Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming
Placement of a self-expanding metal stent (SEMS) is an effective method for palliation of a malignant biliary obstruction. However, metal stents can cause various complications, including stent migration. Distally migrated metal stents, particularly covered SEMS, can be removed successfully in most...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Gastrointestinal Endoscopy
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3746152/ https://www.ncbi.nlm.nih.gov/pubmed/23964344 http://dx.doi.org/10.5946/ce.2013.46.4.418 |
_version_ | 1782280800916471808 |
---|---|
author | Cho, Nam Jun Lee, Tae Hoon Park, Sang-Heum Lee, Han Min Hyun, Kyung Hee Lee, Suck-Ho Chung, Il-Kwun Kim, Sun-Joo |
author_facet | Cho, Nam Jun Lee, Tae Hoon Park, Sang-Heum Lee, Han Min Hyun, Kyung Hee Lee, Suck-Ho Chung, Il-Kwun Kim, Sun-Joo |
author_sort | Cho, Nam Jun |
collection | PubMed |
description | Placement of a self-expanding metal stent (SEMS) is an effective method for palliation of a malignant biliary obstruction. However, metal stents can cause various complications, including stent migration. Distally migrated metal stents, particularly covered SEMS, can be removed successfully in most cases. Stent trimming using argon plasma coagulation may be helpful in difficult cases despite conventional methods. However, no serious complications related to the trimming or remnant stent removal method have been reported due to the limited number of cases. In particular, proximal migration of a remnant fragmented metal stent after stent trimming followed by balloon sweeping has not been reported. We report an unusual case of proximal migration of a remnant metal stent during balloon sweeping following stent trimming by argon plasma coagulation. The remnant metal stent was successfully removed with rotation technique using a basket and revised endoscopically. |
format | Online Article Text |
id | pubmed-3746152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Society of Gastrointestinal Endoscopy |
record_format | MEDLINE/PubMed |
spelling | pubmed-37461522013-08-20 Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming Cho, Nam Jun Lee, Tae Hoon Park, Sang-Heum Lee, Han Min Hyun, Kyung Hee Lee, Suck-Ho Chung, Il-Kwun Kim, Sun-Joo Clin Endosc Case Report Placement of a self-expanding metal stent (SEMS) is an effective method for palliation of a malignant biliary obstruction. However, metal stents can cause various complications, including stent migration. Distally migrated metal stents, particularly covered SEMS, can be removed successfully in most cases. Stent trimming using argon plasma coagulation may be helpful in difficult cases despite conventional methods. However, no serious complications related to the trimming or remnant stent removal method have been reported due to the limited number of cases. In particular, proximal migration of a remnant fragmented metal stent after stent trimming followed by balloon sweeping has not been reported. We report an unusual case of proximal migration of a remnant metal stent during balloon sweeping following stent trimming by argon plasma coagulation. The remnant metal stent was successfully removed with rotation technique using a basket and revised endoscopically. The Korean Society of Gastrointestinal Endoscopy 2013-07 2013-07-31 /pmc/articles/PMC3746152/ /pubmed/23964344 http://dx.doi.org/10.5946/ce.2013.46.4.418 Text en Copyright © 2013 Korean Society of Gastrointestinal Endoscopy http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Cho, Nam Jun Lee, Tae Hoon Park, Sang-Heum Lee, Han Min Hyun, Kyung Hee Lee, Suck-Ho Chung, Il-Kwun Kim, Sun-Joo Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title | Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title_full | Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title_fullStr | Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title_full_unstemmed | Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title_short | Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming |
title_sort | endoscopic removal of a proximally migrated metal stent during balloon sweeping after stent trimming |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3746152/ https://www.ncbi.nlm.nih.gov/pubmed/23964344 http://dx.doi.org/10.5946/ce.2013.46.4.418 |
work_keys_str_mv | AT chonamjun endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT leetaehoon endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT parksangheum endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT leehanmin endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT hyunkyunghee endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT leesuckho endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT chungilkwun endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming AT kimsunjoo endoscopicremovalofaproximallymigratedmetalstentduringballoonsweepingafterstenttrimming |