Cargando…
Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing
A ptychographic coherent X-ray diffractive imaging (PCDI) experiment has been carried out using 7.9 keV X-rays and Kirkpatrick–Baez focusing mirrors. By introducing a semi-transparent central stop in front of the detector the dynamic range on the detector is increased by about four orders of magnitu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3744854/ http://dx.doi.org/10.1107/S0108767313019612 |
_version_ | 1782280655240953856 |
---|---|
author | Wilke, R. N. Vassholz, M. Salditt, T. |
author_facet | Wilke, R. N. Vassholz, M. Salditt, T. |
author_sort | Wilke, R. N. |
collection | PubMed |
description | A ptychographic coherent X-ray diffractive imaging (PCDI) experiment has been carried out using 7.9 keV X-rays and Kirkpatrick–Baez focusing mirrors. By introducing a semi-transparent central stop in front of the detector the dynamic range on the detector is increased by about four orders of magnitude. The feasibility of this experimental scheme is demonstrated for PCDI applications with a resolution below 10 nm. The results are compared with reference data and an increase of resolution by a factor of two is obtained, while the deviation of the reconstructed phase map from the reference is below 1%. |
format | Online Article Text |
id | pubmed-3744854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-37448542013-08-21 Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing Wilke, R. N. Vassholz, M. Salditt, T. Acta Crystallogr A Research Papers A ptychographic coherent X-ray diffractive imaging (PCDI) experiment has been carried out using 7.9 keV X-rays and Kirkpatrick–Baez focusing mirrors. By introducing a semi-transparent central stop in front of the detector the dynamic range on the detector is increased by about four orders of magnitude. The feasibility of this experimental scheme is demonstrated for PCDI applications with a resolution below 10 nm. The results are compared with reference data and an increase of resolution by a factor of two is obtained, while the deviation of the reconstructed phase map from the reference is below 1%. International Union of Crystallography 2013-09-01 2013-08-14 /pmc/articles/PMC3744854/ http://dx.doi.org/10.1107/S0108767313019612 Text en © R. N. Wilke et al. 2013 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Wilke, R. N. Vassholz, M. Salditt, T. Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title | Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title_full | Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title_fullStr | Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title_full_unstemmed | Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title_short | Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing |
title_sort | semi-transparent central stop in high-resolution x-ray ptychography using kirkpatrick–baez focusing |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3744854/ http://dx.doi.org/10.1107/S0108767313019612 |
work_keys_str_mv | AT wilkern semitransparentcentralstopinhighresolutionxrayptychographyusingkirkpatrickbaezfocusing AT vassholzm semitransparentcentralstopinhighresolutionxrayptychographyusingkirkpatrickbaezfocusing AT saldittt semitransparentcentralstopinhighresolutionxrayptychographyusingkirkpatrickbaezfocusing |