Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension

Pulmonary hypertension (PH) often leads to dilatation of the pulmonary artery (PA), which can be measured on chest computed tomography (CT). While the predictive capability of PA dilatation is useful to distinguish PH (mean PA pressure ≥25 mmHg) from normal (mean PA pressure ≤ 20 mmHg), CT character...

Descripción completa

Detalles Bibliográficos
Autores principales: Lange, Tobias J., Dornia, Christian, Stiefel, Jaroslava, Stroszczynski, Christian, Arzt, Michael, Pfeifer, Michael, Hamer, Okka W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757831/
https://www.ncbi.nlm.nih.gov/pubmed/24015337
http://dx.doi.org/10.4103/2045-8932.113175
_version_ 1782282278685114368
author Lange, Tobias J.
Dornia, Christian
Stiefel, Jaroslava
Stroszczynski, Christian
Arzt, Michael
Pfeifer, Michael
Hamer, Okka W.
author_facet Lange, Tobias J.
Dornia, Christian
Stiefel, Jaroslava
Stroszczynski, Christian
Arzt, Michael
Pfeifer, Michael
Hamer, Okka W.
author_sort Lange, Tobias J.
collection PubMed
description Pulmonary hypertension (PH) often leads to dilatation of the pulmonary artery (PA), which can be measured on chest computed tomography (CT). While the predictive capability of PA dilatation is useful to distinguish PH (mean PA pressure ≥25 mmHg) from normal (mean PA pressure ≤ 20 mmHg), CT characteristics of borderline PH (mean PA pressure 21-24 mmHg) have not been described. We aimed to investigate whether patients with borderline PH already show PA dilatation and to assess the diagnostic accuracy of PA dilatation for borderline PH diagnosis. Between April 2003 and September 2008, consecutive symptomatic patients with a mean PA pressure below 25 mmHg on right heart catheterization who had a chest CT available were retrospectively included. PA diameters from chest CT were correlated with hemodynamic measurements and analyzed with respect to their accuracy of predicting borderline PH. Main PA diameters were significantly larger in 26 patients with borderline PH compared with 52 patients without PH (3.16 ± 0.53 vs. 2.78 ± 0.43 cm, P = 0.001). The main PA diameter on CT correlated with mean PA pressure (r = 0.496, P < 0.001) and pulmonary vascular resistance (r = 0.445, P < 0.001), and predicted borderline PH with sensitivity, specificity, negative and positive predictive values of 77%, 62%, 84%, and 50%, respectively, using a cutoff ≥2.9 cm. This first systematic investigation of CT parameters in symptomatic patients with mean PA pressures less than 25 mmHg could show that, even in patients with borderline PH, significant PA dilatation can be present, which was related to PA pressure and pulmonary vascular resistance. This can be useful for identification of patients with borderline PH for further study and to prompt further diagnostic work-up of possible underlying diseases.
format Online
Article
Text
id pubmed-3757831
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37578312013-09-06 Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension Lange, Tobias J. Dornia, Christian Stiefel, Jaroslava Stroszczynski, Christian Arzt, Michael Pfeifer, Michael Hamer, Okka W. Pulm Circ Research Article Pulmonary hypertension (PH) often leads to dilatation of the pulmonary artery (PA), which can be measured on chest computed tomography (CT). While the predictive capability of PA dilatation is useful to distinguish PH (mean PA pressure ≥25 mmHg) from normal (mean PA pressure ≤ 20 mmHg), CT characteristics of borderline PH (mean PA pressure 21-24 mmHg) have not been described. We aimed to investigate whether patients with borderline PH already show PA dilatation and to assess the diagnostic accuracy of PA dilatation for borderline PH diagnosis. Between April 2003 and September 2008, consecutive symptomatic patients with a mean PA pressure below 25 mmHg on right heart catheterization who had a chest CT available were retrospectively included. PA diameters from chest CT were correlated with hemodynamic measurements and analyzed with respect to their accuracy of predicting borderline PH. Main PA diameters were significantly larger in 26 patients with borderline PH compared with 52 patients without PH (3.16 ± 0.53 vs. 2.78 ± 0.43 cm, P = 0.001). The main PA diameter on CT correlated with mean PA pressure (r = 0.496, P < 0.001) and pulmonary vascular resistance (r = 0.445, P < 0.001), and predicted borderline PH with sensitivity, specificity, negative and positive predictive values of 77%, 62%, 84%, and 50%, respectively, using a cutoff ≥2.9 cm. This first systematic investigation of CT parameters in symptomatic patients with mean PA pressures less than 25 mmHg could show that, even in patients with borderline PH, significant PA dilatation can be present, which was related to PA pressure and pulmonary vascular resistance. This can be useful for identification of patients with borderline PH for further study and to prompt further diagnostic work-up of possible underlying diseases. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3757831/ /pubmed/24015337 http://dx.doi.org/10.4103/2045-8932.113175 Text en Copyright: © Pulmonary Circulation http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lange, Tobias J.
Dornia, Christian
Stiefel, Jaroslava
Stroszczynski, Christian
Arzt, Michael
Pfeifer, Michael
Hamer, Okka W.
Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title_full Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title_fullStr Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title_full_unstemmed Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title_short Increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
title_sort increased pulmonary artery diameter on chest computed tomography can predict borderline pulmonary hypertension
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757831/
https://www.ncbi.nlm.nih.gov/pubmed/24015337
http://dx.doi.org/10.4103/2045-8932.113175
work_keys_str_mv AT langetobiasj increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT dorniachristian increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT stiefeljaroslava increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT stroszczynskichristian increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT arztmichael increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT pfeifermichael increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension
AT hamerokkaw increasedpulmonaryarterydiameteronchestcomputedtomographycanpredictborderlinepulmonaryhypertension