Cargando…

Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations

PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial leng...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Joo Youn, Lee, Jae Bum, Seo, Kyoung Yul, Kim, Eung Kweon, Kim, Tae-im
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3743187/
https://www.ncbi.nlm.nih.gov/pubmed/23918579
http://dx.doi.org/10.3349/ymj.2013.54.5.1259
_version_ 1782280459436163072
author Shin, Joo Youn
Lee, Jae Bum
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
author_facet Shin, Joo Youn
Lee, Jae Bum
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
author_sort Shin, Joo Youn
collection PubMed
description PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.
format Online
Article
Text
id pubmed-3743187
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-37431872013-09-01 Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations Shin, Joo Youn Lee, Jae Bum Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im Yonsei Med J Original Article PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation. Yonsei University College of Medicine 2013-09-01 2013-07-23 /pmc/articles/PMC3743187/ /pubmed/23918579 http://dx.doi.org/10.3349/ymj.2013.54.5.1259 Text en © Copyright: Yonsei University College of Medicine 2013 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Shin, Joo Youn
Lee, Jae Bum
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title_full Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title_fullStr Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title_full_unstemmed Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title_short Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
title_sort comparison of preoperative and postoperative ocular biometry in eyes with phakic intraocular lens implantations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3743187/
https://www.ncbi.nlm.nih.gov/pubmed/23918579
http://dx.doi.org/10.3349/ymj.2013.54.5.1259
work_keys_str_mv AT shinjooyoun comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations
AT leejaebum comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations
AT seokyoungyul comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations
AT kimeungkweon comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations
AT kimtaeim comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations