Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software

Purpose. To compare the number of image acquisitions and procedural time required for transarterial chemoembolization (TACE) with and without tumor-feeder detection software in cases of hepatocellular carcinoma (HCC). Materials and Methods. We retrospectively reviewed 50 cases involving software-ass...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwazawa, Jin, Ohue, Shoichi, Hashimoto, Naoko, Mitani, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745970/
https://www.ncbi.nlm.nih.gov/pubmed/23984066
http://dx.doi.org/10.1155/2013/580839
_version_ 1782280770556002304
author Iwazawa, Jin
Ohue, Shoichi
Hashimoto, Naoko
Mitani, Takashi
author_facet Iwazawa, Jin
Ohue, Shoichi
Hashimoto, Naoko
Mitani, Takashi
author_sort Iwazawa, Jin
collection PubMed
description Purpose. To compare the number of image acquisitions and procedural time required for transarterial chemoembolization (TACE) with and without tumor-feeder detection software in cases of hepatocellular carcinoma (HCC). Materials and Methods. We retrospectively reviewed 50 cases involving software-assisted TACE (September 2011–February 2013) and 84 cases involving TACE without software assistance (January 2010–August 2011). We compared the number of image acquisitions, the overall procedural time, and the therapeutic efficacy in both groups. Results. Angiography acquisition per session reduced from 6.6 times to 4.6 times with software assistance (P < 0.001). Total image acquisition significantly decreased from 10.4 times to 8.7 times with software usage (P = 0.004). The mean procedural time required for a single session with software-assisted TACE (103 min) was significantly lower than that for a session without software (116 min, P = 0.021). For TACE with and without software usage, the complete (68% versus 63%, resp.) and objective (78% versus 80%, resp.) response rates did not differ significantly. Conclusion. In comparison with software-unassisted TACE, automated feeder-vessel detection software-assisted TACE for HCC involved fewer image acquisitions and could be completed faster while maintaining a comparable treatment response.
format Online
Article
Text
id pubmed-3745970
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37459702013-08-27 Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software Iwazawa, Jin Ohue, Shoichi Hashimoto, Naoko Mitani, Takashi Radiol Res Pract Clinical Study Purpose. To compare the number of image acquisitions and procedural time required for transarterial chemoembolization (TACE) with and without tumor-feeder detection software in cases of hepatocellular carcinoma (HCC). Materials and Methods. We retrospectively reviewed 50 cases involving software-assisted TACE (September 2011–February 2013) and 84 cases involving TACE without software assistance (January 2010–August 2011). We compared the number of image acquisitions, the overall procedural time, and the therapeutic efficacy in both groups. Results. Angiography acquisition per session reduced from 6.6 times to 4.6 times with software assistance (P < 0.001). Total image acquisition significantly decreased from 10.4 times to 8.7 times with software usage (P = 0.004). The mean procedural time required for a single session with software-assisted TACE (103 min) was significantly lower than that for a session without software (116 min, P = 0.021). For TACE with and without software usage, the complete (68% versus 63%, resp.) and objective (78% versus 80%, resp.) response rates did not differ significantly. Conclusion. In comparison with software-unassisted TACE, automated feeder-vessel detection software-assisted TACE for HCC involved fewer image acquisitions and could be completed faster while maintaining a comparable treatment response. Hindawi Publishing Corporation 2013 2013-07-29 /pmc/articles/PMC3745970/ /pubmed/23984066 http://dx.doi.org/10.1155/2013/580839 Text en Copyright © 2013 Jin Iwazawa et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Iwazawa, Jin
Ohue, Shoichi
Hashimoto, Naoko
Mitani, Takashi
Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title_full Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title_fullStr Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title_full_unstemmed Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title_short Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software
title_sort comparison of the number of image acquisitions and procedural time required for transarterial chemoembolization of hepatocellular carcinoma with and without tumor-feeder detection software
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745970/
https://www.ncbi.nlm.nih.gov/pubmed/23984066
http://dx.doi.org/10.1155/2013/580839
work_keys_str_mv AT iwazawajin comparisonofthenumberofimageacquisitionsandproceduraltimerequiredfortransarterialchemoembolizationofhepatocellularcarcinomawithandwithouttumorfeederdetectionsoftware
AT ohueshoichi comparisonofthenumberofimageacquisitionsandproceduraltimerequiredfortransarterialchemoembolizationofhepatocellularcarcinomawithandwithouttumorfeederdetectionsoftware
AT hashimotonaoko comparisonofthenumberofimageacquisitionsandproceduraltimerequiredfortransarterialchemoembolizationofhepatocellularcarcinomawithandwithouttumorfeederdetectionsoftware
AT mitanitakashi comparisonofthenumberofimageacquisitionsandproceduraltimerequiredfortransarterialchemoembolizationofhepatocellularcarcinomawithandwithouttumorfeederdetectionsoftware