Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standa...

Descripción completa

Detalles Bibliográficos
Autores principales: Ng, Beng Kwang, Lim, Pei Shan, Shafiee, Mohamad Nasir, Abdul Ghani, Nur Azurah, Mohamed Ismail, Nor Azlin, Omar, Mohd Hashim, Muhammad Yassin, Muhammad Abdul Jamil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3773890/
https://www.ncbi.nlm.nih.gov/pubmed/24073412
http://dx.doi.org/10.1155/2013/587438
_version_ 1782284442942832640
author Ng, Beng Kwang
Lim, Pei Shan
Shafiee, Mohamad Nasir
Abdul Ghani, Nur Azurah
Mohamed Ismail, Nor Azlin
Omar, Mohd Hashim
Muhammad Yassin, Muhammad Abdul Jamil
author_facet Ng, Beng Kwang
Lim, Pei Shan
Shafiee, Mohamad Nasir
Abdul Ghani, Nur Azurah
Mohamed Ismail, Nor Azlin
Omar, Mohd Hashim
Muhammad Yassin, Muhammad Abdul Jamil
author_sort Ng, Beng Kwang
collection PubMed
description Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone.
format Online
Article
Text
id pubmed-3773890
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37738902013-09-26 Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes Ng, Beng Kwang Lim, Pei Shan Shafiee, Mohamad Nasir Abdul Ghani, Nur Azurah Mohamed Ismail, Nor Azlin Omar, Mohd Hashim Muhammad Yassin, Muhammad Abdul Jamil Biomed Res Int Research Article Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart). Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6%) had ruptured membranes, while 24 patients (11.4%) had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (179 of 179), and negative predictive value of 75.0% (24 of 32). By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187), specificity of 100% (24 of 24), positive predictive value of 100% (146 of 146), and negative predictive value of 36.9% (24 of 65) in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning), the nitrazine test alone or fern test alone. Hindawi Publishing Corporation 2013 2013-09-01 /pmc/articles/PMC3773890/ /pubmed/24073412 http://dx.doi.org/10.1155/2013/587438 Text en Copyright © 2013 Beng Kwang Ng et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ng, Beng Kwang
Lim, Pei Shan
Shafiee, Mohamad Nasir
Abdul Ghani, Nur Azurah
Mohamed Ismail, Nor Azlin
Omar, Mohd Hashim
Muhammad Yassin, Muhammad Abdul Jamil
Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title_full Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title_fullStr Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title_full_unstemmed Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title_short Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes
title_sort comparison between amnisure placental alpha microglobulin-1 rapid immunoassay and standard diagnostic methods for detection of rupture of membranes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3773890/
https://www.ncbi.nlm.nih.gov/pubmed/24073412
http://dx.doi.org/10.1155/2013/587438
work_keys_str_mv AT ngbengkwang comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT limpeishan comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT shafieemohamadnasir comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT abdulghaninurazurah comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT mohamedismailnorazlin comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT omarmohdhashim comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes
AT muhammadyassinmuhammadabduljamil comparisonbetweenamnisureplacentalalphamicroglobulin1rapidimmunoassayandstandarddiagnosticmethodsfordetectionofruptureofmembranes