Cargando…

Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography

AIM: The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. METHODOLOGY: Three-dimensional reformatting images were reconstructed by cone be...

Descripción completa

Detalles Bibliográficos
Autores principales: Lai, Ren-fa, Zou, Hui, Kong, Wei-dong, Lin, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3733590/
https://www.ncbi.nlm.nih.gov/pubmed/20737936
http://dx.doi.org/10.4248/IJOS10036
_version_ 1782279365730500608
author Lai, Ren-fa
Zou, Hui
Kong, Wei-dong
Lin, Wei
author_facet Lai, Ren-fa
Zou, Hui
Kong, Wei-dong
Lin, Wei
author_sort Lai, Ren-fa
collection PubMed
description AIM: The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. METHODOLOGY: Three-dimensional reformatting images were reconstructed by cone beam computed tomography (CBCT) in 34 patients, aged 18 to 35 years, using EZ Implant software. Bone height was measured at 20 sites of interest on the palate. Bone mineral density was measured at the 10 sites with the highest implantation rate, classified using K-mean cluster analysis based on bone height and bone mineral density. RESULTS: According to the cluster analysis, 10 sites were classified into three clusters. Significant differences in bone height and bone mineral density were detected between these three clusters (P<0.05). The greatest bone height was obtained in cluster 2, followed by cluster 1 and cluster 3. The highest bone mineral density was found in cluster 3, followed by cluster 1 and cluster 2. CONCLUSION: CBCT plays an important role in pre-surgical treatment planning. CBCT is helpful in identifying safe and stable implantation sites for palatal anchorage.
format Online
Article
Text
id pubmed-3733590
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-37335902013-08-06 Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography Lai, Ren-fa Zou, Hui Kong, Wei-dong Lin, Wei Int J Oral Sci Original Scientific Article AIM: The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. METHODOLOGY: Three-dimensional reformatting images were reconstructed by cone beam computed tomography (CBCT) in 34 patients, aged 18 to 35 years, using EZ Implant software. Bone height was measured at 20 sites of interest on the palate. Bone mineral density was measured at the 10 sites with the highest implantation rate, classified using K-mean cluster analysis based on bone height and bone mineral density. RESULTS: According to the cluster analysis, 10 sites were classified into three clusters. Significant differences in bone height and bone mineral density were detected between these three clusters (P<0.05). The greatest bone height was obtained in cluster 2, followed by cluster 1 and cluster 3. The highest bone mineral density was found in cluster 3, followed by cluster 1 and cluster 2. CONCLUSION: CBCT plays an important role in pre-surgical treatment planning. CBCT is helpful in identifying safe and stable implantation sites for palatal anchorage. Nature Publishing Group 2010-06 /pmc/articles/PMC3733590/ /pubmed/20737936 http://dx.doi.org/10.4248/IJOS10036 Text en Copyright © 2010 West China School of Stomatology http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under the Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Original Scientific Article
Lai, Ren-fa
Zou, Hui
Kong, Wei-dong
Lin, Wei
Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title_full Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title_fullStr Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title_full_unstemmed Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title_short Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography
title_sort applied anatomic site study of palatal anchorage implants using cone beam computed tomography
topic Original Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3733590/
https://www.ncbi.nlm.nih.gov/pubmed/20737936
http://dx.doi.org/10.4248/IJOS10036
work_keys_str_mv AT lairenfa appliedanatomicsitestudyofpalatalanchorageimplantsusingconebeamcomputedtomography
AT zouhui appliedanatomicsitestudyofpalatalanchorageimplantsusingconebeamcomputedtomography
AT kongweidong appliedanatomicsitestudyofpalatalanchorageimplantsusingconebeamcomputedtomography
AT linwei appliedanatomicsitestudyofpalatalanchorageimplantsusingconebeamcomputedtomography