Acute thrombosis of bioprosthetic mitral valve
We report a case of acute thrombosis of bioprosthetic mitral valve in a 59 year–old Korean female, who underwent a mitral valve replacement with a 25 mm Carpentier - Edwards PERIMOUNT Plus bioprosthesis (Edwards Lifesciences, Inc.; Irvine, CA, USA) and a mini-Maze procedure for correction of mitral...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3766078/ https://www.ncbi.nlm.nih.gov/pubmed/23981275 http://dx.doi.org/10.1186/1749-8090-8-185 |
_version_ | 1782283459751837696 |
---|---|
author | Kwon, Jin-Tae Jung, Tae-Eun Lee, Dong-Hyup |
author_facet | Kwon, Jin-Tae Jung, Tae-Eun Lee, Dong-Hyup |
author_sort | Kwon, Jin-Tae |
collection | PubMed |
description | We report a case of acute thrombosis of bioprosthetic mitral valve in a 59 year–old Korean female, who underwent a mitral valve replacement with a 25 mm Carpentier - Edwards PERIMOUNT Plus bioprosthesis (Edwards Lifesciences, Inc.; Irvine, CA, USA) and a mini-Maze procedure for correction of mitral stenosis (MS) and atrial fibrillation (AF). On the 10th postoperative day, the patient began to complain of increasing dyspnea and general malaise. Her symptoms worsened and developed into pulmonary edema. Echocardiography revealed a mean diastolic pressure gradient (MDPG) of 10 mmHg across the mitral valve and pressure-half time (PHT) of 166 msec. Due to progressive decompensated heart failure, the patient underwent a repeat sternotomy to replace the bioprosthetic mitral valve. Intraoperatively, we found a thrombosis around the bioprosthetic mitral valve. We excised the bioprosthetic mitral valve and replaced it with a 27 mm ATS mechanical valve (ATS medical, Inc.; Minneapolis, MN, USA). We experienced a rare case that required an early reoperation for a thrombosis of the bioprosthetic valve. |
format | Online Article Text |
id | pubmed-3766078 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-37660782013-09-08 Acute thrombosis of bioprosthetic mitral valve Kwon, Jin-Tae Jung, Tae-Eun Lee, Dong-Hyup J Cardiothorac Surg Case Report We report a case of acute thrombosis of bioprosthetic mitral valve in a 59 year–old Korean female, who underwent a mitral valve replacement with a 25 mm Carpentier - Edwards PERIMOUNT Plus bioprosthesis (Edwards Lifesciences, Inc.; Irvine, CA, USA) and a mini-Maze procedure for correction of mitral stenosis (MS) and atrial fibrillation (AF). On the 10th postoperative day, the patient began to complain of increasing dyspnea and general malaise. Her symptoms worsened and developed into pulmonary edema. Echocardiography revealed a mean diastolic pressure gradient (MDPG) of 10 mmHg across the mitral valve and pressure-half time (PHT) of 166 msec. Due to progressive decompensated heart failure, the patient underwent a repeat sternotomy to replace the bioprosthetic mitral valve. Intraoperatively, we found a thrombosis around the bioprosthetic mitral valve. We excised the bioprosthetic mitral valve and replaced it with a 27 mm ATS mechanical valve (ATS medical, Inc.; Minneapolis, MN, USA). We experienced a rare case that required an early reoperation for a thrombosis of the bioprosthetic valve. BioMed Central 2013-08-27 /pmc/articles/PMC3766078/ /pubmed/23981275 http://dx.doi.org/10.1186/1749-8090-8-185 Text en Copyright © 2013 Kwon et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kwon, Jin-Tae Jung, Tae-Eun Lee, Dong-Hyup Acute thrombosis of bioprosthetic mitral valve |
title | Acute thrombosis of bioprosthetic mitral valve |
title_full | Acute thrombosis of bioprosthetic mitral valve |
title_fullStr | Acute thrombosis of bioprosthetic mitral valve |
title_full_unstemmed | Acute thrombosis of bioprosthetic mitral valve |
title_short | Acute thrombosis of bioprosthetic mitral valve |
title_sort | acute thrombosis of bioprosthetic mitral valve |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3766078/ https://www.ncbi.nlm.nih.gov/pubmed/23981275 http://dx.doi.org/10.1186/1749-8090-8-185 |
work_keys_str_mv | AT kwonjintae acutethrombosisofbioprostheticmitralvalve AT jungtaeeun acutethrombosisofbioprostheticmitralvalve AT leedonghyup acutethrombosisofbioprostheticmitralvalve |