Electrophysiological responses to emotional prosody perception in cochlear implant users()

The present electroencephalographic (EEG) study investigated the ability of cochlear implant (CI) users to recognize emotional prosody. Two CI speech-processing strategies were compared: the ACE (Advance Combination Encoder) and the newly developed MP3000. Semantically neutral sentences spoken in th...

Descripción completa

Detalles Bibliográficos
Autores principales: Agrawal, D., Thorne, J.D., Viola, F.C., Timm, L., Debener, S., Büchner, A., Dengler, R., Wittfoth, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777796/
https://www.ncbi.nlm.nih.gov/pubmed/24179776
http://dx.doi.org/10.1016/j.nicl.2013.01.001
_version_ 1782285013920776192
author Agrawal, D.
Thorne, J.D.
Viola, F.C.
Timm, L.
Debener, S.
Büchner, A.
Dengler, R.
Wittfoth, M.
author_facet Agrawal, D.
Thorne, J.D.
Viola, F.C.
Timm, L.
Debener, S.
Büchner, A.
Dengler, R.
Wittfoth, M.
author_sort Agrawal, D.
collection PubMed
description The present electroencephalographic (EEG) study investigated the ability of cochlear implant (CI) users to recognize emotional prosody. Two CI speech-processing strategies were compared: the ACE (Advance Combination Encoder) and the newly developed MP3000. Semantically neutral sentences spoken in three different emotional prosodies (neutral, angry, happy) were presented to 20 post-lingually deafened CI users and age-matched normal-hearing controls. Event related potentials (ERPs) were recorded to study the N100 and the P200 responses. In addition, event-related spectral power modulations were calculated to study the brain activity corresponding to the recognition of prosody in earlier (0–400) as well as later (600–1200) part of the stimuli where the prosodic features differed maximally. CI users with MP3000 strategy showed a higher proportion of correctly recognized prosodic information compared to the ACE strategy users. Our ERP results demonstrated that emotional prosody elicited significant N100 and P200 peaks. Furthermore, the P200 amplitude in response to happy prosodic information was significantly more positive for the MP3000 strategy compared to the ACE strategy. On spectral power analysis, two typical gamma activities were observed in the MP3000 users only: (1) an early gamma activity in the 100–250 ms time window reflecting bottom–up attention regulation; and (2) a late gamma activity between 900 and 1100 ms post-stimulus onset, probably reflecting top–down cognitive control. Our study suggests that the MP3000 strategy is better than ACE in regard to happy prosody perception. Furthermore, we show that EEG is a useful tool that, in combination with behavioral analysis, can reveal differences between two CI processing strategies for coding of prosody-specific features of language.
format Online
Article
Text
id pubmed-3777796
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-37777962013-10-31 Electrophysiological responses to emotional prosody perception in cochlear implant users() Agrawal, D. Thorne, J.D. Viola, F.C. Timm, L. Debener, S. Büchner, A. Dengler, R. Wittfoth, M. Neuroimage Clin Article The present electroencephalographic (EEG) study investigated the ability of cochlear implant (CI) users to recognize emotional prosody. Two CI speech-processing strategies were compared: the ACE (Advance Combination Encoder) and the newly developed MP3000. Semantically neutral sentences spoken in three different emotional prosodies (neutral, angry, happy) were presented to 20 post-lingually deafened CI users and age-matched normal-hearing controls. Event related potentials (ERPs) were recorded to study the N100 and the P200 responses. In addition, event-related spectral power modulations were calculated to study the brain activity corresponding to the recognition of prosody in earlier (0–400) as well as later (600–1200) part of the stimuli where the prosodic features differed maximally. CI users with MP3000 strategy showed a higher proportion of correctly recognized prosodic information compared to the ACE strategy users. Our ERP results demonstrated that emotional prosody elicited significant N100 and P200 peaks. Furthermore, the P200 amplitude in response to happy prosodic information was significantly more positive for the MP3000 strategy compared to the ACE strategy. On spectral power analysis, two typical gamma activities were observed in the MP3000 users only: (1) an early gamma activity in the 100–250 ms time window reflecting bottom–up attention regulation; and (2) a late gamma activity between 900 and 1100 ms post-stimulus onset, probably reflecting top–down cognitive control. Our study suggests that the MP3000 strategy is better than ACE in regard to happy prosody perception. Furthermore, we show that EEG is a useful tool that, in combination with behavioral analysis, can reveal differences between two CI processing strategies for coding of prosody-specific features of language. Elsevier 2013-01-14 /pmc/articles/PMC3777796/ /pubmed/24179776 http://dx.doi.org/10.1016/j.nicl.2013.01.001 Text en © 2013 The Authors http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Agrawal, D.
Thorne, J.D.
Viola, F.C.
Timm, L.
Debener, S.
Büchner, A.
Dengler, R.
Wittfoth, M.
Electrophysiological responses to emotional prosody perception in cochlear implant users()
title Electrophysiological responses to emotional prosody perception in cochlear implant users()
title_full Electrophysiological responses to emotional prosody perception in cochlear implant users()
title_fullStr Electrophysiological responses to emotional prosody perception in cochlear implant users()
title_full_unstemmed Electrophysiological responses to emotional prosody perception in cochlear implant users()
title_short Electrophysiological responses to emotional prosody perception in cochlear implant users()
title_sort electrophysiological responses to emotional prosody perception in cochlear implant users()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777796/
https://www.ncbi.nlm.nih.gov/pubmed/24179776
http://dx.doi.org/10.1016/j.nicl.2013.01.001
work_keys_str_mv AT agrawald electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT thornejd electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT violafc electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT timml electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT debeners electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT buchnera electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT denglerr electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers
AT wittfothm electrophysiologicalresponsestoemotionalprosodyperceptionincochlearimplantusers