Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice

BACKGROUND: Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatia...

Descripción completa

Detalles Bibliográficos
Autores principales: Haggerty, Christopher M, Kramer, Sage P, Binkley, Cassi M, Powell, David K, Mattingly, Andrea C, Charnigo, Richard, Epstein, Frederick H, Fornwalt, Brandon K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3765995/
https://www.ncbi.nlm.nih.gov/pubmed/23981339
http://dx.doi.org/10.1186/1532-429X-15-71
_version_ 1782283439380103168
author Haggerty, Christopher M
Kramer, Sage P
Binkley, Cassi M
Powell, David K
Mattingly, Andrea C
Charnigo, Richard
Epstein, Frederick H
Fornwalt, Brandon K
author_facet Haggerty, Christopher M
Kramer, Sage P
Binkley, Cassi M
Powell, David K
Mattingly, Andrea C
Charnigo, Richard
Epstein, Frederick H
Fornwalt, Brandon K
author_sort Haggerty, Christopher M
collection PubMed
description BACKGROUND: Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice. METHODS: Five normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15–20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer’s analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility. RESULTS: LV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent reproducibility with CoVs of 1% and 3%, respectively. Finally, peak measures (e.g., strains) were generally more reproducible than the corresponding rates of change (e.g., strain rate). CONCLUSIONS: Cine DENSE CMR is a highly reproducible technique for quantification of advanced measures of left ventricular cardiac function in mice including strains, torsion and measures of synchrony. However, myocardial twist angles are not reproducible and future studies should instead report torsion.
format Online
Article
Text
id pubmed-3765995
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37659952013-09-12 Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice Haggerty, Christopher M Kramer, Sage P Binkley, Cassi M Powell, David K Mattingly, Andrea C Charnigo, Richard Epstein, Frederick H Fornwalt, Brandon K J Cardiovasc Magn Reson Research BACKGROUND: Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice. METHODS: Five normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15–20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer’s analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility. RESULTS: LV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent reproducibility with CoVs of 1% and 3%, respectively. Finally, peak measures (e.g., strains) were generally more reproducible than the corresponding rates of change (e.g., strain rate). CONCLUSIONS: Cine DENSE CMR is a highly reproducible technique for quantification of advanced measures of left ventricular cardiac function in mice including strains, torsion and measures of synchrony. However, myocardial twist angles are not reproducible and future studies should instead report torsion. BioMed Central 2013-08-27 /pmc/articles/PMC3765995/ /pubmed/23981339 http://dx.doi.org/10.1186/1532-429X-15-71 Text en Copyright © 2013 Haggerty et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Haggerty, Christopher M
Kramer, Sage P
Binkley, Cassi M
Powell, David K
Mattingly, Andrea C
Charnigo, Richard
Epstein, Frederick H
Fornwalt, Brandon K
Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title_full Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title_fullStr Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title_full_unstemmed Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title_short Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
title_sort reproducibility of cine displacement encoding with stimulated echoes (dense) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3765995/
https://www.ncbi.nlm.nih.gov/pubmed/23981339
http://dx.doi.org/10.1186/1532-429X-15-71
work_keys_str_mv AT haggertychristopherm reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT kramersagep reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT binkleycassim reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT powelldavidk reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT mattinglyandreac reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT charnigorichard reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT epsteinfrederickh reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice
AT fornwaltbrandonk reproducibilityofcinedisplacementencodingwithstimulatedechoesdensecardiovascularmagneticresonanceformeasuringleftventricularstrainstorsionandsynchronyinmice