Cargando…
Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects
BACKGROUND: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is a novel approach for treating peritoneal carcinomatosis. First encouraging results have been obtained in human patients. However, delivering chemotherapy as an aerosol might result in an increased risk of exposure to health care...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3764316/ https://www.ncbi.nlm.nih.gov/pubmed/23765417 http://dx.doi.org/10.1245/s10434-013-3039-x |
_version_ | 1782283130376290304 |
---|---|
author | Solaß, Wiebke Giger-Pabst, Urs Zieren, Jürgen Reymond, Marc A. |
author_facet | Solaß, Wiebke Giger-Pabst, Urs Zieren, Jürgen Reymond, Marc A. |
author_sort | Solaß, Wiebke |
collection | PubMed |
description | BACKGROUND: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is a novel approach for treating peritoneal carcinomatosis. First encouraging results have been obtained in human patients. However, delivering chemotherapy as an aerosol might result in an increased risk of exposure to health care workers, as compared with other administration routes. METHODS: PIPAC was applied in two human patients using chemotherapeutic drugs (doxorubicin and cisplatin), and air contamination levels were measured under real clinical conditions. Air was collected on a cellulose nitrate filter with a flow of 22.5 m(3)/h. To exclude any risk for health care workers, both procedures were remote controlled. Toxicological research of cisplatin was performed according to NIOSH 7300 protocol. Sampling and analysis were performed by an independent certification organization. RESULTS: The following safety measures were implemented: closed abdomen, laminar airflow, controlled aerosol waste, and protection curtain. No cisplatin was detected in the air (detection limit < 0.000009 mg/m(3)) at the working positions of the surgeon and the anesthesiologist under real PIPAC conditions. CONCLUSIONS: For the drugs tested, PIPAC is in compliance with European Community working safety law and regulations. Workplace contamination remains below the tolerance margin. The safety measures and conditions as defined above are sufficient. Further protecting devices, such as particulate (air purifying) masks, are not necessary. PIPAC can be used safely in the clinical setting if the conditions specified above are met. However, a toxicological workplace analysis must be performed to confirm that the procedure as implemented complies with local regulations. |
format | Online Article Text |
id | pubmed-3764316 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-37643162013-09-09 Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects Solaß, Wiebke Giger-Pabst, Urs Zieren, Jürgen Reymond, Marc A. Ann Surg Oncol Gastrointestinal Oncology BACKGROUND: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is a novel approach for treating peritoneal carcinomatosis. First encouraging results have been obtained in human patients. However, delivering chemotherapy as an aerosol might result in an increased risk of exposure to health care workers, as compared with other administration routes. METHODS: PIPAC was applied in two human patients using chemotherapeutic drugs (doxorubicin and cisplatin), and air contamination levels were measured under real clinical conditions. Air was collected on a cellulose nitrate filter with a flow of 22.5 m(3)/h. To exclude any risk for health care workers, both procedures were remote controlled. Toxicological research of cisplatin was performed according to NIOSH 7300 protocol. Sampling and analysis were performed by an independent certification organization. RESULTS: The following safety measures were implemented: closed abdomen, laminar airflow, controlled aerosol waste, and protection curtain. No cisplatin was detected in the air (detection limit < 0.000009 mg/m(3)) at the working positions of the surgeon and the anesthesiologist under real PIPAC conditions. CONCLUSIONS: For the drugs tested, PIPAC is in compliance with European Community working safety law and regulations. Workplace contamination remains below the tolerance margin. The safety measures and conditions as defined above are sufficient. Further protecting devices, such as particulate (air purifying) masks, are not necessary. PIPAC can be used safely in the clinical setting if the conditions specified above are met. However, a toxicological workplace analysis must be performed to confirm that the procedure as implemented complies with local regulations. Springer US 2013-06-14 2013 /pmc/articles/PMC3764316/ /pubmed/23765417 http://dx.doi.org/10.1245/s10434-013-3039-x Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Gastrointestinal Oncology Solaß, Wiebke Giger-Pabst, Urs Zieren, Jürgen Reymond, Marc A. Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title | Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title_full | Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title_fullStr | Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title_full_unstemmed | Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title_short | Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC): Occupational Health and Safety Aspects |
title_sort | pressurized intraperitoneal aerosol chemotherapy (pipac): occupational health and safety aspects |
topic | Gastrointestinal Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3764316/ https://www.ncbi.nlm.nih.gov/pubmed/23765417 http://dx.doi.org/10.1245/s10434-013-3039-x |
work_keys_str_mv | AT solaßwiebke pressurizedintraperitonealaerosolchemotherapypipacoccupationalhealthandsafetyaspects AT gigerpabsturs pressurizedintraperitonealaerosolchemotherapypipacoccupationalhealthandsafetyaspects AT zierenjurgen pressurizedintraperitonealaerosolchemotherapypipacoccupationalhealthandsafetyaspects AT reymondmarca pressurizedintraperitonealaerosolchemotherapypipacoccupationalhealthandsafetyaspects |