Cargando…

Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard

OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: F...

Descripción completa

Detalles Bibliográficos
Autores principales: Gwak, Yeon Joo, Kim, Hye Jung, Kwak, Jin Young, Son, Eun Ju, Ko, Kyung Hee, Lee, Jin Hwa, Lim, Hyo Soon, Lee, You Jin, Park, Ji Won, Shin, Kyung Min, Jang, Yun-Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3772247/
https://www.ncbi.nlm.nih.gov/pubmed/24043961
http://dx.doi.org/10.3348/kjr.2013.14.5.701
_version_ 1782284297324986368
author Gwak, Yeon Joo
Kim, Hye Jung
Kwak, Jin Young
Son, Eun Ju
Ko, Kyung Hee
Lee, Jin Hwa
Lim, Hyo Soon
Lee, You Jin
Park, Ji Won
Shin, Kyung Min
Jang, Yun-Jin
author_facet Gwak, Yeon Joo
Kim, Hye Jung
Kwak, Jin Young
Son, Eun Ju
Ko, Kyung Hee
Lee, Jin Hwa
Lim, Hyo Soon
Lee, You Jin
Park, Ji Won
Shin, Kyung Min
Jang, Yun-Jin
author_sort Gwak, Yeon Joo
collection PubMed
description OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: Four hundred and sixty eight sets of film mammograms were evaluated with respect to the Korean and ACR standards for clinical image evaluation. The pass and failure rates of mammograms were compared by medical facility types. Average scores in each category of the two standards were evaluated. Receiver operating characteristic curve analysis was used to identify an optimal Korean standard pass mark by taking the ACR standard as the reference standard. RESULTS: 93.6% (438/468) of mammograms passed the Korean standard, whereas only 80.1% (375/468) passed the ACR standard (p < 0.001). Non-radiologic private clinics had the lowest pass rate (88.1%: Korean standard, 71.8%: ACR standard) and the lowest total score (76.0) by the Korean standard. Average scores of positioning were lowest (19.3/29 by the Korean standard and 3.7/5 by the ACR standard). A cutoff score of 77.0 for the Korean standard was found to correspond to a pass level when the ACR standard was applied. CONCLUSION: We suggest that tighter regulations, such as, raising the Korean pass mark, subtracting more for severe deficiencies, or considering a very low scores in even a single category as failure, are needed to improve the quality of mammography in Korea.
format Online
Article
Text
id pubmed-3772247
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-37722472013-09-16 Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard Gwak, Yeon Joo Kim, Hye Jung Kwak, Jin Young Son, Eun Ju Ko, Kyung Hee Lee, Jin Hwa Lim, Hyo Soon Lee, You Jin Park, Ji Won Shin, Kyung Min Jang, Yun-Jin Korean J Radiol Breast Imaging OBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: Four hundred and sixty eight sets of film mammograms were evaluated with respect to the Korean and ACR standards for clinical image evaluation. The pass and failure rates of mammograms were compared by medical facility types. Average scores in each category of the two standards were evaluated. Receiver operating characteristic curve analysis was used to identify an optimal Korean standard pass mark by taking the ACR standard as the reference standard. RESULTS: 93.6% (438/468) of mammograms passed the Korean standard, whereas only 80.1% (375/468) passed the ACR standard (p < 0.001). Non-radiologic private clinics had the lowest pass rate (88.1%: Korean standard, 71.8%: ACR standard) and the lowest total score (76.0) by the Korean standard. Average scores of positioning were lowest (19.3/29 by the Korean standard and 3.7/5 by the ACR standard). A cutoff score of 77.0 for the Korean standard was found to correspond to a pass level when the ACR standard was applied. CONCLUSION: We suggest that tighter regulations, such as, raising the Korean pass mark, subtracting more for severe deficiencies, or considering a very low scores in even a single category as failure, are needed to improve the quality of mammography in Korea. The Korean Society of Radiology 2013 2013-08-30 /pmc/articles/PMC3772247/ /pubmed/24043961 http://dx.doi.org/10.3348/kjr.2013.14.5.701 Text en Copyright © 2013 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Breast Imaging
Gwak, Yeon Joo
Kim, Hye Jung
Kwak, Jin Young
Son, Eun Ju
Ko, Kyung Hee
Lee, Jin Hwa
Lim, Hyo Soon
Lee, You Jin
Park, Ji Won
Shin, Kyung Min
Jang, Yun-Jin
Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title_full Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title_fullStr Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title_full_unstemmed Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title_short Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard
title_sort clinical image evaluation of film mammograms in korea: comparison with the acr standard
topic Breast Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3772247/
https://www.ncbi.nlm.nih.gov/pubmed/24043961
http://dx.doi.org/10.3348/kjr.2013.14.5.701
work_keys_str_mv AT gwakyeonjoo clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT kimhyejung clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT kwakjinyoung clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT soneunju clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT kokyunghee clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT leejinhwa clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT limhyosoon clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT leeyoujin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT parkjiwon clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT shinkyungmin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard
AT jangyunjin clinicalimageevaluationoffilmmammogramsinkoreacomparisonwiththeacrstandard