Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations
PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial leng...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3743187/ https://www.ncbi.nlm.nih.gov/pubmed/23918579 http://dx.doi.org/10.3349/ymj.2013.54.5.1259 |
_version_ | 1782280459436163072 |
---|---|
author | Shin, Joo Youn Lee, Jae Bum Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im |
author_facet | Shin, Joo Youn Lee, Jae Bum Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im |
author_sort | Shin, Joo Youn |
collection | PubMed |
description | PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation. |
format | Online Article Text |
id | pubmed-3743187 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-37431872013-09-01 Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations Shin, Joo Youn Lee, Jae Bum Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im Yonsei Med J Original Article PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation. Yonsei University College of Medicine 2013-09-01 2013-07-23 /pmc/articles/PMC3743187/ /pubmed/23918579 http://dx.doi.org/10.3349/ymj.2013.54.5.1259 Text en © Copyright: Yonsei University College of Medicine 2013 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shin, Joo Youn Lee, Jae Bum Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title | Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title_full | Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title_fullStr | Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title_full_unstemmed | Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title_short | Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations |
title_sort | comparison of preoperative and postoperative ocular biometry in eyes with phakic intraocular lens implantations |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3743187/ https://www.ncbi.nlm.nih.gov/pubmed/23918579 http://dx.doi.org/10.3349/ymj.2013.54.5.1259 |
work_keys_str_mv | AT shinjooyoun comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations AT leejaebum comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations AT seokyoungyul comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations AT kimeungkweon comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations AT kimtaeim comparisonofpreoperativeandpostoperativeocularbiometryineyeswithphakicintraocularlensimplantations |