Cargando…

Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

INTRODUCTION: The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total...

Descripción completa

Detalles Bibliográficos
Autores principales: Casiraghi, Francesca, Lertwattanarak, Raweewan, Luzi, Livio, Chavez, Alberto O., Davalli, Alberto M., Naegelin, Terry, Comuzzie, Anthony G., Frost, Patricia, Musi, Nicolas, Folli, Franco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777938/
https://www.ncbi.nlm.nih.gov/pubmed/24069218
http://dx.doi.org/10.1371/journal.pone.0073651
_version_ 1782285038400831488
author Casiraghi, Francesca
Lertwattanarak, Raweewan
Luzi, Livio
Chavez, Alberto O.
Davalli, Alberto M.
Naegelin, Terry
Comuzzie, Anthony G.
Frost, Patricia
Musi, Nicolas
Folli, Franco
author_facet Casiraghi, Francesca
Lertwattanarak, Raweewan
Luzi, Livio
Chavez, Alberto O.
Davalli, Alberto M.
Naegelin, Terry
Comuzzie, Anthony G.
Frost, Patricia
Musi, Nicolas
Folli, Franco
author_sort Casiraghi, Francesca
collection PubMed
description INTRODUCTION: The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. METHODS: We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. RESULTS: In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. CONCLUSION: SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with “gold standard”, IC, in humans.
format Online
Article
Text
id pubmed-3777938
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37779382013-09-25 Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry Casiraghi, Francesca Lertwattanarak, Raweewan Luzi, Livio Chavez, Alberto O. Davalli, Alberto M. Naegelin, Terry Comuzzie, Anthony G. Frost, Patricia Musi, Nicolas Folli, Franco PLoS One Research Article INTRODUCTION: The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. METHODS: We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. RESULTS: In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. CONCLUSION: SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with “gold standard”, IC, in humans. Public Library of Science 2013-09-19 /pmc/articles/PMC3777938/ /pubmed/24069218 http://dx.doi.org/10.1371/journal.pone.0073651 Text en © 2013 Casiraghi et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Casiraghi, Francesca
Lertwattanarak, Raweewan
Luzi, Livio
Chavez, Alberto O.
Davalli, Alberto M.
Naegelin, Terry
Comuzzie, Anthony G.
Frost, Patricia
Musi, Nicolas
Folli, Franco
Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title_full Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title_fullStr Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title_full_unstemmed Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title_short Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry
title_sort energy expenditure evaluation in humans and non-human primates by sensewear armband. validation of energy expenditure evaluation by sensewear armband by direct comparison with indirect calorimetry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3777938/
https://www.ncbi.nlm.nih.gov/pubmed/24069218
http://dx.doi.org/10.1371/journal.pone.0073651
work_keys_str_mv AT casiraghifrancesca energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT lertwattanarakraweewan energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT luzilivio energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT chavezalbertoo energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT davallialbertom energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT naegelinterry energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT comuzzieanthonyg energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT frostpatricia energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT musinicolas energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry
AT follifranco energyexpenditureevaluationinhumansandnonhumanprimatesbysenseweararmbandvalidationofenergyexpenditureevaluationbysenseweararmbandbydirectcomparisonwithindirectcalorimetry