Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

OBJECTIVE: The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. METHODS: From 2010 to 2011, consecutive 222 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Myeong Jin, Lim, Yong Cheol, Oh, Se-yang, Kim, Byung Moon, Kim, Bum-soo, Shin, Yong Sam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Neurosurgical Society 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3772281/
https://www.ncbi.nlm.nih.gov/pubmed/24044075
http://dx.doi.org/10.3340/jkns.2013.54.1.19
Descripción
Sumario:OBJECTIVE: The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. METHODS: From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. RESULTS: Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was 5.0±8.7 (mean±SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was 2.1±5.4 (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. CONCLUSION: The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.