Cargando…
Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation
The simple, selective, precise and accurate reverse-phase high-performance liquid chromatography method was developed and validated for analysis of tadalafil in bulk and tablet dosage form. The column was Inertsil C18 (150×4.6 mm; 5 μm) in isocratic mode. The mobile phase used was phosphate buffer (...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757865/ https://www.ncbi.nlm.nih.gov/pubmed/24019575 |
_version_ | 1782282287347400704 |
---|---|
author | Sonawane, P. H. Panzade, P. S. Kale, M. A. |
author_facet | Sonawane, P. H. Panzade, P. S. Kale, M. A. |
author_sort | Sonawane, P. H. |
collection | PubMed |
description | The simple, selective, precise and accurate reverse-phase high-performance liquid chromatography method was developed and validated for analysis of tadalafil in bulk and tablet dosage form. The column was Inertsil C18 (150×4.6 mm; 5 μm) in isocratic mode. The mobile phase used was phosphate buffer (10 mM, pH 3.2) and acetonitrile (50:50% v/v) at the flow rate of 1.0 ml/min with ultraviolet detection at 295 nm at ambient temperature. The retention time for tadalafil was found to be 4.01 min. Linearity was observed in the concentration range from 60 to 140 μg/ml for tadalafil with a correlation coefficient of (r(2)) 0.9998. The method was validated according to International Conference on Harmonisation guidelines in terms of linearity, accuracy, precision and specificity. Hence, the proposed method can be utilized for routine quality control of tadalafil in bulk and tablet dosage form. |
format | Online Article Text |
id | pubmed-3757865 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-37578652013-09-09 Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation Sonawane, P. H. Panzade, P. S. Kale, M. A. Indian J Pharm Sci Short Communications The simple, selective, precise and accurate reverse-phase high-performance liquid chromatography method was developed and validated for analysis of tadalafil in bulk and tablet dosage form. The column was Inertsil C18 (150×4.6 mm; 5 μm) in isocratic mode. The mobile phase used was phosphate buffer (10 mM, pH 3.2) and acetonitrile (50:50% v/v) at the flow rate of 1.0 ml/min with ultraviolet detection at 295 nm at ambient temperature. The retention time for tadalafil was found to be 4.01 min. Linearity was observed in the concentration range from 60 to 140 μg/ml for tadalafil with a correlation coefficient of (r(2)) 0.9998. The method was validated according to International Conference on Harmonisation guidelines in terms of linearity, accuracy, precision and specificity. Hence, the proposed method can be utilized for routine quality control of tadalafil in bulk and tablet dosage form. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3757865/ /pubmed/24019575 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communications Sonawane, P. H. Panzade, P. S. Kale, M. A. Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title | Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title_full | Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title_fullStr | Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title_full_unstemmed | Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title_short | Rapid Estimation of Tadalafil by Reverse-phase High-performance Liquid Chromatography Method in Bulk and Tablet Formulation |
title_sort | rapid estimation of tadalafil by reverse-phase high-performance liquid chromatography method in bulk and tablet formulation |
topic | Short Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757865/ https://www.ncbi.nlm.nih.gov/pubmed/24019575 |
work_keys_str_mv | AT sonawaneph rapidestimationoftadalafilbyreversephasehighperformanceliquidchromatographymethodinbulkandtabletformulation AT panzadeps rapidestimationoftadalafilbyreversephasehighperformanceliquidchromatographymethodinbulkandtabletformulation AT kalema rapidestimationoftadalafilbyreversephasehighperformanceliquidchromatographymethodinbulkandtabletformulation |