT varadhanraj aframeworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT karangelisgrigorios aframeworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT krishnankarthik aframeworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT huisusanta aframeworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT varadhanraj frameworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT karangelisgrigorios frameworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT krishnankarthik frameworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications AT huisusanta frameworkfordeformableimageregistrationvalidationinradiotherapyclinicalapplications |