Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics

BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratorie...

Descripción completa

Detalles Bibliográficos
Autores principales: Hussain, Husniza, Khalid, Norhayati Mustafa, Selamat, Rusidah, Wan Nazaimoon, Wan Mohamud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3756235/
https://www.ncbi.nlm.nih.gov/pubmed/24003421
http://dx.doi.org/10.3343/alm.2013.33.5.319
_version_ 1782282060985008128
author Hussain, Husniza
Khalid, Norhayati Mustafa
Selamat, Rusidah
Wan Nazaimoon, Wan Mohamud
author_facet Hussain, Husniza
Khalid, Norhayati Mustafa
Selamat, Rusidah
Wan Nazaimoon, Wan Mohamud
author_sort Hussain, Husniza
collection PubMed
description BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TE(a)s) set by two external quality assurance (EQA) providers. RESULTS: UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TE(a)s showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TE(calc))<total allowable error (TE(a)) for the low concentration level; all laboratories showed an acceptable performance for the medium-high level, and two laboratories showed an acceptable performance for the high level. When calculated against the Ensuring the Quality of UI Procedures (EQUIP) TE(a)s, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TE(calc)<TE(a) for the medium-high and high concentrations. CONCLUSIONS: UIMM showed unacceptable performance for the iodine deficiency levels and variable performance at other concentrations according to different TE(a)s.
format Online
Article
Text
id pubmed-3756235
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-37562352013-09-04 Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics Hussain, Husniza Khalid, Norhayati Mustafa Selamat, Rusidah Wan Nazaimoon, Wan Mohamud Ann Lab Med Original Article BACKGROUND: The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS: UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TE(a)s) set by two external quality assurance (EQA) providers. RESULTS: UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TE(a)s showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TE(calc))<total allowable error (TE(a)) for the low concentration level; all laboratories showed an acceptable performance for the medium-high level, and two laboratories showed an acceptable performance for the high level. When calculated against the Ensuring the Quality of UI Procedures (EQUIP) TE(a)s, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TE(calc)<TE(a) for the medium-high and high concentrations. CONCLUSIONS: UIMM showed unacceptable performance for the iodine deficiency levels and variable performance at other concentrations according to different TE(a)s. The Korean Society for Laboratory Medicine 2013-09 2013-08-08 /pmc/articles/PMC3756235/ /pubmed/24003421 http://dx.doi.org/10.3343/alm.2013.33.5.319 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hussain, Husniza
Khalid, Norhayati Mustafa
Selamat, Rusidah
Wan Nazaimoon, Wan Mohamud
Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title_full Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title_fullStr Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title_full_unstemmed Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title_short Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics
title_sort evaluation of the performance of a micromethod for measuring urinary iodine by using six sigma quality metrics
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3756235/
https://www.ncbi.nlm.nih.gov/pubmed/24003421
http://dx.doi.org/10.3343/alm.2013.33.5.319
work_keys_str_mv AT hussainhusniza evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics
AT khalidnorhayatimustafa evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics
AT selamatrusidah evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics
AT wannazaimoonwanmohamud evaluationoftheperformanceofamicromethodformeasuringurinaryiodinebyusingsixsigmaqualitymetrics