Cargando…
Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair
Patient: Male, 74 Final Diagnosis: Abdominal aortic aneurysm (AAA) Symptoms: Palpable abdominal mass Medication: — Clinical Procedure: Abdominal aortic aneurysm repair Specialty: Surgery OBJECTIVE: Rare disease BACKGROUND: Coronary artery disease is common in elderly patients with abdominal aortic a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757910/ https://www.ncbi.nlm.nih.gov/pubmed/23997852 http://dx.doi.org/10.12659/AJCR.889317 |
_version_ | 1782282297005834240 |
---|---|
author | Gürer, Onur Haberal, Ismail Ozsoy, Deniz |
author_facet | Gürer, Onur Haberal, Ismail Ozsoy, Deniz |
author_sort | Gürer, Onur |
collection | PubMed |
description | Patient: Male, 74 Final Diagnosis: Abdominal aortic aneurysm (AAA) Symptoms: Palpable abdominal mass Medication: — Clinical Procedure: Abdominal aortic aneurysm repair Specialty: Surgery OBJECTIVE: Rare disease BACKGROUND: Coronary artery disease is common in elderly patients with abdominal aortic aneurysms. Here we report a case of the combination of surgical repair for abdominal aortic aneurysm and off-pump and minimally invasive coronary artery bypass surgery. CASE REPORT: A 74-year-old man who presented at our clinic with chest pain was diagnosed with an abdominal aortic aneurysm. His medical history included right coronary artery stenting. Physical examination revealed a pulsatile abdominal mass on the left side and palpable peripheral pulses. Computed tomography scans showed an infrarenal abdominal aneurysm with a 61-mm enlargement. Coronary angiography revealed 80% stenosis in the stent within the right coronary artery and 20% stenosis in the left main coronary artery. The patient underwent elective coronary artery bypass grafting and abdominal aortic aneurysm repair. Abdominal aortic aneurysm repair and transdiaphragmatic off-pump and minimal invasive coronary artery bypass grafting with right gastroepiploic artery were performed simultaneously in a single surgery. CONCLUSIONS: We report this case to emphasize the safety and effectiveness of transdiaphragmatic off-pump and minimally invasive coronary artery bypass surgery with abdominal aortic aneurysm repair. This combined approach shortens hospital stay and decreases cost. |
format | Online Article Text |
id | pubmed-3757910 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-37579102013-08-30 Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair Gürer, Onur Haberal, Ismail Ozsoy, Deniz Am J Case Rep Articles Patient: Male, 74 Final Diagnosis: Abdominal aortic aneurysm (AAA) Symptoms: Palpable abdominal mass Medication: — Clinical Procedure: Abdominal aortic aneurysm repair Specialty: Surgery OBJECTIVE: Rare disease BACKGROUND: Coronary artery disease is common in elderly patients with abdominal aortic aneurysms. Here we report a case of the combination of surgical repair for abdominal aortic aneurysm and off-pump and minimally invasive coronary artery bypass surgery. CASE REPORT: A 74-year-old man who presented at our clinic with chest pain was diagnosed with an abdominal aortic aneurysm. His medical history included right coronary artery stenting. Physical examination revealed a pulsatile abdominal mass on the left side and palpable peripheral pulses. Computed tomography scans showed an infrarenal abdominal aneurysm with a 61-mm enlargement. Coronary angiography revealed 80% stenosis in the stent within the right coronary artery and 20% stenosis in the left main coronary artery. The patient underwent elective coronary artery bypass grafting and abdominal aortic aneurysm repair. Abdominal aortic aneurysm repair and transdiaphragmatic off-pump and minimal invasive coronary artery bypass grafting with right gastroepiploic artery were performed simultaneously in a single surgery. CONCLUSIONS: We report this case to emphasize the safety and effectiveness of transdiaphragmatic off-pump and minimally invasive coronary artery bypass surgery with abdominal aortic aneurysm repair. This combined approach shortens hospital stay and decreases cost. International Scientific Literature, Inc. 2013-08-28 /pmc/articles/PMC3757910/ /pubmed/23997852 http://dx.doi.org/10.12659/AJCR.889317 Text en © Am J Case Rep, 2013 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License |
spellingShingle | Articles Gürer, Onur Haberal, Ismail Ozsoy, Deniz Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title | Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title_full | Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title_fullStr | Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title_full_unstemmed | Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title_short | Combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
title_sort | combined transdiaphragmatic off-pump and minimally invasive coronary artery bypass with right gastroepiploic artery and abdominal aortic aneurysm repair |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757910/ https://www.ncbi.nlm.nih.gov/pubmed/23997852 http://dx.doi.org/10.12659/AJCR.889317 |
work_keys_str_mv | AT gureronur combinedtransdiaphragmaticoffpumpandminimallyinvasivecoronaryarterybypasswithrightgastroepiploicarteryandabdominalaorticaneurysmrepair AT haberalismail combinedtransdiaphragmaticoffpumpandminimallyinvasivecoronaryarterybypasswithrightgastroepiploicarteryandabdominalaorticaneurysmrepair AT ozsoydeniz combinedtransdiaphragmaticoffpumpandminimallyinvasivecoronaryarterybypasswithrightgastroepiploicarteryandabdominalaorticaneurysmrepair |