Cargando…

Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

BACKGROUND: The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS: Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and...

Descripción completa

Detalles Bibliográficos
Autores principales: Figueiredo, Bruno P, Cronemberger, Sebastião, Kanadani, Fabio N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745293/
https://www.ncbi.nlm.nih.gov/pubmed/23966769
http://dx.doi.org/10.2147/OPTH.S44523
_version_ 1782280679529119744
author Figueiredo, Bruno P
Cronemberger, Sebastião
Kanadani, Fabio N
author_facet Figueiredo, Bruno P
Cronemberger, Sebastião
Kanadani, Fabio N
author_sort Figueiredo, Bruno P
collection PubMed
description BACKGROUND: The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS: Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure (IOP) without evidence of glaucoma, and 30 had normal IOP (<21 mmHg) with no detectable glaucomatous damage. Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), blood pressure measurement, pachymetry, Humphrey visual field, and routine ophthalmic examination was performed in each patient. Ocular perfusion pressure was calculated as the difference between mean arterial pressure and IOP. The ocular pulse amplitude was given by DCT. The Pearson correlation coefficient was used to compare the glaucomatous and ocular hypertensive groups, and comparisons with the normal IOP group were done using the Spearman’s rank correlation coefficient. RESULTS: Mean IOP by DCT was 22.7 ± 4.3 mmHg in the glaucoma group, 22.3 ± 2.8 mmHg in the ocular hypertension group, and 14.3 ± 1.6 mmHg in the control group. Mean IOP by GAT was 19.0 ± 5.1 mmHg for glaucoma, 22.4 ± 2.1 mmHg for ocular hypertension, and 12.9 ± 2.2 mmHg for controls. Mean ocular pulse amplitude was 3.4 ± 1.2 mmHg in the glaucoma group, 3.5 ± 1.2 mmHg in the ocular hypertension group, and 2.6 ± 0.9 mmHg in the control group. Mean ocular perfusion pressure was 46.3 ± 7.9 mmHg in the glaucoma group, 46.3 ± 7.9 mmHg in the ocular hypertension group, and 50.2 ± 7.0 mmHg in controls. No significant correlation between ocular perfusion pressure and ocular pulse amplitude was found in any of the groups (P = 0.865 and r = −0.032, P = 0.403 and r = −0.156, P = 0.082 and ρ = −0.307 for glaucoma, ocular hypertension, and normal eyes, respectively). CONCLUSION: There is no significant correlation between ocular perfusion pressure and ocular pulse amplitude values in glaucoma, ocular hypertension, or normal eyes. IOP values measured by GAT correlate with those measured by DCT.
format Online
Article
Text
id pubmed-3745293
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-37452932013-08-21 Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes Figueiredo, Bruno P Cronemberger, Sebastião Kanadani, Fabio N Clin Ophthalmol Original Research BACKGROUND: The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS: Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure (IOP) without evidence of glaucoma, and 30 had normal IOP (<21 mmHg) with no detectable glaucomatous damage. Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), blood pressure measurement, pachymetry, Humphrey visual field, and routine ophthalmic examination was performed in each patient. Ocular perfusion pressure was calculated as the difference between mean arterial pressure and IOP. The ocular pulse amplitude was given by DCT. The Pearson correlation coefficient was used to compare the glaucomatous and ocular hypertensive groups, and comparisons with the normal IOP group were done using the Spearman’s rank correlation coefficient. RESULTS: Mean IOP by DCT was 22.7 ± 4.3 mmHg in the glaucoma group, 22.3 ± 2.8 mmHg in the ocular hypertension group, and 14.3 ± 1.6 mmHg in the control group. Mean IOP by GAT was 19.0 ± 5.1 mmHg for glaucoma, 22.4 ± 2.1 mmHg for ocular hypertension, and 12.9 ± 2.2 mmHg for controls. Mean ocular pulse amplitude was 3.4 ± 1.2 mmHg in the glaucoma group, 3.5 ± 1.2 mmHg in the ocular hypertension group, and 2.6 ± 0.9 mmHg in the control group. Mean ocular perfusion pressure was 46.3 ± 7.9 mmHg in the glaucoma group, 46.3 ± 7.9 mmHg in the ocular hypertension group, and 50.2 ± 7.0 mmHg in controls. No significant correlation between ocular perfusion pressure and ocular pulse amplitude was found in any of the groups (P = 0.865 and r = −0.032, P = 0.403 and r = −0.156, P = 0.082 and ρ = −0.307 for glaucoma, ocular hypertension, and normal eyes, respectively). CONCLUSION: There is no significant correlation between ocular perfusion pressure and ocular pulse amplitude values in glaucoma, ocular hypertension, or normal eyes. IOP values measured by GAT correlate with those measured by DCT. Dove Medical Press 2013 2013-08-09 /pmc/articles/PMC3745293/ /pubmed/23966769 http://dx.doi.org/10.2147/OPTH.S44523 Text en © 2013 Figueiredo et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Figueiredo, Bruno P
Cronemberger, Sebastião
Kanadani, Fabio N
Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title_full Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title_fullStr Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title_full_unstemmed Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title_short Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
title_sort correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745293/
https://www.ncbi.nlm.nih.gov/pubmed/23966769
http://dx.doi.org/10.2147/OPTH.S44523
work_keys_str_mv AT figueiredobrunop correlationbetweenocularperfusionpressureandocularpulseamplitudeinglaucomaocularhypertensionandnormaleyes
AT cronembergersebastiao correlationbetweenocularperfusionpressureandocularpulseamplitudeinglaucomaocularhypertensionandnormaleyes
AT kanadanifabion correlationbetweenocularperfusionpressureandocularpulseamplitudeinglaucomaocularhypertensionandnormaleyes