BACKGROUND AND OBJECTIVES: Many disposable platforms have been applied in laparoendoscopic single-site surgery (LESS). Besides technical issues, cost is one of the limiting factors for its widespread acceptance. The current study describes the first completely reusable LESS-platform. METHODS: We per...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwentner, C., Todenhöfer, T., Seibold, J., Alloussi, S., Aufderklamm, S., Mischinger, J., Stenzl, A., Gakis, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3771796/
https://www.ncbi.nlm.nih.gov/pubmed/23925023
http://dx.doi.org/10.4293/108680813X13654754534477
_version_ 1782284227797057536
author Schwentner, C.
Todenhöfer, T.
Seibold, J.
Alloussi, S.
Aufderklamm, S.
Mischinger, J.
Stenzl, A.
Gakis, G.
author_facet Schwentner, C.
Todenhöfer, T.
Seibold, J.
Alloussi, S.
Aufderklamm, S.
Mischinger, J.
Stenzl, A.
Gakis, G.
author_sort Schwentner, C.
collection PubMed
description BACKGROUND AND OBJECTIVES: Many disposable platforms have been applied in laparoendoscopic single-site surgery (LESS). Besides technical issues, cost is one of the limiting factors for its widespread acceptance. The current study describes the first completely reusable LESS-platform. METHODS: We performed LESS-procedures in 52 patients including nephrectomy (18), adrenalectomy (2), partial nephrectomy (3), pyeloplasty (4), renal cyst ablation (4), pelvic lymphadenectomy (15), and lymphocele ablation (6). All procedures were conducted using a novel reusable single-port device (X-Cone, Karl-Storz) with a simplified set of instruments. We obtained perioperative and demographic data, including a visual analogue pain scale (VAS), and a complication reporting system based on Clavien grading. RESULTS: Mean age was 50.04 y. Conversion to standard laparoscopy was necessary in 3 cases and addition of a needlescopic instrument in 6 cases. There was no open conversion. Intra- and postoperative complications occurred in 3 (Clavien II in 2 and III in 1) cases. Mean operative time was 110, 90, and 89 min, and hospital stay was 4.9, 3.1, and 3.6 d for nephrectomy, pelvic lymphadenectomy, and pyeloplasty, respectively. Mean VAS was 2.13, 1.07, and 1.5 while blood loss was 81.3 mL, 25.67 mL, and 17.5 mL, respectively. Mean lymph node yield was 15 (range, 8 to 21). CONCLUSIONS: A completely reusable LESS-platform is applicable to various uses in urology, yielding favorable functional and cosmetic results. Reusable materials are useful to reduce the cost of LESS, further increasing its acceptance. LESS with a completely reusable platform is more cost effective than standard laparoscopy.
format Online
Article
Text
id pubmed-3771796
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-37717962013-09-16 Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform Schwentner, C. Todenhöfer, T. Seibold, J. Alloussi, S. Aufderklamm, S. Mischinger, J. Stenzl, A. Gakis, G. JSLS Scientific Papers BACKGROUND AND OBJECTIVES: Many disposable platforms have been applied in laparoendoscopic single-site surgery (LESS). Besides technical issues, cost is one of the limiting factors for its widespread acceptance. The current study describes the first completely reusable LESS-platform. METHODS: We performed LESS-procedures in 52 patients including nephrectomy (18), adrenalectomy (2), partial nephrectomy (3), pyeloplasty (4), renal cyst ablation (4), pelvic lymphadenectomy (15), and lymphocele ablation (6). All procedures were conducted using a novel reusable single-port device (X-Cone, Karl-Storz) with a simplified set of instruments. We obtained perioperative and demographic data, including a visual analogue pain scale (VAS), and a complication reporting system based on Clavien grading. RESULTS: Mean age was 50.04 y. Conversion to standard laparoscopy was necessary in 3 cases and addition of a needlescopic instrument in 6 cases. There was no open conversion. Intra- and postoperative complications occurred in 3 (Clavien II in 2 and III in 1) cases. Mean operative time was 110, 90, and 89 min, and hospital stay was 4.9, 3.1, and 3.6 d for nephrectomy, pelvic lymphadenectomy, and pyeloplasty, respectively. Mean VAS was 2.13, 1.07, and 1.5 while blood loss was 81.3 mL, 25.67 mL, and 17.5 mL, respectively. Mean lymph node yield was 15 (range, 8 to 21). CONCLUSIONS: A completely reusable LESS-platform is applicable to various uses in urology, yielding favorable functional and cosmetic results. Reusable materials are useful to reduce the cost of LESS, further increasing its acceptance. LESS with a completely reusable platform is more cost effective than standard laparoscopy. Society of Laparoendoscopic Surgeons 2013 /pmc/articles/PMC3771796/ /pubmed/23925023 http://dx.doi.org/10.4293/108680813X13654754534477 Text en © 2013 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/us/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Schwentner, C.
Todenhöfer, T.
Seibold, J.
Alloussi, S.
Aufderklamm, S.
Mischinger, J.
Stenzl, A.
Gakis, G.
Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title_full Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title_fullStr Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title_full_unstemmed Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title_short Cost Effective Laparoendoscopic Single-Site Surgery with a Reusable Platform
title_sort cost effective laparoendoscopic single-site surgery with a reusable platform
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3771796/
https://www.ncbi.nlm.nih.gov/pubmed/23925023
http://dx.doi.org/10.4293/108680813X13654754534477
work_keys_str_mv AT schwentnerc costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT todenhofert costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT seiboldj costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT alloussis costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT aufderklamms costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT mischingerj costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT stenzla costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform
AT gakisg costeffectivelaparoendoscopicsinglesitesurgerywithareusableplatform