Cargando…

Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device

BACKGROUND: The pipeline embolization device (PED) provides effective, durable and safe endovascular reconstruction of large and giant intracranial aneurysms. However, 80% of all cerebral aneurysms found in the general population are less than 10 mm in size. Treatment of small aneurysms (<10 mm)...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Li-Mei, Colby, Geoffrey P., Kim, Jennifer E., Huang, Judy, Tamargo, Rafael J., Coon, Alexander L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3779399/
https://www.ncbi.nlm.nih.gov/pubmed/24083050
http://dx.doi.org/10.4103/2152-7806.117711
Descripción
Sumario:BACKGROUND: The pipeline embolization device (PED) provides effective, durable and safe endovascular reconstruction of large and giant intracranial aneurysms. However, 80% of all cerebral aneurysms found in the general population are less than 10 mm in size. Treatment of small aneurysms (<10 mm) with flow diverters may be advantageous over endosaccular modalities that carry risks of procedural rupture during aneurysm access or coil placement. METHODS: We retrospectively reviewed a prospective, single-center aneurysm database to identify all patients with small (<10 mm) internal carotid artery (ICA) aneurysms who underwent endovascular treatment using the PED. Patient demographics, aneurysm characteristics, procedural details, complications, and technical and clinical outcomes were analyzed. RESULTS: Forty-four cases were performed in 41 patients (age range 31-78 years). PED was successfully implanted in 42 cases. A single PED was used in 37/42 (88%) cases. Mean postprocedure hospital stay was 1.7 ± 0.3 days and 98% of patients were discharged home. Major complication occurred in one patient (2.3%), who died of early subarachnoid hemorrhage. Transient neurological deficit, delayed intracerebral hemorrhage (asymptomatic), and delayed groin infection occurred in one patient each. Follow-up rate was 91.8% (45 aneurysms in 35 patients) with a mean follow-up of 4.0 ± 1.9 months. By 6 months post-PED implantation, angiographic success (complete or near complete aneurysm occlusion) was observed in 80%. Mild (<50%), asymptomatic, nonflow limiting in-stent stenosis was observed in 5.4% (2/37 cases). All the 35 patients with follow-up remained at preprocedure neurological baseline. CONCLUSION: Small (<10 mm) ICA aneurysm treatment with PED implantation is safe and carries a high rate of early angiographic success.