Cargando…

Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor

Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra...

Descripción completa

Detalles Bibliográficos
Autores principales: Ang, Lee Fung, Por, Lip Yee, Yam, Mun Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734260/
https://www.ncbi.nlm.nih.gov/pubmed/23940599
http://dx.doi.org/10.1371/journal.pone.0070597
_version_ 1782279509044625408
author Ang, Lee Fung
Por, Lip Yee
Yam, Mun Fei
author_facet Ang, Lee Fung
Por, Lip Yee
Yam, Mun Fei
author_sort Ang, Lee Fung
collection PubMed
description Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra showed the existence of intermolecular interactions between chitosan and glucose oxidase (GOD). Higher catalytic activities were observed on for GOD-MMCHI than GOD-LMCHI and for those crosslinked with glutaraldehyde than using the adsorption technique. Enzyme loading greater than 0.6 mg decreased the activity. Under optimum conditions (pH 6.0, 35°C and applied potential of 0.6 V) response times of 85 s and 65 s were observed for medium molecular weight chitosan glucose biosensor (GOD-MMCHI/PT) and low molecular weight chitosan glucose biosensor (GOD-LMCHI/PT), respectively. The apparent Michaelis-Menten constant ([Image: see text]) was found to be 12.737 mM for GOD-MMCHI/PT and 17.692 mM for GOD-LMCHI/PT. This indicated that GOD-MMCHI/PT had greater affinity for the enzyme. Moreover, GOD-MMCHI/PT showed higher sensitivity (52.3666 nA/mM glucose) when compared with GOD-LMCHI/PT (9.8579 nA/mM glucose) at S/N>3. Better repeatability and reproducibility were achieved with GOD-MMCHI/PT than GOD-LMCHI/PT regarding glucose measurement. GOD-MMCHI/PT was found to give the highest enzymatic activity among the electrodes under investigation. The extent of interference encountered by GOD-MMCHI/PT and GOD-LMCHI/PT was not significantly different. Although the Nafion coated biosensor significantly reduced the signal due to the interferents under study, it also significantly reduced the response to glucose. The performance of the biosensors in the determination of glucose in rat serum was evaluated. Comparatively better accuracy and recovery results were obtained for GOD-MMCHI/PT. Hence, GOD-MMCHI/PT showed a better performance when compared with GOD-LMCHI/PT. In conclusion, chitosan membranes shave the potential to be a suitable matrix for the development of glucose biosensors.
format Online
Article
Text
id pubmed-3734260
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37342602013-08-12 Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor Ang, Lee Fung Por, Lip Yee Yam, Mun Fei PLoS One Research Article Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra showed the existence of intermolecular interactions between chitosan and glucose oxidase (GOD). Higher catalytic activities were observed on for GOD-MMCHI than GOD-LMCHI and for those crosslinked with glutaraldehyde than using the adsorption technique. Enzyme loading greater than 0.6 mg decreased the activity. Under optimum conditions (pH 6.0, 35°C and applied potential of 0.6 V) response times of 85 s and 65 s were observed for medium molecular weight chitosan glucose biosensor (GOD-MMCHI/PT) and low molecular weight chitosan glucose biosensor (GOD-LMCHI/PT), respectively. The apparent Michaelis-Menten constant ([Image: see text]) was found to be 12.737 mM for GOD-MMCHI/PT and 17.692 mM for GOD-LMCHI/PT. This indicated that GOD-MMCHI/PT had greater affinity for the enzyme. Moreover, GOD-MMCHI/PT showed higher sensitivity (52.3666 nA/mM glucose) when compared with GOD-LMCHI/PT (9.8579 nA/mM glucose) at S/N>3. Better repeatability and reproducibility were achieved with GOD-MMCHI/PT than GOD-LMCHI/PT regarding glucose measurement. GOD-MMCHI/PT was found to give the highest enzymatic activity among the electrodes under investigation. The extent of interference encountered by GOD-MMCHI/PT and GOD-LMCHI/PT was not significantly different. Although the Nafion coated biosensor significantly reduced the signal due to the interferents under study, it also significantly reduced the response to glucose. The performance of the biosensors in the determination of glucose in rat serum was evaluated. Comparatively better accuracy and recovery results were obtained for GOD-MMCHI/PT. Hence, GOD-MMCHI/PT showed a better performance when compared with GOD-LMCHI/PT. In conclusion, chitosan membranes shave the potential to be a suitable matrix for the development of glucose biosensors. Public Library of Science 2013-08-05 /pmc/articles/PMC3734260/ /pubmed/23940599 http://dx.doi.org/10.1371/journal.pone.0070597 Text en © 2013 Ang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Ang, Lee Fung
Por, Lip Yee
Yam, Mun Fei
Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title_full Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title_fullStr Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title_full_unstemmed Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title_short Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
title_sort study on different molecular weights of chitosan as an immobilization matrix for a glucose biosensor
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734260/
https://www.ncbi.nlm.nih.gov/pubmed/23940599
http://dx.doi.org/10.1371/journal.pone.0070597
work_keys_str_mv AT angleefung studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor
AT porlipyee studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor
AT yammunfei studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor