Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus
We report the case of a 64-year-old patient in whom a pulmonary artery catheter formed a knot fixed within the right ventricle in the region of the tricuspid valve apparatus. Knot formation is a recognized complication associated with pulmonary artery catheters (PAC) insertion. This problem is usual...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737698/ https://www.ncbi.nlm.nih.gov/pubmed/23956722 http://dx.doi.org/10.4103/1658-354X.114048 |
_version_ | 1782279896560566272 |
---|---|
author | Ishaq, Muhammad Alexander, Nicki Scott, David H. T. |
author_facet | Ishaq, Muhammad Alexander, Nicki Scott, David H. T. |
author_sort | Ishaq, Muhammad |
collection | PubMed |
description | We report the case of a 64-year-old patient in whom a pulmonary artery catheter formed a knot fixed within the right ventricle in the region of the tricuspid valve apparatus. Knot formation is a recognized complication associated with pulmonary artery catheters (PAC) insertion. This problem is usually dealt with by simply withdrawing the PAC until the knot impacts onto the introducer and after enlarging the puncture site by a small skin incision removing the introducer-PAC as one unit. However, we recently encountered a situation where the PAC was knotted around the tricuspid valve apparatus and could not be withdrawn. An interventional radiologist was able to unknot the catheter and release it from the tricuspid valve. We reviewed the literature related to this topic. We believe our experience could be of use to others. |
format | Online Article Text |
id | pubmed-3737698 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-37376982013-08-16 Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus Ishaq, Muhammad Alexander, Nicki Scott, David H. T. Saudi J Anaesth Case Report We report the case of a 64-year-old patient in whom a pulmonary artery catheter formed a knot fixed within the right ventricle in the region of the tricuspid valve apparatus. Knot formation is a recognized complication associated with pulmonary artery catheters (PAC) insertion. This problem is usually dealt with by simply withdrawing the PAC until the knot impacts onto the introducer and after enlarging the puncture site by a small skin incision removing the introducer-PAC as one unit. However, we recently encountered a situation where the PAC was knotted around the tricuspid valve apparatus and could not be withdrawn. An interventional radiologist was able to unknot the catheter and release it from the tricuspid valve. We reviewed the literature related to this topic. We believe our experience could be of use to others. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3737698/ /pubmed/23956722 http://dx.doi.org/10.4103/1658-354X.114048 Text en Copyright: © Saudi Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Ishaq, Muhammad Alexander, Nicki Scott, David H. T. Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title | Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title_full | Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title_fullStr | Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title_full_unstemmed | Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title_short | Successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
title_sort | successful retrieval of a knotted pulmonary artery catheter trapped in the tricuspid valve apparatus |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737698/ https://www.ncbi.nlm.nih.gov/pubmed/23956722 http://dx.doi.org/10.4103/1658-354X.114048 |
work_keys_str_mv | AT ishaqmuhammad successfulretrievalofaknottedpulmonaryarterycathetertrappedinthetricuspidvalveapparatus AT alexandernicki successfulretrievalofaknottedpulmonaryarterycathetertrappedinthetricuspidvalveapparatus AT scottdavidht successfulretrievalofaknottedpulmonaryarterycathetertrappedinthetricuspidvalveapparatus |