Cargando…

Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model

Despite progress in the design of advanced surgical techniques, stenosis recurs in a large percentage of vascular anastomosis. In this study, a novel heparin-poloxamer (HP) hydrogel was designed and its effects for improving the quality and safety of vascular anastomosis were studied. HP copolymer w...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Ying-Zheng, Lv, Hai-Feng, Lu, Cui-Tao, Chen, Li-Juan, Lin, Min, Zhang, Ming, Jiang, Xi, Shen, Xiao-Tong, Jin, Rong-Rong, Cai, Jun, Tian, Xin-Qiao, Wong, Ho Lun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3755001/
https://www.ncbi.nlm.nih.gov/pubmed/24015296
http://dx.doi.org/10.1371/journal.pone.0073178
_version_ 1782281947657011200
author Zhao, Ying-Zheng
Lv, Hai-Feng
Lu, Cui-Tao
Chen, Li-Juan
Lin, Min
Zhang, Ming
Jiang, Xi
Shen, Xiao-Tong
Jin, Rong-Rong
Cai, Jun
Tian, Xin-Qiao
Wong, Ho Lun
author_facet Zhao, Ying-Zheng
Lv, Hai-Feng
Lu, Cui-Tao
Chen, Li-Juan
Lin, Min
Zhang, Ming
Jiang, Xi
Shen, Xiao-Tong
Jin, Rong-Rong
Cai, Jun
Tian, Xin-Qiao
Wong, Ho Lun
author_sort Zhao, Ying-Zheng
collection PubMed
description Despite progress in the design of advanced surgical techniques, stenosis recurs in a large percentage of vascular anastomosis. In this study, a novel heparin-poloxamer (HP) hydrogel was designed and its effects for improving the quality and safety of vascular anastomosis were studied. HP copolymer was synthesized and its structure was confirmed by Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectroscopy ((1)H-NMR). Hydrogels containing HP were prepared and their important characteristics related to the application in vascular anastomosis including gelation temperature, rheological behaviour and micromorphology were measured. Vascular anastomosis were performed on the right common carotid arteries of rabbits, and the in vivo efficiency and safety of HP hydrogel to achieve vascular anastomosis was verified and compared with Poloxamer 407 hydrogel and the conventional hand-sewn method using Doppler ultrasound, CT angiograms, scanning electron microscopy (SEM) and histological technique. Our results showed that HP copolymer displayed special gel-sol-gel phase transition behavior with increasing temperature from 5 to 60 °C. HP hydrogel prepared from 18 wt% HP solution had a porous sponge-like structure, with gelation temperature at approximately 38 °C and maximum elastic modulus at 10,000 Pa. In animal studies, imaging and histological examination of rabbit common jugular artery confirmed that HP hydrogel group had similar equivalent patency, flow and burst strength as Poloxamer 407 group. Moreover, HP hydrogel was superior to poloxamer 407 hydrogel and hand-sewn method for restoring the functions and epithelial structure of the broken vessel junctions after operation. By combining the advantages of heparin and poloxamer 407, HP hydrogel holds high promise for improving vascular anastomosis quality and safety.
format Online
Article
Text
id pubmed-3755001
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37550012013-09-06 Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model Zhao, Ying-Zheng Lv, Hai-Feng Lu, Cui-Tao Chen, Li-Juan Lin, Min Zhang, Ming Jiang, Xi Shen, Xiao-Tong Jin, Rong-Rong Cai, Jun Tian, Xin-Qiao Wong, Ho Lun PLoS One Research Article Despite progress in the design of advanced surgical techniques, stenosis recurs in a large percentage of vascular anastomosis. In this study, a novel heparin-poloxamer (HP) hydrogel was designed and its effects for improving the quality and safety of vascular anastomosis were studied. HP copolymer was synthesized and its structure was confirmed by Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectroscopy ((1)H-NMR). Hydrogels containing HP were prepared and their important characteristics related to the application in vascular anastomosis including gelation temperature, rheological behaviour and micromorphology were measured. Vascular anastomosis were performed on the right common carotid arteries of rabbits, and the in vivo efficiency and safety of HP hydrogel to achieve vascular anastomosis was verified and compared with Poloxamer 407 hydrogel and the conventional hand-sewn method using Doppler ultrasound, CT angiograms, scanning electron microscopy (SEM) and histological technique. Our results showed that HP copolymer displayed special gel-sol-gel phase transition behavior with increasing temperature from 5 to 60 °C. HP hydrogel prepared from 18 wt% HP solution had a porous sponge-like structure, with gelation temperature at approximately 38 °C and maximum elastic modulus at 10,000 Pa. In animal studies, imaging and histological examination of rabbit common jugular artery confirmed that HP hydrogel group had similar equivalent patency, flow and burst strength as Poloxamer 407 group. Moreover, HP hydrogel was superior to poloxamer 407 hydrogel and hand-sewn method for restoring the functions and epithelial structure of the broken vessel junctions after operation. By combining the advantages of heparin and poloxamer 407, HP hydrogel holds high promise for improving vascular anastomosis quality and safety. Public Library of Science 2013-08-27 /pmc/articles/PMC3755001/ /pubmed/24015296 http://dx.doi.org/10.1371/journal.pone.0073178 Text en © 2013 Zhao et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Zhao, Ying-Zheng
Lv, Hai-Feng
Lu, Cui-Tao
Chen, Li-Juan
Lin, Min
Zhang, Ming
Jiang, Xi
Shen, Xiao-Tong
Jin, Rong-Rong
Cai, Jun
Tian, Xin-Qiao
Wong, Ho Lun
Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title_full Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title_fullStr Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title_full_unstemmed Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title_short Evaluation of a Novel Thermosensitive Heparin-Poloxamer Hydrogel for Improving Vascular Anastomosis Quality and Safety in a Rabbit Model
title_sort evaluation of a novel thermosensitive heparin-poloxamer hydrogel for improving vascular anastomosis quality and safety in a rabbit model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3755001/
https://www.ncbi.nlm.nih.gov/pubmed/24015296
http://dx.doi.org/10.1371/journal.pone.0073178
work_keys_str_mv AT zhaoyingzheng evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT lvhaifeng evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT lucuitao evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT chenlijuan evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT linmin evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT zhangming evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT jiangxi evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT shenxiaotong evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT jinrongrong evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT caijun evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT tianxinqiao evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel
AT wongholun evaluationofanovelthermosensitiveheparinpoloxamerhydrogelforimprovingvascularanastomosisqualityandsafetyinarabbitmodel