Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form

A simple, accurate, precise and sensitive reverse-phase high-performance liquid chromatography method for the determination of citicoline sodium has been developed and validated. Drug was resolved on a C18 column (Phenomenex Luna, 250×4.6 mm, 10μ), utilizing mobile phase of potassium dihydrogen phos...

Descripción completa

Detalles Bibliográficos
Autores principales: MARADIYA, H. K., PANSARA, VASUNDHARA H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757867/
https://www.ncbi.nlm.nih.gov/pubmed/24019577
_version_ 1782282287794094080
author MARADIYA, H. K.
PANSARA, VASUNDHARA H.
author_facet MARADIYA, H. K.
PANSARA, VASUNDHARA H.
author_sort MARADIYA, H. K.
collection PubMed
description A simple, accurate, precise and sensitive reverse-phase high-performance liquid chromatography method for the determination of citicoline sodium has been developed and validated. Drug was resolved on a C18 column (Phenomenex Luna, 250×4.6 mm, 10μ), utilizing mobile phase of potassium dihydrogen phosphate buffer and acetonitrile in a ratio of 30:70. Mobile phase was delivered at the flow rate of 1.0 ml/min and detection was carried out at 272 nm. Separation was completed within 2.22 min. Calibration curve was linear with good correlation coefficient (R(2)=0.999) over a concentration range 10-60 μg/ml. Recovery was between 98.84 and 101.76%. Method was found to be reproducible with relative standard deviation for intra and interday precision of <2.0% over the said concentration range. The method was successfully applied to the determination of the citicoline sodium, it can be very useful and an alternate to performing the stability studies.
format Online
Article
Text
id pubmed-3757867
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-37578672013-09-09 Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form MARADIYA, H. K. PANSARA, VASUNDHARA H. Indian J Pharm Sci Short Communications A simple, accurate, precise and sensitive reverse-phase high-performance liquid chromatography method for the determination of citicoline sodium has been developed and validated. Drug was resolved on a C18 column (Phenomenex Luna, 250×4.6 mm, 10μ), utilizing mobile phase of potassium dihydrogen phosphate buffer and acetonitrile in a ratio of 30:70. Mobile phase was delivered at the flow rate of 1.0 ml/min and detection was carried out at 272 nm. Separation was completed within 2.22 min. Calibration curve was linear with good correlation coefficient (R(2)=0.999) over a concentration range 10-60 μg/ml. Recovery was between 98.84 and 101.76%. Method was found to be reproducible with relative standard deviation for intra and interday precision of <2.0% over the said concentration range. The method was successfully applied to the determination of the citicoline sodium, it can be very useful and an alternate to performing the stability studies. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3757867/ /pubmed/24019577 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communications
MARADIYA, H. K.
PANSARA, VASUNDHARA H.
Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title_full Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title_fullStr Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title_full_unstemmed Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title_short Development and Validation of Reverse-phase High-performance Liquid Chromatography Method for Estimation of Citicoline Sodium in Bulk and Dosage Form
title_sort development and validation of reverse-phase high-performance liquid chromatography method for estimation of citicoline sodium in bulk and dosage form
topic Short Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757867/
https://www.ncbi.nlm.nih.gov/pubmed/24019577
work_keys_str_mv AT maradiyahk developmentandvalidationofreversephasehighperformanceliquidchromatographymethodforestimationofciticolinesodiuminbulkanddosageform
AT pansaravasundharah developmentandvalidationofreversephasehighperformanceliquidchromatographymethodforestimationofciticolinesodiuminbulkanddosageform