In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension

From an engineering standpoint, both the skin and subcutaneous tissue act as interconnected load-transmitting structures. They are subject to a variety of intrinsic and environmental influences. Changes in the cutaneous viscoelasticity represent an important aspect in a series of skin conditions. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Piérard, Gérald E., Piérard, Sébastien, Delvenne, Philippe, Piérard-Franchimont, Claudine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3748421/
https://www.ncbi.nlm.nih.gov/pubmed/23986871
http://dx.doi.org/10.1155/2013/841217
_version_ 1782281064603975680
author Piérard, Gérald E.
Piérard, Sébastien
Delvenne, Philippe
Piérard-Franchimont, Claudine
author_facet Piérard, Gérald E.
Piérard, Sébastien
Delvenne, Philippe
Piérard-Franchimont, Claudine
author_sort Piérard, Gérald E.
collection PubMed
description From an engineering standpoint, both the skin and subcutaneous tissue act as interconnected load-transmitting structures. They are subject to a variety of intrinsic and environmental influences. Changes in the cutaneous viscoelasticity represent an important aspect in a series of skin conditions. The aim of this work was to explore the methodology of biomechanical measurements in order to better appreciate the evolution and severity of some connective tissue diseases. The Cutometer MPA 580 (C+K electronic) was used in the steep and progressive suction procedures. Adapting measurement modalities was explored in order to mitigate any variability in data collection. The repeat steep suction procedure conveniently reveals the creep phenomenon. By contrast, the progressive suction procedure highlights the hysteresis phenomenon. These viscoelastic characteristics are presently described using the 2 and 4 mm probes on normal skin and in scleroderma, acromegaly, corticosteroid-induced dermatoporosis, and Ehlers-Danlos syndrome. The apposition of an additional outer contention on the skin altered differently the manifestations of the creep extension and hysteresis among the tested skin conditions. Any change in the mechanical test procedure affects the data. In clinical and experimental settings, it is mandatory to adhere to a strict and controlled protocol.
format Online
Article
Text
id pubmed-3748421
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37484212013-08-28 In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension Piérard, Gérald E. Piérard, Sébastien Delvenne, Philippe Piérard-Franchimont, Claudine ISRN Dermatol Clinical Study From an engineering standpoint, both the skin and subcutaneous tissue act as interconnected load-transmitting structures. They are subject to a variety of intrinsic and environmental influences. Changes in the cutaneous viscoelasticity represent an important aspect in a series of skin conditions. The aim of this work was to explore the methodology of biomechanical measurements in order to better appreciate the evolution and severity of some connective tissue diseases. The Cutometer MPA 580 (C+K electronic) was used in the steep and progressive suction procedures. Adapting measurement modalities was explored in order to mitigate any variability in data collection. The repeat steep suction procedure conveniently reveals the creep phenomenon. By contrast, the progressive suction procedure highlights the hysteresis phenomenon. These viscoelastic characteristics are presently described using the 2 and 4 mm probes on normal skin and in scleroderma, acromegaly, corticosteroid-induced dermatoporosis, and Ehlers-Danlos syndrome. The apposition of an additional outer contention on the skin altered differently the manifestations of the creep extension and hysteresis among the tested skin conditions. Any change in the mechanical test procedure affects the data. In clinical and experimental settings, it is mandatory to adhere to a strict and controlled protocol. Hindawi Publishing Corporation 2013-08-05 /pmc/articles/PMC3748421/ /pubmed/23986871 http://dx.doi.org/10.1155/2013/841217 Text en Copyright © 2013 Gérald E. Piérard et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Piérard, Gérald E.
Piérard, Sébastien
Delvenne, Philippe
Piérard-Franchimont, Claudine
In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title_full In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title_fullStr In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title_full_unstemmed In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title_short In Vivo Evaluation of the Skin Tensile Strength by the Suction Method: Pilot Study Coping with Hysteresis and Creep Extension
title_sort in vivo evaluation of the skin tensile strength by the suction method: pilot study coping with hysteresis and creep extension
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3748421/
https://www.ncbi.nlm.nih.gov/pubmed/23986871
http://dx.doi.org/10.1155/2013/841217
work_keys_str_mv AT pierardgeralde invivoevaluationoftheskintensilestrengthbythesuctionmethodpilotstudycopingwithhysteresisandcreepextension
AT pierardsebastien invivoevaluationoftheskintensilestrengthbythesuctionmethodpilotstudycopingwithhysteresisandcreepextension
AT delvennephilippe invivoevaluationoftheskintensilestrengthbythesuctionmethodpilotstudycopingwithhysteresisandcreepextension
AT pierardfranchimontclaudine invivoevaluationoftheskintensilestrengthbythesuctionmethodpilotstudycopingwithhysteresisandcreepextension