Cargando…

A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario

BACKGROUND: In biomedical research, a huge variety of different techniques is currently available for the structural examination of small specimens, including conventional light microscopy (LM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM), microscopic X-ray comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Handschuh, Stephan, Baeumler, Natalie, Schwaha, Thomas, Ruthensteiner, Bernhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3750762/
https://www.ncbi.nlm.nih.gov/pubmed/23915384
http://dx.doi.org/10.1186/1742-9994-10-44
_version_ 1782281475621650432
author Handschuh, Stephan
Baeumler, Natalie
Schwaha, Thomas
Ruthensteiner, Bernhard
author_facet Handschuh, Stephan
Baeumler, Natalie
Schwaha, Thomas
Ruthensteiner, Bernhard
author_sort Handschuh, Stephan
collection PubMed
description BACKGROUND: In biomedical research, a huge variety of different techniques is currently available for the structural examination of small specimens, including conventional light microscopy (LM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM), microscopic X-ray computed tomography (microCT), and many others. Since every imaging method is physically limited by certain parameters, a correlative use of complementary methods often yields a significant broader range of information. Here we demonstrate the advantages of the correlative use of microCT, light microscopy, and transmission electron microscopy for the analysis of small biological samples. RESULTS: We used a small juvenile bivalve mollusc (Mytilus galloprovincialis, approximately 0.8 mm length) to demonstrate the workflow of a correlative examination by microCT, LM serial section analysis, and TEM-re-sectioning. Initially these three datasets were analyzed separately, and subsequently they were fused in one 3D scene. This workflow is very straightforward. The specimen was processed as usual for transmission electron microscopy including post-fixation in osmium tetroxide and embedding in epoxy resin. Subsequently it was imaged with microCT. Post-fixation in osmium tetroxide yielded sufficient X-ray contrast for microCT imaging, since the X-ray absorption of epoxy resin is low. Thereafter, the same specimen was serially sectioned for LM investigation. The serial section images were aligned and specific organ systems were reconstructed based on manual segmentation and surface rendering. According to the region of interest (ROI), specific LM sections were detached from the slides, re-mounted on resin blocks and re-sectioned (ultrathin) for TEM. For analysis, image data from the three different modalities was co-registered into a single 3D scene using the software AMIRA®. We were able to register both the LM section series volume and TEM slices neatly to the microCT dataset, with small geometric deviations occurring only in the peripheral areas of the specimen. Based on co-registered datasets the excretory organs, which were chosen as ROI for this study, could be investigated regarding both their ultrastructure as well as their position in the organism and their spatial relationship to adjacent tissues. We found structures typical for mollusc excretory systems, including ultrafiltration sites at the pericardial wall, and ducts leading from the pericardium towards the kidneys, which exhibit a typical basal infolding system. CONCLUSIONS: The presented approach allows a comprehensive analysis and presentation of small objects regarding both the overall organization as well as cellular and subcellular details. Although our protocol involves a variety of different equipment and procedures, we maintain that it offers savings in both effort and cost. Co-registration of datasets from different imaging modalities can be accomplished with high-end desktop computers and offers new opportunities for understanding and communicating structural relationships within organisms and tissues. In general, the correlative use of different microscopic imaging techniques will continue to become more widespread in morphological and structural research in zoology. Classical TEM serial section investigations are extremely time consuming, and modern methods for 3D analysis of ultrastructure such as SBF-SEM and FIB-SEM are limited to very small volumes for examination. Thus the re-sectioning of LM sections is suitable for speeding up TEM examination substantially, while microCT could become a key-method for complementing ultrastructural examinations.
format Online
Article
Text
id pubmed-3750762
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37507622013-08-24 A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario Handschuh, Stephan Baeumler, Natalie Schwaha, Thomas Ruthensteiner, Bernhard Front Zool Methodology BACKGROUND: In biomedical research, a huge variety of different techniques is currently available for the structural examination of small specimens, including conventional light microscopy (LM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM), microscopic X-ray computed tomography (microCT), and many others. Since every imaging method is physically limited by certain parameters, a correlative use of complementary methods often yields a significant broader range of information. Here we demonstrate the advantages of the correlative use of microCT, light microscopy, and transmission electron microscopy for the analysis of small biological samples. RESULTS: We used a small juvenile bivalve mollusc (Mytilus galloprovincialis, approximately 0.8 mm length) to demonstrate the workflow of a correlative examination by microCT, LM serial section analysis, and TEM-re-sectioning. Initially these three datasets were analyzed separately, and subsequently they were fused in one 3D scene. This workflow is very straightforward. The specimen was processed as usual for transmission electron microscopy including post-fixation in osmium tetroxide and embedding in epoxy resin. Subsequently it was imaged with microCT. Post-fixation in osmium tetroxide yielded sufficient X-ray contrast for microCT imaging, since the X-ray absorption of epoxy resin is low. Thereafter, the same specimen was serially sectioned for LM investigation. The serial section images were aligned and specific organ systems were reconstructed based on manual segmentation and surface rendering. According to the region of interest (ROI), specific LM sections were detached from the slides, re-mounted on resin blocks and re-sectioned (ultrathin) for TEM. For analysis, image data from the three different modalities was co-registered into a single 3D scene using the software AMIRA®. We were able to register both the LM section series volume and TEM slices neatly to the microCT dataset, with small geometric deviations occurring only in the peripheral areas of the specimen. Based on co-registered datasets the excretory organs, which were chosen as ROI for this study, could be investigated regarding both their ultrastructure as well as their position in the organism and their spatial relationship to adjacent tissues. We found structures typical for mollusc excretory systems, including ultrafiltration sites at the pericardial wall, and ducts leading from the pericardium towards the kidneys, which exhibit a typical basal infolding system. CONCLUSIONS: The presented approach allows a comprehensive analysis and presentation of small objects regarding both the overall organization as well as cellular and subcellular details. Although our protocol involves a variety of different equipment and procedures, we maintain that it offers savings in both effort and cost. Co-registration of datasets from different imaging modalities can be accomplished with high-end desktop computers and offers new opportunities for understanding and communicating structural relationships within organisms and tissues. In general, the correlative use of different microscopic imaging techniques will continue to become more widespread in morphological and structural research in zoology. Classical TEM serial section investigations are extremely time consuming, and modern methods for 3D analysis of ultrastructure such as SBF-SEM and FIB-SEM are limited to very small volumes for examination. Thus the re-sectioning of LM sections is suitable for speeding up TEM examination substantially, while microCT could become a key-method for complementing ultrastructural examinations. BioMed Central 2013-08-03 /pmc/articles/PMC3750762/ /pubmed/23915384 http://dx.doi.org/10.1186/1742-9994-10-44 Text en Copyright © 2013 Handschuh et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Handschuh, Stephan
Baeumler, Natalie
Schwaha, Thomas
Ruthensteiner, Bernhard
A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title_full A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title_fullStr A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title_full_unstemmed A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title_short A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario
title_sort correlative approach for combining microct, light and transmission electron microscopy in a single 3d scenario
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3750762/
https://www.ncbi.nlm.nih.gov/pubmed/23915384
http://dx.doi.org/10.1186/1742-9994-10-44
work_keys_str_mv AT handschuhstephan acorrelativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT baeumlernatalie acorrelativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT schwahathomas acorrelativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT ruthensteinerbernhard acorrelativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT handschuhstephan correlativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT baeumlernatalie correlativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT schwahathomas correlativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario
AT ruthensteinerbernhard correlativeapproachforcombiningmicroctlightandtransmissionelectronmicroscopyinasingle3dscenario