Cargando…

Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter

An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a...

Descripción completa

Detalles Bibliográficos
Autores principales: Hwang, Sung Mi, Lee, Jae Jun, Jang, Ji Su, Lee, Nak Hum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737699/
https://www.ncbi.nlm.nih.gov/pubmed/23956723
http://dx.doi.org/10.4103/1658-354X.114050
_version_ 1782279896783912960
author Hwang, Sung Mi
Lee, Jae Jun
Jang, Ji Su
Lee, Nak Hum
author_facet Hwang, Sung Mi
Lee, Jae Jun
Jang, Ji Su
Lee, Nak Hum
author_sort Hwang, Sung Mi
collection PubMed
description An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a guidewire. To avoid this, physicians should consider the insertion depth and maintenance depth of the AEC and should verify its position before changing ETTs and should perform, if possible, with simultaneous visualization of the glottis with direct or video laryngoscopy during the exchange. Additionally, the new ETT position should be confirmed by auscultation, end-tidal carbon dioxide, and portable chest X-ray.
format Online
Article
Text
id pubmed-3737699
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37376992013-08-16 Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter Hwang, Sung Mi Lee, Jae Jun Jang, Ji Su Lee, Nak Hum Saudi J Anaesth Case Report An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a guidewire. To avoid this, physicians should consider the insertion depth and maintenance depth of the AEC and should verify its position before changing ETTs and should perform, if possible, with simultaneous visualization of the glottis with direct or video laryngoscopy during the exchange. Additionally, the new ETT position should be confirmed by auscultation, end-tidal carbon dioxide, and portable chest X-ray. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3737699/ /pubmed/23956723 http://dx.doi.org/10.4103/1658-354X.114050 Text en Copyright: © Saudi Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Hwang, Sung Mi
Lee, Jae Jun
Jang, Ji Su
Lee, Nak Hum
Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title_full Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title_fullStr Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title_full_unstemmed Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title_short Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
title_sort esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737699/
https://www.ncbi.nlm.nih.gov/pubmed/23956723
http://dx.doi.org/10.4103/1658-354X.114050
work_keys_str_mv AT hwangsungmi esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter
AT leejaejun esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter
AT jangjisu esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter
AT leenakhum esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter