Cargando…
Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor
Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734260/ https://www.ncbi.nlm.nih.gov/pubmed/23940599 http://dx.doi.org/10.1371/journal.pone.0070597 |
_version_ | 1782279509044625408 |
---|---|
author | Ang, Lee Fung Por, Lip Yee Yam, Mun Fei |
author_facet | Ang, Lee Fung Por, Lip Yee Yam, Mun Fei |
author_sort | Ang, Lee Fung |
collection | PubMed |
description | Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra showed the existence of intermolecular interactions between chitosan and glucose oxidase (GOD). Higher catalytic activities were observed on for GOD-MMCHI than GOD-LMCHI and for those crosslinked with glutaraldehyde than using the adsorption technique. Enzyme loading greater than 0.6 mg decreased the activity. Under optimum conditions (pH 6.0, 35°C and applied potential of 0.6 V) response times of 85 s and 65 s were observed for medium molecular weight chitosan glucose biosensor (GOD-MMCHI/PT) and low molecular weight chitosan glucose biosensor (GOD-LMCHI/PT), respectively. The apparent Michaelis-Menten constant ([Image: see text]) was found to be 12.737 mM for GOD-MMCHI/PT and 17.692 mM for GOD-LMCHI/PT. This indicated that GOD-MMCHI/PT had greater affinity for the enzyme. Moreover, GOD-MMCHI/PT showed higher sensitivity (52.3666 nA/mM glucose) when compared with GOD-LMCHI/PT (9.8579 nA/mM glucose) at S/N>3. Better repeatability and reproducibility were achieved with GOD-MMCHI/PT than GOD-LMCHI/PT regarding glucose measurement. GOD-MMCHI/PT was found to give the highest enzymatic activity among the electrodes under investigation. The extent of interference encountered by GOD-MMCHI/PT and GOD-LMCHI/PT was not significantly different. Although the Nafion coated biosensor significantly reduced the signal due to the interferents under study, it also significantly reduced the response to glucose. The performance of the biosensors in the determination of glucose in rat serum was evaluated. Comparatively better accuracy and recovery results were obtained for GOD-MMCHI/PT. Hence, GOD-MMCHI/PT showed a better performance when compared with GOD-LMCHI/PT. In conclusion, chitosan membranes shave the potential to be a suitable matrix for the development of glucose biosensors. |
format | Online Article Text |
id | pubmed-3734260 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-37342602013-08-12 Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor Ang, Lee Fung Por, Lip Yee Yam, Mun Fei PLoS One Research Article Two chitosan samples (medium molecular weight (MMCHI) and low molecular weight (LMCHI)) were investigated as an enzyme immobilization matrix for the fabrication of a glucose biosensor. Chitosan membranes prepared from acetic acid were flexible, transparent, smooth and quick-drying. The FTIR spectra showed the existence of intermolecular interactions between chitosan and glucose oxidase (GOD). Higher catalytic activities were observed on for GOD-MMCHI than GOD-LMCHI and for those crosslinked with glutaraldehyde than using the adsorption technique. Enzyme loading greater than 0.6 mg decreased the activity. Under optimum conditions (pH 6.0, 35°C and applied potential of 0.6 V) response times of 85 s and 65 s were observed for medium molecular weight chitosan glucose biosensor (GOD-MMCHI/PT) and low molecular weight chitosan glucose biosensor (GOD-LMCHI/PT), respectively. The apparent Michaelis-Menten constant ([Image: see text]) was found to be 12.737 mM for GOD-MMCHI/PT and 17.692 mM for GOD-LMCHI/PT. This indicated that GOD-MMCHI/PT had greater affinity for the enzyme. Moreover, GOD-MMCHI/PT showed higher sensitivity (52.3666 nA/mM glucose) when compared with GOD-LMCHI/PT (9.8579 nA/mM glucose) at S/N>3. Better repeatability and reproducibility were achieved with GOD-MMCHI/PT than GOD-LMCHI/PT regarding glucose measurement. GOD-MMCHI/PT was found to give the highest enzymatic activity among the electrodes under investigation. The extent of interference encountered by GOD-MMCHI/PT and GOD-LMCHI/PT was not significantly different. Although the Nafion coated biosensor significantly reduced the signal due to the interferents under study, it also significantly reduced the response to glucose. The performance of the biosensors in the determination of glucose in rat serum was evaluated. Comparatively better accuracy and recovery results were obtained for GOD-MMCHI/PT. Hence, GOD-MMCHI/PT showed a better performance when compared with GOD-LMCHI/PT. In conclusion, chitosan membranes shave the potential to be a suitable matrix for the development of glucose biosensors. Public Library of Science 2013-08-05 /pmc/articles/PMC3734260/ /pubmed/23940599 http://dx.doi.org/10.1371/journal.pone.0070597 Text en © 2013 Ang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Ang, Lee Fung Por, Lip Yee Yam, Mun Fei Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title | Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title_full | Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title_fullStr | Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title_full_unstemmed | Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title_short | Study on Different Molecular Weights of Chitosan as an Immobilization Matrix for a Glucose Biosensor |
title_sort | study on different molecular weights of chitosan as an immobilization matrix for a glucose biosensor |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3734260/ https://www.ncbi.nlm.nih.gov/pubmed/23940599 http://dx.doi.org/10.1371/journal.pone.0070597 |
work_keys_str_mv | AT angleefung studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor AT porlipyee studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor AT yammunfei studyondifferentmolecularweightsofchitosanasanimmobilizationmatrixforaglucosebiosensor |