Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: F...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3772247/ https://www.ncbi.nlm.nih.gov/pubmed/24043961 http://dx.doi.org/10.3348/kjr.2013.14.5.701 |
_version_ | 1782284297324986368 |
---|---|
author | Gwak, Yeon Joo Kim, Hye Jung Kwak, Jin Young Son, Eun Ju Ko, Kyung Hee Lee, Jin Hwa Lim, Hyo Soon Lee, You Jin Park, Ji Won Shin, Kyung Min Jang, Yun-Jin |
author_facet | Gwak, Yeon Joo Kim, Hye Jung Kwak, Jin Young Son, Eun Ju Ko, Kyung Hee Lee, Jin Hwa Lim, Hyo Soon Lee, You Jin Park, Ji Won Shin, Kyung Min Jang, Yun-Jin |
author_sort | Gwak, Yeon Joo |
collection | PubMed |
description | OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: Four hundred and sixty eight sets of film mammograms were evaluated with respect to the Korean and ACR standards for clinical image evaluation. The pass and failure rates of mammograms were compared by medical facility types. Average scores in each category of the two standards were evaluated. Receiver operating characteristic curve analysis was used to identify an optimal Korean standard pass mark by taking the ACR standard as the reference standard. RESULTS: 93.6% (438/468) of mammograms passed the Korean standard, whereas only 80.1% (375/468) passed the ACR standard (p < 0.001). Non-radiologic private clinics had the lowest pass rate (88.1%: Korean standard, 71.8%: ACR standard) and the lowest total score (76.0) by the Korean standard. Average scores of positioning were lowest (19.3/29 by the Korean standard and 3.7/5 by the ACR standard). A cutoff score of 77.0 for the Korean standard was found to correspond to a pass level when the ACR standard was applied. CONCLUSION: We suggest that tighter regulations, such as, raising the Korean pass mark, subtracting more for severe deficiencies, or considering a very low scores in even a single category as failure, are needed to improve the quality of mammography in Korea. |
format | Online Article Text |
id | pubmed-3772247 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-37722472013-09-16 Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard Gwak, Yeon Joo Kim, Hye Jung Kwak, Jin Young Son, Eun Ju Ko, Kyung Hee Lee, Jin Hwa Lim, Hyo Soon Lee, You Jin Park, Ji Won Shin, Kyung Min Jang, Yun-Jin Korean J Radiol Breast Imaging OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: Four hundred and sixty eight sets of film mammograms were evaluated with respect to the Korean and ACR standards for clinical image evaluation. The pass and failure rates of mammograms were compared by medical facility types. Average scores in each category of the two standards were evaluated. Receiver operating characteristic curve analysis was used to identify an optimal Korean standard pass mark by taking the ACR standard as the reference standard. RESULTS: 93.6% (438/468) of mammograms passed the Korean standard, whereas only 80.1% (375/468) passed the ACR standard (p < 0.001). Non-radiologic private clinics had the lowest pass rate (88.1%: Korean standard, 71.8%: ACR standard) and the lowest total score (76.0) by the Korean standard. Average scores of positioning were lowest (19.3/29 by the Korean standard and 3.7/5 by the ACR standard). A cutoff score of 77.0 for the Korean standard was found to correspond to a pass level when the ACR standard was applied. CONCLUSION: We suggest that tighter regulations, such as, raising the Korean pass mark, subtracting more for severe deficiencies, or considering a very low scores in even a single category as failure, are needed to improve the quality of mammography in Korea. The Korean Society of Radiology 2013 2013-08-30 /pmc/articles/PMC3772247/ /pubmed/24043961 http://dx.doi.org/10.3348/kjr.2013.14.5.701 Text en Copyright © 2013 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Breast Imaging Gwak, Yeon Joo Kim, Hye Jung Kwak, Jin Young Son, Eun Ju Ko, Kyung Hee Lee, Jin Hwa Lim, Hyo Soon Lee, You Jin Park, Ji Won Shin, Kyung Min Jang, Yun-Jin Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title | Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title_full | Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title_fullStr | Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title_full_unstemmed | Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title_short | Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard |
title_sort | clinical image evaluation of film mammograms in korea: comparison with the acr standard |
topic | Breast Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3772247/ https://www.ncbi.nlm.nih.gov/pubmed/24043961 http://dx.doi.org/10.3348/kjr.2013.14.5.701 |
work_keys_str_mv | AT gwakyeonjoo clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT kimhyejung clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT kwakjinyoung clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT soneunju clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT kokyunghee clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT leejinhwa clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT limhyosoon clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT leeyoujin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT parkjiwon clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT shinkyungmin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard AT jangyunjin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard |