A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans

BACKGROUND: The modulated arc (mARC) technique has recently been introduced by Siemens as an analogue to VMAT treatment. However, up to now only one certified treatment planning system supports mARC planning. We therefore present a conversion algorithm capable of converting IMRT plans created by any...

Descripción completa

Detalles Bibliográficos
Autores principales: Dzierma, Yvonne, Nuesken, Frank, Licht, Norbert, Ruebe, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3750816/
https://www.ncbi.nlm.nih.gov/pubmed/23915350
http://dx.doi.org/10.1186/1748-717X-8-193
_version_ 1782281479310540800
author Dzierma, Yvonne
Nuesken, Frank
Licht, Norbert
Ruebe, Christian
author_facet Dzierma, Yvonne
Nuesken, Frank
Licht, Norbert
Ruebe, Christian
author_sort Dzierma, Yvonne
collection PubMed
description BACKGROUND: The modulated arc (mARC) technique has recently been introduced by Siemens as an analogue to VMAT treatment. However, up to now only one certified treatment planning system supports mARC planning. We therefore present a conversion algorithm capable of converting IMRT plans created by any treatment planning system into mARC plans, with the hope of expanding the availability of mARC to a larger range of clinical users and researchers. As additional advantages, our implementation offers improved functionality for planning hybrid arcs and provides an equivalent step-and-shoot plan for each mARC plan, which can be used as a back-up concept in institutions where only one linac is equipped with mARC. METHODS: We present a feasibility study to outline a practical implementation of mARC plan conversion using Philips Pinnacle and Prowess Panther. We present examples for three different kinds of prostate and head-and-neck plans, for 6 MV and flattening-filter-free (FFF) 7 MV photon energies, which are dosimetrically verified. RESULTS: It is generally more difficult to create good quality IMRT plans in Pinnacle using a large number of beams and few segments. We present different ways of optimization as examples. By careful choosing the beam and segment arrangement and inversion objectives, we achieve plan qualities similar to our usual IMRT plans. The conversion of the plans to mARC format yields functional plans, which can be irradiated without incidences. Absolute dosimetric verification of both the step-and-shoot and mARC plans by point dose measurements showed deviations below 5% local dose, mARC plans deviated from step-and-shoot plans by no more than 1%. The agreement between GafChromic film measurements of planar dose before and after mARC conversion is excellent. The comparison of the 3D dose distribution measured by PTW Octavius 729 2D-Array with the step-and-shoot plans and with the TPS is well above the pass criteria of 90% of the points falling within 5% local dose and 3 mm distance to agreement. For all plans, the treatment time was noticeably reduced by conversion to mARC. CONCLUSIONS: We present the feasibility test for converting IMRT step-and-shoot plans from the RTP-output of any treatment planning system (Philips Pinnacle and Prowess Panther, in our case) into mARC plans. The feasibility and dosimetric equivalence is demonstrated for the examples of a prostate and a head-and-neck patient.
format Online
Article
Text
id pubmed-3750816
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37508162013-08-24 A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans Dzierma, Yvonne Nuesken, Frank Licht, Norbert Ruebe, Christian Radiat Oncol Research BACKGROUND: The modulated arc (mARC) technique has recently been introduced by Siemens as an analogue to VMAT treatment. However, up to now only one certified treatment planning system supports mARC planning. We therefore present a conversion algorithm capable of converting IMRT plans created by any treatment planning system into mARC plans, with the hope of expanding the availability of mARC to a larger range of clinical users and researchers. As additional advantages, our implementation offers improved functionality for planning hybrid arcs and provides an equivalent step-and-shoot plan for each mARC plan, which can be used as a back-up concept in institutions where only one linac is equipped with mARC. METHODS: We present a feasibility study to outline a practical implementation of mARC plan conversion using Philips Pinnacle and Prowess Panther. We present examples for three different kinds of prostate and head-and-neck plans, for 6 MV and flattening-filter-free (FFF) 7 MV photon energies, which are dosimetrically verified. RESULTS: It is generally more difficult to create good quality IMRT plans in Pinnacle using a large number of beams and few segments. We present different ways of optimization as examples. By careful choosing the beam and segment arrangement and inversion objectives, we achieve plan qualities similar to our usual IMRT plans. The conversion of the plans to mARC format yields functional plans, which can be irradiated without incidences. Absolute dosimetric verification of both the step-and-shoot and mARC plans by point dose measurements showed deviations below 5% local dose, mARC plans deviated from step-and-shoot plans by no more than 1%. The agreement between GafChromic film measurements of planar dose before and after mARC conversion is excellent. The comparison of the 3D dose distribution measured by PTW Octavius 729 2D-Array with the step-and-shoot plans and with the TPS is well above the pass criteria of 90% of the points falling within 5% local dose and 3 mm distance to agreement. For all plans, the treatment time was noticeably reduced by conversion to mARC. CONCLUSIONS: We present the feasibility test for converting IMRT step-and-shoot plans from the RTP-output of any treatment planning system (Philips Pinnacle and Prowess Panther, in our case) into mARC plans. The feasibility and dosimetric equivalence is demonstrated for the examples of a prostate and a head-and-neck patient. BioMed Central 2013-08-03 /pmc/articles/PMC3750816/ /pubmed/23915350 http://dx.doi.org/10.1186/1748-717X-8-193 Text en Copyright © 2013 Dzierma et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Dzierma, Yvonne
Nuesken, Frank
Licht, Norbert
Ruebe, Christian
A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title_full A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title_fullStr A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title_full_unstemmed A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title_short A novel implementation of mARC treatment for non-dedicated planning systems using converted IMRT plans
title_sort novel implementation of marc treatment for non-dedicated planning systems using converted imrt plans
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3750816/
https://www.ncbi.nlm.nih.gov/pubmed/23915350
http://dx.doi.org/10.1186/1748-717X-8-193
work_keys_str_mv AT dziermayvonne anovelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT nueskenfrank anovelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT lichtnorbert anovelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT ruebechristian anovelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT dziermayvonne novelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT nueskenfrank novelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT lichtnorbert novelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans
AT ruebechristian novelimplementationofmarctreatmentfornondedicatedplanningsystemsusingconvertedimrtplans