Cargando…
Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?
Purpose. This study examines the effects of fundus fluorescein angiography (FFA) procedure on ocular pulse amplitude (OPA) and intraocular pressure (IOP). Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females) were included in this cross-section...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745956/ https://www.ncbi.nlm.nih.gov/pubmed/23984045 http://dx.doi.org/10.1155/2013/942972 |
_version_ | 1782280767379865600 |
---|---|
author | Pekel, Gökhan Acer, Semra Yagci, Ramazan Cetin, Ebru Nevin Hiraali, Mehmet Can Kaya, Hüseyin |
author_facet | Pekel, Gökhan Acer, Semra Yagci, Ramazan Cetin, Ebru Nevin Hiraali, Mehmet Can Kaya, Hüseyin |
author_sort | Pekel, Gökhan |
collection | PubMed |
description | Purpose. This study examines the effects of fundus fluorescein angiography (FFA) procedure on ocular pulse amplitude (OPA) and intraocular pressure (IOP). Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females) were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was 3.05 ± 1.36 mmHg and post-FFA mean OPA value was 2.93 ± 1.28 mmHg (P = 0.071). Pre-FFA mean IOP value was 17.97 ± 1.99 mmHg and post-FFA mean IOP value was 17.81 ± 2.22 mmHg (P = 0.407). Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707. |
format | Online Article Text |
id | pubmed-3745956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-37459562013-08-27 Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? Pekel, Gökhan Acer, Semra Yagci, Ramazan Cetin, Ebru Nevin Hiraali, Mehmet Can Kaya, Hüseyin J Ophthalmol Clinical Study Purpose. This study examines the effects of fundus fluorescein angiography (FFA) procedure on ocular pulse amplitude (OPA) and intraocular pressure (IOP). Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females) were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was 3.05 ± 1.36 mmHg and post-FFA mean OPA value was 2.93 ± 1.28 mmHg (P = 0.071). Pre-FFA mean IOP value was 17.97 ± 1.99 mmHg and post-FFA mean IOP value was 17.81 ± 2.22 mmHg (P = 0.407). Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707. Hindawi Publishing Corporation 2013 2013-07-30 /pmc/articles/PMC3745956/ /pubmed/23984045 http://dx.doi.org/10.1155/2013/942972 Text en Copyright © 2013 Gökhan Pekel et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Pekel, Gökhan Acer, Semra Yagci, Ramazan Cetin, Ebru Nevin Hiraali, Mehmet Can Kaya, Hüseyin Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title | Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title_full | Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title_fullStr | Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title_full_unstemmed | Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title_short | Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude? |
title_sort | does fundus fluorescein angiography procedure affect ocular pulse amplitude? |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745956/ https://www.ncbi.nlm.nih.gov/pubmed/23984045 http://dx.doi.org/10.1155/2013/942972 |
work_keys_str_mv | AT pekelgokhan doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude AT acersemra doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude AT yagciramazan doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude AT cetinebrunevin doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude AT hiraalimehmetcan doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude AT kayahuseyin doesfundusfluoresceinangiographyprocedureaffectocularpulseamplitude |