Cargando…

Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions

BACKGROUND: Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface el...

Descripción completa

Detalles Bibliográficos
Autores principales: Chauhan, Munish, Jeong, Woo Chul, Kim, Hyung Joong, Kwon, Oh In, Woo, Eung Je
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3766253/
https://www.ncbi.nlm.nih.gov/pubmed/23981409
http://dx.doi.org/10.1186/1475-925X-12-82
_version_ 1782283499528519680
author Chauhan, Munish
Jeong, Woo Chul
Kim, Hyung Joong
Kwon, Oh In
Woo, Eung Je
author_facet Chauhan, Munish
Jeong, Woo Chul
Kim, Hyung Joong
Kwon, Oh In
Woo, Eung Je
author_sort Chauhan, Munish
collection PubMed
description BACKGROUND: Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface electrodes induces a magnetic flux density distribution inside the imaging object, which results in additional magnetic flux density. To measure the magnetic flux density signal in MREIT, the phase difference approach in an interleaved encoding scheme cancels out the systematic artifacts accumulated in phase signals and also reduces the random noise effect by doubling the measured magnetic flux density signal. For practical applications of in vivo MREIT, it is essential to reduce the scan duration maintaining spatial-resolution and sufficient contrast. In this paper, we optimize the magnetic flux density by using a fast gradient multi-echo MR pulse sequence. To recover the one component of magnetic flux density B(z), we use a coupled partial Fourier acquisitions in the interleaved sense. METHODS: To prove the proposed algorithm, we performed numerical simulations using a two-dimensional finite-element model. For a real experiment, we designed a phantom filled with a calibrated saline solution and located a rubber balloon inside the phantom. The rubber balloon was inflated by injecting the same saline solution during the MREIT imaging. We used the multi-echo fast low angle shot (FLASH) MR pulse sequence for MRI scan, which allows the reduction of measuring time without a substantial loss in image quality. RESULTS: Under the assumption of a priori phase artifact map from a reference scan, we rigorously investigated the convergence ratio of the proposed method, which was closely related with the number of measured phase encode set and the frequency range of the background field inhomogeneity. In the phantom experiment with a partial Fourier acquisition, the total scan time was less than 6 seconds to measure the magnetic flux density B(z) data with 128×128 spacial matrix size, where it required 10.24 seconds to fill the complete k-space region. CONCLUSION: Numerical simulation and experimental results demonstrated that the proposed method reduces the scanning time and provides the recovered B(z) data comparable to what we obtained by measuring complete k-space data.
format Online
Article
Text
id pubmed-3766253
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-37662532013-09-10 Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions Chauhan, Munish Jeong, Woo Chul Kim, Hyung Joong Kwon, Oh In Woo, Eung Je Biomed Eng Online Research BACKGROUND: Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface electrodes induces a magnetic flux density distribution inside the imaging object, which results in additional magnetic flux density. To measure the magnetic flux density signal in MREIT, the phase difference approach in an interleaved encoding scheme cancels out the systematic artifacts accumulated in phase signals and also reduces the random noise effect by doubling the measured magnetic flux density signal. For practical applications of in vivo MREIT, it is essential to reduce the scan duration maintaining spatial-resolution and sufficient contrast. In this paper, we optimize the magnetic flux density by using a fast gradient multi-echo MR pulse sequence. To recover the one component of magnetic flux density B(z), we use a coupled partial Fourier acquisitions in the interleaved sense. METHODS: To prove the proposed algorithm, we performed numerical simulations using a two-dimensional finite-element model. For a real experiment, we designed a phantom filled with a calibrated saline solution and located a rubber balloon inside the phantom. The rubber balloon was inflated by injecting the same saline solution during the MREIT imaging. We used the multi-echo fast low angle shot (FLASH) MR pulse sequence for MRI scan, which allows the reduction of measuring time without a substantial loss in image quality. RESULTS: Under the assumption of a priori phase artifact map from a reference scan, we rigorously investigated the convergence ratio of the proposed method, which was closely related with the number of measured phase encode set and the frequency range of the background field inhomogeneity. In the phantom experiment with a partial Fourier acquisition, the total scan time was less than 6 seconds to measure the magnetic flux density B(z) data with 128×128 spacial matrix size, where it required 10.24 seconds to fill the complete k-space region. CONCLUSION: Numerical simulation and experimental results demonstrated that the proposed method reduces the scanning time and provides the recovered B(z) data comparable to what we obtained by measuring complete k-space data. BioMed Central 2013-08-27 /pmc/articles/PMC3766253/ /pubmed/23981409 http://dx.doi.org/10.1186/1475-925X-12-82 Text en Copyright © 2013 Chauhan et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Chauhan, Munish
Jeong, Woo Chul
Kim, Hyung Joong
Kwon, Oh In
Woo, Eung Je
Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title_full Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title_fullStr Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title_full_unstemmed Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title_short Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions
title_sort optimization of magnetic flux density for fast mreit conductivity imaging using multi-echo interleaved partial fourier acquisitions
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3766253/
https://www.ncbi.nlm.nih.gov/pubmed/23981409
http://dx.doi.org/10.1186/1475-925X-12-82
work_keys_str_mv AT chauhanmunish optimizationofmagneticfluxdensityforfastmreitconductivityimagingusingmultiechointerleavedpartialfourieracquisitions
AT jeongwoochul optimizationofmagneticfluxdensityforfastmreitconductivityimagingusingmultiechointerleavedpartialfourieracquisitions
AT kimhyungjoong optimizationofmagneticfluxdensityforfastmreitconductivityimagingusingmultiechointerleavedpartialfourieracquisitions
AT kwonohin optimizationofmagneticfluxdensityforfastmreitconductivityimagingusingmultiechointerleavedpartialfourieracquisitions
AT wooeungje optimizationofmagneticfluxdensityforfastmreitconductivityimagingusingmultiechointerleavedpartialfourieracquisitions