Cargando…
Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratorie...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3756235/ https://www.ncbi.nlm.nih.gov/pubmed/24003421 http://dx.doi.org/10.3343/alm.2013.33.5.319 |
_version_ | 1782282060985008128 |
---|---|
author | Hussain, Husniza Khalid, Norhayati Mustafa Selamat, Rusidah Wan Nazaimoon, Wan Mohamud |
author_facet | Hussain, Husniza Khalid, Norhayati Mustafa Selamat, Rusidah Wan Nazaimoon, Wan Mohamud |
author_sort | Hussain, Husniza |
collection | PubMed |
description | BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TE(a)s) set by two external quality assurance (EQA) providers. RESULTS: UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TE(a)s showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TE(calc))<total allowable error (TE(a)) for the low concentration level; all laboratories showed an acceptable performance for the medium-high level, and two laboratories showed an acceptable performance for the high level. When calculated against the Ensuring the Quality of UI Procedures (EQUIP) TE(a)s, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TE(calc)<TE(a) for the medium-high and high concentrations. CONCLUSIONS: UIMM showed unacceptable performance for the iodine deficiency levels and variable performance at other concentrations according to different TE(a)s. |
format | Online Article Text |
id | pubmed-3756235 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-37562352013-09-04 Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics Hussain, Husniza Khalid, Norhayati Mustafa Selamat, Rusidah Wan Nazaimoon, Wan Mohamud Ann Lab Med Original Article BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TE(a)s) set by two external quality assurance (EQA) providers. RESULTS: UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TE(a)s showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TE(calc))<total allowable error (TE(a)) for the low concentration level; all laboratories showed an acceptable performance for the medium-high level, and two laboratories showed an acceptable performance for the high level. When calculated against the Ensuring the Quality of UI Procedures (EQUIP) TE(a)s, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TE(calc)<TE(a) for the medium-high and high concentrations. CONCLUSIONS: UIMM showed unacceptable performance for the iodine deficiency levels and variable performance at other concentrations according to different TE(a)s. The Korean Society for Laboratory Medicine 2013-09 2013-08-08 /pmc/articles/PMC3756235/ /pubmed/24003421 http://dx.doi.org/10.3343/alm.2013.33.5.319 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hussain, Husniza Khalid, Norhayati Mustafa Selamat, Rusidah Wan Nazaimoon, Wan Mohamud Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title | Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title_full | Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title_fullStr | Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title_full_unstemmed | Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title_short | Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics |
title_sort | evaluation of the performance of a micromethod for measuring urinary iodine by using six sigma quality metrics |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3756235/ https://www.ncbi.nlm.nih.gov/pubmed/24003421 http://dx.doi.org/10.3343/alm.2013.33.5.319 |
work_keys_str_mv | AT hussainhusniza evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics AT khalidnorhayatimustafa evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics AT selamatrusidah evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics AT wannazaimoonwanmohamud evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics |