Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit

PURPOSE: Stroke volume (SV) is a parameter that is being recognized as an endpoint in fluid resuscitation algorithms. Its role is now being realized as an important variable in hemodynamic assessment in various clinical scenarios such as septic and cardiogenic shocks. Direct measurement of stroke vo...

Descripción completa

Detalles Bibliográficos
Autores principales: Behnia, Mehrdad, Powell, Sherry, Fallen, Linda, Tamaddon, Houman, Behnia, Masud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Libertas Academica 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3771818/
https://www.ncbi.nlm.nih.gov/pubmed/24052694
http://dx.doi.org/10.4137/CCRPM.S12498
_version_ 1782284231515308032
author Behnia, Mehrdad
Powell, Sherry
Fallen, Linda
Tamaddon, Houman
Behnia, Masud
author_facet Behnia, Mehrdad
Powell, Sherry
Fallen, Linda
Tamaddon, Houman
Behnia, Masud
author_sort Behnia, Mehrdad
collection PubMed
description PURPOSE: Stroke volume (SV) is a parameter that is being recognized as an endpoint in fluid resuscitation algorithms. Its role is now being realized as an important variable in hemodynamic assessment in various clinical scenarios such as septic and cardiogenic shocks. Direct measurement of stroke volume (SV) and its novel corollary, stroke volume variation (SVV) derived by proprietary software, are preferred over mean cardiac output (CO) measurements because they render a more accurate reflection of hemodynamic status independent of heart rate. Flotrac-Vigileo monitor (FTV) (Edwards Lifesciences, Irvine, CA, USA) is a system that uses a complex algorithm analyzing arterial waveform to calculate SV, SVV, and CO. We assessed the feasibility of obtaining SV measurements with a portable echocardiogram and validated its accuracy with the FTV system in mechanically ventilated patients in our intensive care unit (ICU). Furthermore, we emphasized the importance of hemodynamic measurements and familiarity with critical care echocardiography for the intensivists. METHODS: Ten patients who were on mechanical ventilation were studied. A femoral arterial line was connected to the FTV system monitoring SV and CO. A portable echocardiogram (M-Turbo; Sonosite, Bothell, WA) was used to measure SV. CO was calculated by multiplying SV by heart rate. No patient had arrhythmia. We used biplane Simpson’s method of discs to calculate SV in which subtraction of end-systolic volume from end-diastolic volume yields the SV. RESULTS: The comparison of simultaneous SV and CO measurements by echocardiography with FTV showed a strong correlation between the 2. (For SV, y = 0.9545x + 3.3, R(2) = 0.98 and for CO, y = 0.9104x + 7.7074, R(2) = 0.97). CONCLUSIONS: In our small cohort, the SV and CO measured by a portable echocardiogram (Sonosite M-Turbo) appears to be closely correlated with their respective values measured by FTV. Portable echocardiography is a reliable noninvasive tool for the hemodynamic assessment of the critically ill. Its results need further validation with gold standard measures in a larger cohort of patients. However, our results suggest portable echocardiography could be an attractive tool in assessment of different hemodynamic scenarios in the critically ill.
format Online
Article
Text
id pubmed-3771818
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Libertas Academica
record_format MEDLINE/PubMed
spelling pubmed-37718182013-09-19 Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit Behnia, Mehrdad Powell, Sherry Fallen, Linda Tamaddon, Houman Behnia, Masud Clin Med Insights Circ Respir Pulm Med Original Research PURPOSE: Stroke volume (SV) is a parameter that is being recognized as an endpoint in fluid resuscitation algorithms. Its role is now being realized as an important variable in hemodynamic assessment in various clinical scenarios such as septic and cardiogenic shocks. Direct measurement of stroke volume (SV) and its novel corollary, stroke volume variation (SVV) derived by proprietary software, are preferred over mean cardiac output (CO) measurements because they render a more accurate reflection of hemodynamic status independent of heart rate. Flotrac-Vigileo monitor (FTV) (Edwards Lifesciences, Irvine, CA, USA) is a system that uses a complex algorithm analyzing arterial waveform to calculate SV, SVV, and CO. We assessed the feasibility of obtaining SV measurements with a portable echocardiogram and validated its accuracy with the FTV system in mechanically ventilated patients in our intensive care unit (ICU). Furthermore, we emphasized the importance of hemodynamic measurements and familiarity with critical care echocardiography for the intensivists. METHODS: Ten patients who were on mechanical ventilation were studied. A femoral arterial line was connected to the FTV system monitoring SV and CO. A portable echocardiogram (M-Turbo; Sonosite, Bothell, WA) was used to measure SV. CO was calculated by multiplying SV by heart rate. No patient had arrhythmia. We used biplane Simpson’s method of discs to calculate SV in which subtraction of end-systolic volume from end-diastolic volume yields the SV. RESULTS: The comparison of simultaneous SV and CO measurements by echocardiography with FTV showed a strong correlation between the 2. (For SV, y = 0.9545x + 3.3, R(2) = 0.98 and for CO, y = 0.9104x + 7.7074, R(2) = 0.97). CONCLUSIONS: In our small cohort, the SV and CO measured by a portable echocardiogram (Sonosite M-Turbo) appears to be closely correlated with their respective values measured by FTV. Portable echocardiography is a reliable noninvasive tool for the hemodynamic assessment of the critically ill. Its results need further validation with gold standard measures in a larger cohort of patients. However, our results suggest portable echocardiography could be an attractive tool in assessment of different hemodynamic scenarios in the critically ill. Libertas Academica 2013-09-08 /pmc/articles/PMC3771818/ /pubmed/24052694 http://dx.doi.org/10.4137/CCRPM.S12498 Text en © 2013 the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article published under the Creative Commons CC-BY-NC 3.0 license.
spellingShingle Original Research
Behnia, Mehrdad
Powell, Sherry
Fallen, Linda
Tamaddon, Houman
Behnia, Masud
Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title_full Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title_fullStr Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title_full_unstemmed Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title_short Correlation of Stroke Volume Measurement between Sonosite Portable Echocardiogram and Edwards Flotrac Sensor-Vigileo Monitor in an Intensive Care Unit
title_sort correlation of stroke volume measurement between sonosite portable echocardiogram and edwards flotrac sensor-vigileo monitor in an intensive care unit
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3771818/
https://www.ncbi.nlm.nih.gov/pubmed/24052694
http://dx.doi.org/10.4137/CCRPM.S12498
work_keys_str_mv AT behniamehrdad correlationofstrokevolumemeasurementbetweensonositeportableechocardiogramandedwardsflotracsensorvigileomonitorinanintensivecareunit
AT powellsherry correlationofstrokevolumemeasurementbetweensonositeportableechocardiogramandedwardsflotracsensorvigileomonitorinanintensivecareunit
AT fallenlinda correlationofstrokevolumemeasurementbetweensonositeportableechocardiogramandedwardsflotracsensorvigileomonitorinanintensivecareunit
AT tamaddonhouman correlationofstrokevolumemeasurementbetweensonositeportableechocardiogramandedwardsflotracsensorvigileomonitorinanintensivecareunit
AT behniamasud correlationofstrokevolumemeasurementbetweensonositeportableechocardiogramandedwardsflotracsensorvigileomonitorinanintensivecareunit