Cargando…
Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter
An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737699/ https://www.ncbi.nlm.nih.gov/pubmed/23956723 http://dx.doi.org/10.4103/1658-354X.114050 |
_version_ | 1782279896783912960 |
---|---|
author | Hwang, Sung Mi Lee, Jae Jun Jang, Ji Su Lee, Nak Hum |
author_facet | Hwang, Sung Mi Lee, Jae Jun Jang, Ji Su Lee, Nak Hum |
author_sort | Hwang, Sung Mi |
collection | PubMed |
description | An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a guidewire. To avoid this, physicians should consider the insertion depth and maintenance depth of the AEC and should verify its position before changing ETTs and should perform, if possible, with simultaneous visualization of the glottis with direct or video laryngoscopy during the exchange. Additionally, the new ETT position should be confirmed by auscultation, end-tidal carbon dioxide, and portable chest X-ray. |
format | Online Article Text |
id | pubmed-3737699 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-37376992013-08-16 Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter Hwang, Sung Mi Lee, Jae Jun Jang, Ji Su Lee, Nak Hum Saudi J Anaesth Case Report An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a guidewire. To avoid this, physicians should consider the insertion depth and maintenance depth of the AEC and should verify its position before changing ETTs and should perform, if possible, with simultaneous visualization of the glottis with direct or video laryngoscopy during the exchange. Additionally, the new ETT position should be confirmed by auscultation, end-tidal carbon dioxide, and portable chest X-ray. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3737699/ /pubmed/23956723 http://dx.doi.org/10.4103/1658-354X.114050 Text en Copyright: © Saudi Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Hwang, Sung Mi Lee, Jae Jun Jang, Ji Su Lee, Nak Hum Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title | Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title_full | Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title_fullStr | Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title_full_unstemmed | Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title_short | Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
title_sort | esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737699/ https://www.ncbi.nlm.nih.gov/pubmed/23956723 http://dx.doi.org/10.4103/1658-354X.114050 |
work_keys_str_mv | AT hwangsungmi esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter AT leejaejun esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter AT jangjisu esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter AT leenakhum esophagealmisplacementofasinglelumentubeafteritsexchangeforadoublelumentubedespitetheuseofanairwayexchangecatheter |