Cargando…

Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method

A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × ...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Zhikui, Ma, Suying, Wang, Jincai, Shang, Xiaojun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732613/
https://www.ncbi.nlm.nih.gov/pubmed/23971001
http://dx.doi.org/10.1155/2013/185706
_version_ 1782279283999244288
author Yin, Zhikui
Ma, Suying
Wang, Jincai
Shang, Xiaojun
author_facet Yin, Zhikui
Ma, Suying
Wang, Jincai
Shang, Xiaojun
author_sort Yin, Zhikui
collection PubMed
description A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0–100.0 μg/mL (r = 0.9954) and 20.0–200.0 μg/mL (r = 0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion.
format Online
Article
Text
id pubmed-3732613
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37326132013-08-22 Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method Yin, Zhikui Ma, Suying Wang, Jincai Shang, Xiaojun J Anal Methods Chem Research Article A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0–100.0 μg/mL (r = 0.9954) and 20.0–200.0 μg/mL (r = 0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion. Hindawi Publishing Corporation 2013 2013-07-18 /pmc/articles/PMC3732613/ /pubmed/23971001 http://dx.doi.org/10.1155/2013/185706 Text en Copyright © 2013 Zhikui Yin et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yin, Zhikui
Ma, Suying
Wang, Jincai
Shang, Xiaojun
Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title_full Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title_fullStr Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title_full_unstemmed Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title_short Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
title_sort simultaneous determination of matrine and tinidazole in compound lotion by rh-hplc method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732613/
https://www.ncbi.nlm.nih.gov/pubmed/23971001
http://dx.doi.org/10.1155/2013/185706
work_keys_str_mv AT yinzhikui simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod
AT masuying simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod
AT wangjincai simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod
AT shangxiaojun simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod