Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation

A high cell density perfusion process of monoclonal antibody (MAb) producing Chinese hamster ovary (CHO) cells was developed in disposable WAVE Bioreactor™ using external hollow fiber (HF) filter as cell separation device. Tangential flow filtration (TFF) and alternating tangential flow (ATF) system...

Descripción completa

Detalles Bibliográficos
Autores principales: Clincke, Marie-Françoise, Mölleryd, Carin, Samani, Puneeth K, Lindskog, Eva, Fäldt, Eric, Walsh, Kieron, Chotteau, Véronique
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3752935/
https://www.ncbi.nlm.nih.gov/pubmed/23436783
http://dx.doi.org/10.1002/btpr.1703
_version_ 1782281772461981696
author Clincke, Marie-Françoise
Mölleryd, Carin
Samani, Puneeth K
Lindskog, Eva
Fäldt, Eric
Walsh, Kieron
Chotteau, Véronique
author_facet Clincke, Marie-Françoise
Mölleryd, Carin
Samani, Puneeth K
Lindskog, Eva
Fäldt, Eric
Walsh, Kieron
Chotteau, Véronique
author_sort Clincke, Marie-Françoise
collection PubMed
description A high cell density perfusion process of monoclonal antibody (MAb) producing Chinese hamster ovary (CHO) cells was developed in disposable WAVE Bioreactor™ using external hollow fiber (HF) filter as cell separation device. Tangential flow filtration (TFF) and alternating tangential flow (ATF) systems were compared and process applications of high cell density perfusion were studied here: MAb production and cryopreservation. Operations by perfusion using microfiltration (MF) or ultrafiltration (UF) with ATF or TFF and by fed-batch were compared. Cell densities higher than 10(8) cells/mL were obtained using UF TFF or UF ATF. The cells produced comparable amounts of MAb in perfusion by ATF or TFF, MF or UF. MAbs were partially retained by the MF using ATF or TFF but more severely using TFF. Consequently, MAbs were lost when cell broth was discarded from the bioreactor in the daily bleeds. The MAb cell-specific productivity was comparable at cell densities up to 1.3 × 10(8) cells/mL in perfusion and was comparable or lower in fed-batch. After 12 days, six times more MAbs were harvested using perfusion by ATF or TFF with MF or UF, compared to fed-batch and 28× more in a 1-month perfusion at 10(8) cells/mL density. Pumping at a recirculation rate up to 2.75 L/min did not damage the cells with the present TFF settings with HF short circuited. Cell cryopreservation at 0.5 × 10(8) and 10(8) cells/mL was performed using cells from a perfusion run at 10(8) cells/mL density. Cell resuscitation was very successful, showing that this system was a reliable process for cell bank manufacturing. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:768–777, 2013
format Online
Article
Text
id pubmed-3752935
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-37529352013-08-30 Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation Clincke, Marie-Françoise Mölleryd, Carin Samani, Puneeth K Lindskog, Eva Fäldt, Eric Walsh, Kieron Chotteau, Véronique Biotechnol Prog Cell Culture and Tissue Engineering A high cell density perfusion process of monoclonal antibody (MAb) producing Chinese hamster ovary (CHO) cells was developed in disposable WAVE Bioreactor™ using external hollow fiber (HF) filter as cell separation device. Tangential flow filtration (TFF) and alternating tangential flow (ATF) systems were compared and process applications of high cell density perfusion were studied here: MAb production and cryopreservation. Operations by perfusion using microfiltration (MF) or ultrafiltration (UF) with ATF or TFF and by fed-batch were compared. Cell densities higher than 10(8) cells/mL were obtained using UF TFF or UF ATF. The cells produced comparable amounts of MAb in perfusion by ATF or TFF, MF or UF. MAbs were partially retained by the MF using ATF or TFF but more severely using TFF. Consequently, MAbs were lost when cell broth was discarded from the bioreactor in the daily bleeds. The MAb cell-specific productivity was comparable at cell densities up to 1.3 × 10(8) cells/mL in perfusion and was comparable or lower in fed-batch. After 12 days, six times more MAbs were harvested using perfusion by ATF or TFF with MF or UF, compared to fed-batch and 28× more in a 1-month perfusion at 10(8) cells/mL density. Pumping at a recirculation rate up to 2.75 L/min did not damage the cells with the present TFF settings with HF short circuited. Cell cryopreservation at 0.5 × 10(8) and 10(8) cells/mL was performed using cells from a perfusion run at 10(8) cells/mL density. Cell resuscitation was very successful, showing that this system was a reliable process for cell bank manufacturing. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:768–777, 2013 Blackwell Publishing Ltd 2013-05 2013-05-21 /pmc/articles/PMC3752935/ /pubmed/23436783 http://dx.doi.org/10.1002/btpr.1703 Text en © 2013 American Institute of Chemical Engineers http://creativecommons.org/licenses/by/2.5/ Re-use of this article is permitted in accordance with the Creative Commons Deed, Attribution 2.5, which does not permit commercial exploitation.
spellingShingle Cell Culture and Tissue Engineering
Clincke, Marie-Françoise
Mölleryd, Carin
Samani, Puneeth K
Lindskog, Eva
Fäldt, Eric
Walsh, Kieron
Chotteau, Véronique
Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title_full Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title_fullStr Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title_full_unstemmed Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title_short Very High Density of Chinese Hamster Ovary Cells in Perfusion by Alternating Tangential Flow or Tangential Flow Filtration in WAVE Bioreactor™—Part II: Applications for Antibody Production and Cryopreservation
title_sort very high density of chinese hamster ovary cells in perfusion by alternating tangential flow or tangential flow filtration in wave bioreactor™—part ii: applications for antibody production and cryopreservation
topic Cell Culture and Tissue Engineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3752935/
https://www.ncbi.nlm.nih.gov/pubmed/23436783
http://dx.doi.org/10.1002/btpr.1703
work_keys_str_mv AT clinckemariefrancoise veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT mollerydcarin veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT samanipuneethk veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT lindskogeva veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT faldteric veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT walshkieron veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation
AT chotteauveronique veryhighdensityofchinesehamsterovarycellsinperfusionbyalternatingtangentialflowortangentialflowfiltrationinwavebioreactorpartiiapplicationsforantibodyproductionandcryopreservation