Cargando…

Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()

BACKGROUND AND PURPOSE: Increased blood–brain barrier permeability is believed to be associated with complications following acute ischemic stroke and with infarct expansion. Measurement of blood–brain barrier permeability requires a delayed image acquisition methodology, which prolongs examination...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Giang Truong, Coulthard, Alan, Wong, Andrew, Sheikh, Nabeel, Henderson, Robert, O'Sullivan, John D., Reutens, David C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777785/
https://www.ncbi.nlm.nih.gov/pubmed/24179816
http://dx.doi.org/10.1016/j.nicl.2013.04.004
_version_ 1782285011310870528
author Nguyen, Giang Truong
Coulthard, Alan
Wong, Andrew
Sheikh, Nabeel
Henderson, Robert
O'Sullivan, John D.
Reutens, David C.
author_facet Nguyen, Giang Truong
Coulthard, Alan
Wong, Andrew
Sheikh, Nabeel
Henderson, Robert
O'Sullivan, John D.
Reutens, David C.
author_sort Nguyen, Giang Truong
collection PubMed
description BACKGROUND AND PURPOSE: Increased blood–brain barrier permeability is believed to be associated with complications following acute ischemic stroke and with infarct expansion. Measurement of blood–brain barrier permeability requires a delayed image acquisition methodology, which prolongs examination time, increasing the likelihood of movement artefacts and radiation dose. Existing quantitative methods overestimate blood–brain barrier permeability when early phase CT perfusion data are used. The purpose of this study is to develop a method that yields the correct blood–brain barrier permeability value using first-pass perfusion CT data. METHODS: We acquired 43 CT perfusion datasets, comprising experimental (n = 30) and validation subject groups (n = 13). The Gjedde–Patlak method was used to estimate blood–brain barrier permeability using first-pass (30–60 s after contrast administration) and delayed phase (30–200 s) data. In the experimental group, linear regression was used to obtain a function predicting first-pass blood–brain barrier permeability estimates from delayed phase estimates in each stroke compartment. The reliability of prediction with this function was then tested using data from the validation group. RESULTS: The predicted delayed phase blood–brain barrier permeability was strongly correlated with the measured delayed phase value (r = 0.67 and 0.6 for experimental and validation group respectively; p < 0.01). Predicted and measured delayed phase blood–brain barrier permeability in each stroke compartment were not significantly different in both experimental and validation groups. CONCLUSION: We have developed a method of estimating blood–brain barrier permeability using first-pass perfusion CT data. This predictive method allows reliable blood–brain barrier permeability estimation within standard acquisition time, minimizing the likelihood of motion artefacts thereby improving image quality and reducing radiation dose.
format Online
Article
Text
id pubmed-3777785
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-37777852013-10-31 Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data() Nguyen, Giang Truong Coulthard, Alan Wong, Andrew Sheikh, Nabeel Henderson, Robert O'Sullivan, John D. Reutens, David C. Neuroimage Clin Article BACKGROUND AND PURPOSE: Increased blood–brain barrier permeability is believed to be associated with complications following acute ischemic stroke and with infarct expansion. Measurement of blood–brain barrier permeability requires a delayed image acquisition methodology, which prolongs examination time, increasing the likelihood of movement artefacts and radiation dose. Existing quantitative methods overestimate blood–brain barrier permeability when early phase CT perfusion data are used. The purpose of this study is to develop a method that yields the correct blood–brain barrier permeability value using first-pass perfusion CT data. METHODS: We acquired 43 CT perfusion datasets, comprising experimental (n = 30) and validation subject groups (n = 13). The Gjedde–Patlak method was used to estimate blood–brain barrier permeability using first-pass (30–60 s after contrast administration) and delayed phase (30–200 s) data. In the experimental group, linear regression was used to obtain a function predicting first-pass blood–brain barrier permeability estimates from delayed phase estimates in each stroke compartment. The reliability of prediction with this function was then tested using data from the validation group. RESULTS: The predicted delayed phase blood–brain barrier permeability was strongly correlated with the measured delayed phase value (r = 0.67 and 0.6 for experimental and validation group respectively; p < 0.01). Predicted and measured delayed phase blood–brain barrier permeability in each stroke compartment were not significantly different in both experimental and validation groups. CONCLUSION: We have developed a method of estimating blood–brain barrier permeability using first-pass perfusion CT data. This predictive method allows reliable blood–brain barrier permeability estimation within standard acquisition time, minimizing the likelihood of motion artefacts thereby improving image quality and reducing radiation dose. Elsevier 2013-04-22 /pmc/articles/PMC3777785/ /pubmed/24179816 http://dx.doi.org/10.1016/j.nicl.2013.04.004 Text en © 2013 The Authors http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Nguyen, Giang Truong
Coulthard, Alan
Wong, Andrew
Sheikh, Nabeel
Henderson, Robert
O'Sullivan, John D.
Reutens, David C.
Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title_full Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title_fullStr Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title_full_unstemmed Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title_short Measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion CT data()
title_sort measurement of blood–brain barrier permeability in acute ischemic stroke using standard first-pass perfusion ct data()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777785/
https://www.ncbi.nlm.nih.gov/pubmed/24179816
http://dx.doi.org/10.1016/j.nicl.2013.04.004
work_keys_str_mv AT nguyengiangtruong measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT coulthardalan measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT wongandrew measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT sheikhnabeel measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT hendersonrobert measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT osullivanjohnd measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata
AT reutensdavidc measurementofbloodbrainbarrierpermeabilityinacuteischemicstrokeusingstandardfirstpassperfusionctdata