Cargando…

Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population

PURPOSE: To investigate the bilateral symmetry of the global corneal topography in normal corneas with a wide range of curvature, astigmatism and thickness values DESIGN: Cross-Sectional Study METHODS: Topography images were recorded for the anterior and posterior surfaces of 342 participants using...

Descripción completa

Detalles Bibliográficos
Autores principales: Bao, Fangjun, Chen, Hao, Yu, Ye, Yu, Jiguo, Zhou, Shi, Wang, Jing, Wang, QinMei, Elsheikh, Ahmed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757004/
https://www.ncbi.nlm.nih.gov/pubmed/24009752
http://dx.doi.org/10.1371/journal.pone.0073412
_version_ 1782282153279619072
author Bao, Fangjun
Chen, Hao
Yu, Ye
Yu, Jiguo
Zhou, Shi
Wang, Jing
Wang, QinMei
Elsheikh, Ahmed
author_facet Bao, Fangjun
Chen, Hao
Yu, Ye
Yu, Jiguo
Zhou, Shi
Wang, Jing
Wang, QinMei
Elsheikh, Ahmed
author_sort Bao, Fangjun
collection PubMed
description PURPOSE: To investigate the bilateral symmetry of the global corneal topography in normal corneas with a wide range of curvature, astigmatism and thickness values DESIGN: Cross-Sectional Study METHODS: Topography images were recorded for the anterior and posterior surfaces of 342 participants using a Pentacam. Elevation data were fitted to a general quadratic model that considered both translational and rotational displacements. Comparisons between fellow corneas of estimates of corneal shape parameters (elevation, radius in two main directions, R(x) and R(y), and corresponding shape factors, Q(x) and Q(y)) and corneal position parameters (translational displacements: x(0), y(0) and z(0), and rotational displacements: α, β and γ) were statistically analyzed. RESULTS: The general quadratic model provided average RMS of fit errors with the topography data of 1.7±0.6 µm and 5.7±1.3 µm in anterior and posterior corneal surfaces. The comparisons showed highly significant bilateral correlations with the differences between fellow corneas in R(x), R(y), Q(x) and Q(y) of anterior and posterior surfaces remaining insignificantly different from zero. Bilateral differences in elevation measurements at randomly-selected points in both corneal central and peripheral areas indicated strong mirror symmetry between fellow corneas. The mean geometric center (x(0), y(0), z(0)) of both right and left corneas was located on the temporal side and inferior-temporal side of the apex in anterior and posterior topography map, respectively. Rotational displacement angle α along X axis had similar distributions in bilateral corneas, while rotation angle β along Y axis showed both eyes tilting towards the nasal side. Further, rotation angle γ along Z axis, which is related to corneal astigmatism, showed clear mirror symmetry. CONCLUSIONS: Analysis of corneal topography demonstrated strong and statistically-significant mirror symmetry between bilateral corneas. This characteristic could help in detection of pathological abnormalities, disease diagnosis, measurement validation and surgery planning.
format Online
Article
Text
id pubmed-3757004
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37570042013-09-05 Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population Bao, Fangjun Chen, Hao Yu, Ye Yu, Jiguo Zhou, Shi Wang, Jing Wang, QinMei Elsheikh, Ahmed PLoS One Research Article PURPOSE: To investigate the bilateral symmetry of the global corneal topography in normal corneas with a wide range of curvature, astigmatism and thickness values DESIGN: Cross-Sectional Study METHODS: Topography images were recorded for the anterior and posterior surfaces of 342 participants using a Pentacam. Elevation data were fitted to a general quadratic model that considered both translational and rotational displacements. Comparisons between fellow corneas of estimates of corneal shape parameters (elevation, radius in two main directions, R(x) and R(y), and corresponding shape factors, Q(x) and Q(y)) and corneal position parameters (translational displacements: x(0), y(0) and z(0), and rotational displacements: α, β and γ) were statistically analyzed. RESULTS: The general quadratic model provided average RMS of fit errors with the topography data of 1.7±0.6 µm and 5.7±1.3 µm in anterior and posterior corneal surfaces. The comparisons showed highly significant bilateral correlations with the differences between fellow corneas in R(x), R(y), Q(x) and Q(y) of anterior and posterior surfaces remaining insignificantly different from zero. Bilateral differences in elevation measurements at randomly-selected points in both corneal central and peripheral areas indicated strong mirror symmetry between fellow corneas. The mean geometric center (x(0), y(0), z(0)) of both right and left corneas was located on the temporal side and inferior-temporal side of the apex in anterior and posterior topography map, respectively. Rotational displacement angle α along X axis had similar distributions in bilateral corneas, while rotation angle β along Y axis showed both eyes tilting towards the nasal side. Further, rotation angle γ along Z axis, which is related to corneal astigmatism, showed clear mirror symmetry. CONCLUSIONS: Analysis of corneal topography demonstrated strong and statistically-significant mirror symmetry between bilateral corneas. This characteristic could help in detection of pathological abnormalities, disease diagnosis, measurement validation and surgery planning. Public Library of Science 2013-08-29 /pmc/articles/PMC3757004/ /pubmed/24009752 http://dx.doi.org/10.1371/journal.pone.0073412 Text en © 2013 Bao et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Bao, Fangjun
Chen, Hao
Yu, Ye
Yu, Jiguo
Zhou, Shi
Wang, Jing
Wang, QinMei
Elsheikh, Ahmed
Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title_full Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title_fullStr Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title_full_unstemmed Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title_short Evaluation of the Shape Symmetry of Bilateral Normal Corneas in a Chinese Population
title_sort evaluation of the shape symmetry of bilateral normal corneas in a chinese population
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757004/
https://www.ncbi.nlm.nih.gov/pubmed/24009752
http://dx.doi.org/10.1371/journal.pone.0073412
work_keys_str_mv AT baofangjun evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT chenhao evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT yuye evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT yujiguo evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT zhoushi evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT wangjing evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT wangqinmei evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation
AT elsheikhahmed evaluationoftheshapesymmetryofbilateralnormalcorneasinachinesepopulation