Cargando…
Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine
BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3733815/ https://www.ncbi.nlm.nih.gov/pubmed/23870697 http://dx.doi.org/10.1186/1532-429X-15-61 |
_version_ | 1782279411821707264 |
---|---|
author | Halabi, Majdi Faranesh, Anthony Z Schenke, William H Wright, Victor J Hansen, Michael S Saikus, Christina E Kocaturk, Ozgur Lederman, Robert J Ratnayaka, Kanishka |
author_facet | Halabi, Majdi Faranesh, Anthony Z Schenke, William H Wright, Victor J Hansen, Michael S Saikus, Christina E Kocaturk, Ozgur Lederman, Robert J Ratnayaka, Kanishka |
author_sort | Halabi, Majdi |
collection | PubMed |
description | BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals. Pericardiocentesis was performed in 2:47 ± 1:43 minutes; pericardial access was performed in 1:40 ± 4:34 minutes. The procedure was successful in all animals. Moderate and large effusions required only one needle pass. There were no complications, including pleural, hepatic or myocardial transit. CONCLUSIONS: CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in “difficult” pericardial access, for example, in distorted thoracic anatomy or loculated effusion. |
format | Online Article Text |
id | pubmed-3733815 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-37338152013-08-06 Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine Halabi, Majdi Faranesh, Anthony Z Schenke, William H Wright, Victor J Hansen, Michael S Saikus, Christina E Kocaturk, Ozgur Lederman, Robert J Ratnayaka, Kanishka J Cardiovasc Magn Reson Research BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals. Pericardiocentesis was performed in 2:47 ± 1:43 minutes; pericardial access was performed in 1:40 ± 4:34 minutes. The procedure was successful in all animals. Moderate and large effusions required only one needle pass. There were no complications, including pleural, hepatic or myocardial transit. CONCLUSIONS: CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in “difficult” pericardial access, for example, in distorted thoracic anatomy or loculated effusion. BioMed Central 2013-07-20 /pmc/articles/PMC3733815/ /pubmed/23870697 http://dx.doi.org/10.1186/1532-429X-15-61 Text en Copyright © 2013 Halabi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Halabi, Majdi Faranesh, Anthony Z Schenke, William H Wright, Victor J Hansen, Michael S Saikus, Christina E Kocaturk, Ozgur Lederman, Robert J Ratnayaka, Kanishka Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title | Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title_full | Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title_fullStr | Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title_full_unstemmed | Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title_short | Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
title_sort | real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3733815/ https://www.ncbi.nlm.nih.gov/pubmed/23870697 http://dx.doi.org/10.1186/1532-429X-15-61 |
work_keys_str_mv | AT halabimajdi realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT faraneshanthonyz realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT schenkewilliamh realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT wrightvictorj realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT hansenmichaels realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT saikuschristinae realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT kocaturkozgur realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT ledermanrobertj realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine AT ratnayakakanishka realtimecardiovascularmagneticresonancesubxiphoidpericardialaccessandpericardiocentesisusingofftheshelfdevicesinswine |