Cargando…

Monitoring motor capacity changes of children during rehabilitation using body-worn sensors

BACKGROUND: Rehabilitation services use outcome measures to track motor performance of their patients over time. State-of-the-art approaches use mainly patients’ feedback and experts’ observations for this purpose. We aim at continuously monitoring children in daily life and assessing normal activit...

Descripción completa

Detalles Bibliográficos
Autores principales: Strohrmann, Christina, Labruyère, Rob, Gerber, Corinna N, van Hedel, Hubertus J, Arnrich, Bert, Tröster, Gerhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3751753/
https://www.ncbi.nlm.nih.gov/pubmed/23899401
http://dx.doi.org/10.1186/1743-0003-10-83
_version_ 1782281661887545344
author Strohrmann, Christina
Labruyère, Rob
Gerber, Corinna N
van Hedel, Hubertus J
Arnrich, Bert
Tröster, Gerhard
author_facet Strohrmann, Christina
Labruyère, Rob
Gerber, Corinna N
van Hedel, Hubertus J
Arnrich, Bert
Tröster, Gerhard
author_sort Strohrmann, Christina
collection PubMed
description BACKGROUND: Rehabilitation services use outcome measures to track motor performance of their patients over time. State-of-the-art approaches use mainly patients’ feedback and experts’ observations for this purpose. We aim at continuously monitoring children in daily life and assessing normal activities to close the gap between movements done as instructed by caregivers and natural movements during daily life. To investigate the applicability of body-worn sensors for motor assessment in children, we investigated changes in movement capacity during defined motor tasks longitudinally. METHODS: We performed a longitudinal study over four weeks with 4 children (2 girls; 2 diagnosed with Cerebral Palsy and 2 with stroke, on average 10.5 years old) undergoing rehabilitation. Every week, the children performed 10 predefined motor tasks. Capacity in terms of quality and quantity was assessed by experts and movement was monitored using 10 ETH Orientation Sensors (ETHOS), a small and unobtrusive inertial measurement unit. Features such as smoothness of movement were calculated from the sensor data and a regression was used to estimate the capacity from the features and their relation to clinical data. Therefore, the target and features were normalized to range from 0 to 1. RESULTS: We achieved a mean RMS-error of 0.15 and a mean correlation value of 0.86 (p<0.05 for all tasks) between our regression estimate of motor task capacity and experts’ ratings across all tasks. We identified the most important features and were able to reduce the sensor setup from 10 to 3 sensors. We investigated features that provided a good estimate of the motor capacity independently of the task performed, e.g. smoothness of the movement. CONCLUSIONS: We found that children’s task capacity can be assessed from wearable sensors and that some of the calculated features provide a good estimate of movement capacity over different tasks. This indicates the potential of using the sensors in daily life, when little or no information on the task performed is available. For the assessment, the use of three sensors on both wrists and the hip suffices. With the developed algorithms, we plan to assess children’s motor performance in daily life with a follow-up study.
format Online
Article
Text
id pubmed-3751753
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37517532013-08-28 Monitoring motor capacity changes of children during rehabilitation using body-worn sensors Strohrmann, Christina Labruyère, Rob Gerber, Corinna N van Hedel, Hubertus J Arnrich, Bert Tröster, Gerhard J Neuroeng Rehabil Research BACKGROUND: Rehabilitation services use outcome measures to track motor performance of their patients over time. State-of-the-art approaches use mainly patients’ feedback and experts’ observations for this purpose. We aim at continuously monitoring children in daily life and assessing normal activities to close the gap between movements done as instructed by caregivers and natural movements during daily life. To investigate the applicability of body-worn sensors for motor assessment in children, we investigated changes in movement capacity during defined motor tasks longitudinally. METHODS: We performed a longitudinal study over four weeks with 4 children (2 girls; 2 diagnosed with Cerebral Palsy and 2 with stroke, on average 10.5 years old) undergoing rehabilitation. Every week, the children performed 10 predefined motor tasks. Capacity in terms of quality and quantity was assessed by experts and movement was monitored using 10 ETH Orientation Sensors (ETHOS), a small and unobtrusive inertial measurement unit. Features such as smoothness of movement were calculated from the sensor data and a regression was used to estimate the capacity from the features and their relation to clinical data. Therefore, the target and features were normalized to range from 0 to 1. RESULTS: We achieved a mean RMS-error of 0.15 and a mean correlation value of 0.86 (p<0.05 for all tasks) between our regression estimate of motor task capacity and experts’ ratings across all tasks. We identified the most important features and were able to reduce the sensor setup from 10 to 3 sensors. We investigated features that provided a good estimate of the motor capacity independently of the task performed, e.g. smoothness of the movement. CONCLUSIONS: We found that children’s task capacity can be assessed from wearable sensors and that some of the calculated features provide a good estimate of movement capacity over different tasks. This indicates the potential of using the sensors in daily life, when little or no information on the task performed is available. For the assessment, the use of three sensors on both wrists and the hip suffices. With the developed algorithms, we plan to assess children’s motor performance in daily life with a follow-up study. BioMed Central 2013-07-30 /pmc/articles/PMC3751753/ /pubmed/23899401 http://dx.doi.org/10.1186/1743-0003-10-83 Text en Copyright © 2013 Strohrmann et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Strohrmann, Christina
Labruyère, Rob
Gerber, Corinna N
van Hedel, Hubertus J
Arnrich, Bert
Tröster, Gerhard
Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title_full Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title_fullStr Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title_full_unstemmed Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title_short Monitoring motor capacity changes of children during rehabilitation using body-worn sensors
title_sort monitoring motor capacity changes of children during rehabilitation using body-worn sensors
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3751753/
https://www.ncbi.nlm.nih.gov/pubmed/23899401
http://dx.doi.org/10.1186/1743-0003-10-83
work_keys_str_mv AT strohrmannchristina monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors
AT labruyererob monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors
AT gerbercorinnan monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors
AT vanhedelhubertusj monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors
AT arnrichbert monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors
AT trostergerhard monitoringmotorcapacitychangesofchildrenduringrehabilitationusingbodywornsensors