Cargando…

Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney

INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Rong, Xu, Fan-hua, Yao, Ming-hua, Xie, Juan, Hu, Bing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3776188/
https://www.ncbi.nlm.nih.gov/pubmed/24049518
http://dx.doi.org/10.5114/aoms.2013.37271
_version_ 1782477446377897984
author Wu, Rong
Xu, Fan-hua
Yao, Ming-hua
Xie, Juan
Hu, Bing
author_facet Wu, Rong
Xu, Fan-hua
Yao, Ming-hua
Xie, Juan
Hu, Bing
author_sort Wu, Rong
collection PubMed
description INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation (RFA) to generate renal lesions. Lesions were evaluated by conventional 2D ultrasound and contrast-enhanced ultrasonography (CEUS) at 1 day, 1 week, 1 month and 3 months after RFA, and the results were compared to gross pathology. RESULTS: One day and 1 week after RFA, renal lesions were wedge-shaped in the gross dissection cross-sectional profiles. Conventional ultrasound could not indicate the extent of the lesions; however, CEUS could exactly delineate the lesion shape and size. At 1 and 3 months, lesions were observed as hyperechogenic areas on conventional ultrasound, and as small perfusion defects on CEUS. The differences in the lesion measurements obtained by CEUS and in pathological specimens were not statistically significant (p > 0.05). CONCLUSIONS: The conclusion could be deduced from the study that SonoVue-enhanced ultrasonography was effective for the follow-up of normal rabbit kidney percutaneous radiofrequency ablation.
format Online
Article
Text
id pubmed-3776188
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-37761882013-09-18 Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney Wu, Rong Xu, Fan-hua Yao, Ming-hua Xie, Juan Hu, Bing Arch Med Sci Experimental Research INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation (RFA) to generate renal lesions. Lesions were evaluated by conventional 2D ultrasound and contrast-enhanced ultrasonography (CEUS) at 1 day, 1 week, 1 month and 3 months after RFA, and the results were compared to gross pathology. RESULTS: One day and 1 week after RFA, renal lesions were wedge-shaped in the gross dissection cross-sectional profiles. Conventional ultrasound could not indicate the extent of the lesions; however, CEUS could exactly delineate the lesion shape and size. At 1 and 3 months, lesions were observed as hyperechogenic areas on conventional ultrasound, and as small perfusion defects on CEUS. The differences in the lesion measurements obtained by CEUS and in pathological specimens were not statistically significant (p > 0.05). CONCLUSIONS: The conclusion could be deduced from the study that SonoVue-enhanced ultrasonography was effective for the follow-up of normal rabbit kidney percutaneous radiofrequency ablation. Termedia Publishing House 2013-08-29 2013-08-30 /pmc/articles/PMC3776188/ /pubmed/24049518 http://dx.doi.org/10.5114/aoms.2013.37271 Text en Copyright © 2013 Termedia & Banach http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Experimental Research
Wu, Rong
Xu, Fan-hua
Yao, Ming-hua
Xie, Juan
Hu, Bing
Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title_full Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title_fullStr Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title_full_unstemmed Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title_short Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
title_sort contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
topic Experimental Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3776188/
https://www.ncbi.nlm.nih.gov/pubmed/24049518
http://dx.doi.org/10.5114/aoms.2013.37271
work_keys_str_mv AT wurong contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney
AT xufanhua contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney
AT yaominghua contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney
AT xiejuan contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney
AT hubing contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney