Cargando…
Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method
A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × ...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732613/ https://www.ncbi.nlm.nih.gov/pubmed/23971001 http://dx.doi.org/10.1155/2013/185706 |
_version_ | 1782279283999244288 |
---|---|
author | Yin, Zhikui Ma, Suying Wang, Jincai Shang, Xiaojun |
author_facet | Yin, Zhikui Ma, Suying Wang, Jincai Shang, Xiaojun |
author_sort | Yin, Zhikui |
collection | PubMed |
description | A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0–100.0 μg/mL (r = 0.9954) and 20.0–200.0 μg/mL (r = 0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion. |
format | Online Article Text |
id | pubmed-3732613 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-37326132013-08-22 Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method Yin, Zhikui Ma, Suying Wang, Jincai Shang, Xiaojun J Anal Methods Chem Research Article A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C(18) column (5 μm, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0–100.0 μg/mL (r = 0.9954) and 20.0–200.0 μg/mL (r = 0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion. Hindawi Publishing Corporation 2013 2013-07-18 /pmc/articles/PMC3732613/ /pubmed/23971001 http://dx.doi.org/10.1155/2013/185706 Text en Copyright © 2013 Zhikui Yin et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Yin, Zhikui Ma, Suying Wang, Jincai Shang, Xiaojun Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title | Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title_full | Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title_fullStr | Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title_full_unstemmed | Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title_short | Simultaneous Determination of Matrine and Tinidazole in Compound Lotion by RH-HPLC Method |
title_sort | simultaneous determination of matrine and tinidazole in compound lotion by rh-hplc method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732613/ https://www.ncbi.nlm.nih.gov/pubmed/23971001 http://dx.doi.org/10.1155/2013/185706 |
work_keys_str_mv | AT yinzhikui simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod AT masuying simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod AT wangjincai simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod AT shangxiaojun simultaneousdeterminationofmatrineandtinidazoleincompoundlotionbyrhhplcmethod |