Cargando…
Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney
INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3776188/ https://www.ncbi.nlm.nih.gov/pubmed/24049518 http://dx.doi.org/10.5114/aoms.2013.37271 |
_version_ | 1782477446377897984 |
---|---|
author | Wu, Rong Xu, Fan-hua Yao, Ming-hua Xie, Juan Hu, Bing |
author_facet | Wu, Rong Xu, Fan-hua Yao, Ming-hua Xie, Juan Hu, Bing |
author_sort | Wu, Rong |
collection | PubMed |
description | INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation (RFA) to generate renal lesions. Lesions were evaluated by conventional 2D ultrasound and contrast-enhanced ultrasonography (CEUS) at 1 day, 1 week, 1 month and 3 months after RFA, and the results were compared to gross pathology. RESULTS: One day and 1 week after RFA, renal lesions were wedge-shaped in the gross dissection cross-sectional profiles. Conventional ultrasound could not indicate the extent of the lesions; however, CEUS could exactly delineate the lesion shape and size. At 1 and 3 months, lesions were observed as hyperechogenic areas on conventional ultrasound, and as small perfusion defects on CEUS. The differences in the lesion measurements obtained by CEUS and in pathological specimens were not statistically significant (p > 0.05). CONCLUSIONS: The conclusion could be deduced from the study that SonoVue-enhanced ultrasonography was effective for the follow-up of normal rabbit kidney percutaneous radiofrequency ablation. |
format | Online Article Text |
id | pubmed-3776188 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-37761882013-09-18 Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney Wu, Rong Xu, Fan-hua Yao, Ming-hua Xie, Juan Hu, Bing Arch Med Sci Experimental Research INTRODUCTION: The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS: New Zealand rabbits (28) underwent percutaneous radiofrequency ablation (RFA) to generate renal lesions. Lesions were evaluated by conventional 2D ultrasound and contrast-enhanced ultrasonography (CEUS) at 1 day, 1 week, 1 month and 3 months after RFA, and the results were compared to gross pathology. RESULTS: One day and 1 week after RFA, renal lesions were wedge-shaped in the gross dissection cross-sectional profiles. Conventional ultrasound could not indicate the extent of the lesions; however, CEUS could exactly delineate the lesion shape and size. At 1 and 3 months, lesions were observed as hyperechogenic areas on conventional ultrasound, and as small perfusion defects on CEUS. The differences in the lesion measurements obtained by CEUS and in pathological specimens were not statistically significant (p > 0.05). CONCLUSIONS: The conclusion could be deduced from the study that SonoVue-enhanced ultrasonography was effective for the follow-up of normal rabbit kidney percutaneous radiofrequency ablation. Termedia Publishing House 2013-08-29 2013-08-30 /pmc/articles/PMC3776188/ /pubmed/24049518 http://dx.doi.org/10.5114/aoms.2013.37271 Text en Copyright © 2013 Termedia & Banach http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Experimental Research Wu, Rong Xu, Fan-hua Yao, Ming-hua Xie, Juan Hu, Bing Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title | Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title_full | Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title_fullStr | Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title_full_unstemmed | Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title_short | Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
title_sort | contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney |
topic | Experimental Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3776188/ https://www.ncbi.nlm.nih.gov/pubmed/24049518 http://dx.doi.org/10.5114/aoms.2013.37271 |
work_keys_str_mv | AT wurong contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney AT xufanhua contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney AT yaominghua contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney AT xiejuan contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney AT hubing contrastenhancedultrasonographyfollowupafterradiofrequencyablationinnormalrabbitkidney |