Cargando…
Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging
BACKGROUND AND PURPOSE: To investigate the feasibility of direct magnetic resonance portal vein thrombosis (PVT) visualization with T2*-weighted imaging (T2*WI) without contrast agent. METHODS: Thirty patients with PVT were included in this study. All of them were imaged with contrast-enhanced CT (C...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3775116/ https://www.ncbi.nlm.nih.gov/pubmed/24046533 http://dx.doi.org/10.7150/ijms.6681 |
_version_ | 1782284583069286400 |
---|---|
author | Li, Chuanming Hu, Alice Haacke, Mark Wang, Jian Zhao, Jun Zhou, Daiquan |
author_facet | Li, Chuanming Hu, Alice Haacke, Mark Wang, Jian Zhao, Jun Zhou, Daiquan |
author_sort | Li, Chuanming |
collection | PubMed |
description | BACKGROUND AND PURPOSE: To investigate the feasibility of direct magnetic resonance portal vein thrombosis (PVT) visualization with T2*-weighted imaging (T2*WI) without contrast agent. METHODS: Thirty patients with PVT were included in this study. All of them were imaged with contrast-enhanced CT (CE-CT) as well as non-contrast MRI T1, T2 and T2*WI. Imaging data was independently analyzed by two experienced radiologists. T2*WI of all PVT was compared slice-by-slice with each of the comparison sequences (T1WI, T2WI and CE-CT) on the following categories: the location, size, boundary, and conspicuity of thrombus and portal veins. RESULTS: The average score of PVT visualization in T2*WI was higher than T1WI and T2WI in location, size, boundary and conspicuity (t = 7.54 - 84.16, P<0.05), and higher than CE-CT in boundary and conspicuity (t = 3.03- 6.98, P<0.05). For portal vein visualization, there was no significant score difference in left, middle and right portal veins between CE-CT and T2*WI (t = -1.76- 1.35, P>0.05). CONCLUSIONS: Our results suggest T2*WI can characterize PVT accurately with high quality without the use of intravenous contrast agents. |
format | Online Article Text |
id | pubmed-3775116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-37751162013-09-17 Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging Li, Chuanming Hu, Alice Haacke, Mark Wang, Jian Zhao, Jun Zhou, Daiquan Int J Med Sci Research Paper BACKGROUND AND PURPOSE: To investigate the feasibility of direct magnetic resonance portal vein thrombosis (PVT) visualization with T2*-weighted imaging (T2*WI) without contrast agent. METHODS: Thirty patients with PVT were included in this study. All of them were imaged with contrast-enhanced CT (CE-CT) as well as non-contrast MRI T1, T2 and T2*WI. Imaging data was independently analyzed by two experienced radiologists. T2*WI of all PVT was compared slice-by-slice with each of the comparison sequences (T1WI, T2WI and CE-CT) on the following categories: the location, size, boundary, and conspicuity of thrombus and portal veins. RESULTS: The average score of PVT visualization in T2*WI was higher than T1WI and T2WI in location, size, boundary and conspicuity (t = 7.54 - 84.16, P<0.05), and higher than CE-CT in boundary and conspicuity (t = 3.03- 6.98, P<0.05). For portal vein visualization, there was no significant score difference in left, middle and right portal veins between CE-CT and T2*WI (t = -1.76- 1.35, P>0.05). CONCLUSIONS: Our results suggest T2*WI can characterize PVT accurately with high quality without the use of intravenous contrast agents. Ivyspring International Publisher 2013-09-07 /pmc/articles/PMC3775116/ /pubmed/24046533 http://dx.doi.org/10.7150/ijms.6681 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited. |
spellingShingle | Research Paper Li, Chuanming Hu, Alice Haacke, Mark Wang, Jian Zhao, Jun Zhou, Daiquan Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title | Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title_full | Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title_fullStr | Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title_full_unstemmed | Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title_short | Direct Portal Vein Thrombosis Visualization with T2*-Weighted Magnetic Resonance Imaging |
title_sort | direct portal vein thrombosis visualization with t2*-weighted magnetic resonance imaging |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3775116/ https://www.ncbi.nlm.nih.gov/pubmed/24046533 http://dx.doi.org/10.7150/ijms.6681 |
work_keys_str_mv | AT lichuanming directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging AT hualice directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging AT haackemark directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging AT wangjian directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging AT zhaojun directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging AT zhoudaiquan directportalveinthrombosisvisualizationwitht2weightedmagneticresonanceimaging |