Cargando…

Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications

A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed o...

Descripción completa

Detalles Bibliográficos
Autores principales: Vijaya Bhaskar, V., Middha, Anil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745871/
https://www.ncbi.nlm.nih.gov/pubmed/23983693
http://dx.doi.org/10.1155/2013/135613
_version_ 1782280747940315136
author Vijaya Bhaskar, V.
Middha, Anil
author_facet Vijaya Bhaskar, V.
Middha, Anil
author_sort Vijaya Bhaskar, V.
collection PubMed
description A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (XBridge, 50 × 4.6 mm, 3.5 μm). The most abundant molecular ions corresponding to PEG oligomers at m/z 828, 872, 916 and 960 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Plasma concentrations of CrEL were quantified after administration through oral and intravenous routes in male sprague dawley rats at a dose of 0.26 g/kg. The standard curve was linear (0.9972) over the concentration range of 1.00 to 200 μg/mL. The lower limit of quantitation for CrEL was 1.00 μg/mL using 50 μL plasma. The coefficient of variation and relative error for inter and intra assay at three QC levels were 0.69 to 9.21 and −7.60 to 4.74 respectively. A novel proposal was conveyed to the scientific community, where formulation excipient can be analysed as qualifier in the analysis of NCEs to address the spiky plasma concentration profiles.
format Online
Article
Text
id pubmed-3745871
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37458712013-08-27 Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications Vijaya Bhaskar, V. Middha, Anil Int J Anal Chem Research Article A rapid sensitive and selective MRM based method for the determination of Cremophor EL (CrEL) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). CrEL and polypropylene glycol (internal standard) were extracted from rat plasma with acetonitrile and analysed on C18 column (XBridge, 50 × 4.6 mm, 3.5 μm). The most abundant molecular ions corresponding to PEG oligomers at m/z 828, 872, 916 and 960 with daughter ion at m/z 89 were selected for multiple reaction monitoring (MRM) in electrospray mode of ionisation. Plasma concentrations of CrEL were quantified after administration through oral and intravenous routes in male sprague dawley rats at a dose of 0.26 g/kg. The standard curve was linear (0.9972) over the concentration range of 1.00 to 200 μg/mL. The lower limit of quantitation for CrEL was 1.00 μg/mL using 50 μL plasma. The coefficient of variation and relative error for inter and intra assay at three QC levels were 0.69 to 9.21 and −7.60 to 4.74 respectively. A novel proposal was conveyed to the scientific community, where formulation excipient can be analysed as qualifier in the analysis of NCEs to address the spiky plasma concentration profiles. Hindawi Publishing Corporation 2013 2013-07-28 /pmc/articles/PMC3745871/ /pubmed/23983693 http://dx.doi.org/10.1155/2013/135613 Text en Copyright © 2013 V. Vijaya Bhaskar and A. Middha. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Vijaya Bhaskar, V.
Middha, Anil
Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_full Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_fullStr Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_full_unstemmed Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_short Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitation of Cremophor EL and Its Applications
title_sort liquid chromatography/tandem mass spectrometry method for quantitation of cremophor el and its applications
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745871/
https://www.ncbi.nlm.nih.gov/pubmed/23983693
http://dx.doi.org/10.1155/2013/135613
work_keys_str_mv AT vijayabhaskarv liquidchromatographytandemmassspectrometrymethodforquantitationofcremophorelanditsapplications
AT middhaanil liquidchromatographytandemmassspectrometrymethodforquantitationofcremophorelanditsapplications