Cargando…
Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device
BACKGROUND: The pipeline embolization device (PED) provides effective, durable and safe endovascular reconstruction of large and giant intracranial aneurysms. However, 80% of all cerebral aneurysms found in the general population are less than 10 mm in size. Treatment of small aneurysms (<10 mm)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3779399/ https://www.ncbi.nlm.nih.gov/pubmed/24083050 http://dx.doi.org/10.4103/2152-7806.117711 |
_version_ | 1782285241863372800 |
---|---|
author | Lin, Li-Mei Colby, Geoffrey P. Kim, Jennifer E. Huang, Judy Tamargo, Rafael J. Coon, Alexander L. |
author_facet | Lin, Li-Mei Colby, Geoffrey P. Kim, Jennifer E. Huang, Judy Tamargo, Rafael J. Coon, Alexander L. |
author_sort | Lin, Li-Mei |
collection | PubMed |
description | BACKGROUND: The pipeline embolization device (PED) provides effective, durable and safe endovascular reconstruction of large and giant intracranial aneurysms. However, 80% of all cerebral aneurysms found in the general population are less than 10 mm in size. Treatment of small aneurysms (<10 mm) with flow diverters may be advantageous over endosaccular modalities that carry risks of procedural rupture during aneurysm access or coil placement. METHODS: We retrospectively reviewed a prospective, single-center aneurysm database to identify all patients with small (<10 mm) internal carotid artery (ICA) aneurysms who underwent endovascular treatment using the PED. Patient demographics, aneurysm characteristics, procedural details, complications, and technical and clinical outcomes were analyzed. RESULTS: Forty-four cases were performed in 41 patients (age range 31-78 years). PED was successfully implanted in 42 cases. A single PED was used in 37/42 (88%) cases. Mean postprocedure hospital stay was 1.7 ± 0.3 days and 98% of patients were discharged home. Major complication occurred in one patient (2.3%), who died of early subarachnoid hemorrhage. Transient neurological deficit, delayed intracerebral hemorrhage (asymptomatic), and delayed groin infection occurred in one patient each. Follow-up rate was 91.8% (45 aneurysms in 35 patients) with a mean follow-up of 4.0 ± 1.9 months. By 6 months post-PED implantation, angiographic success (complete or near complete aneurysm occlusion) was observed in 80%. Mild (<50%), asymptomatic, nonflow limiting in-stent stenosis was observed in 5.4% (2/37 cases). All the 35 patients with follow-up remained at preprocedure neurological baseline. CONCLUSION: Small (<10 mm) ICA aneurysm treatment with PED implantation is safe and carries a high rate of early angiographic success. |
format | Online Article Text |
id | pubmed-3779399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-37793992013-09-30 Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device Lin, Li-Mei Colby, Geoffrey P. Kim, Jennifer E. Huang, Judy Tamargo, Rafael J. Coon, Alexander L. Surg Neurol Int Original Article BACKGROUND: The pipeline embolization device (PED) provides effective, durable and safe endovascular reconstruction of large and giant intracranial aneurysms. However, 80% of all cerebral aneurysms found in the general population are less than 10 mm in size. Treatment of small aneurysms (<10 mm) with flow diverters may be advantageous over endosaccular modalities that carry risks of procedural rupture during aneurysm access or coil placement. METHODS: We retrospectively reviewed a prospective, single-center aneurysm database to identify all patients with small (<10 mm) internal carotid artery (ICA) aneurysms who underwent endovascular treatment using the PED. Patient demographics, aneurysm characteristics, procedural details, complications, and technical and clinical outcomes were analyzed. RESULTS: Forty-four cases were performed in 41 patients (age range 31-78 years). PED was successfully implanted in 42 cases. A single PED was used in 37/42 (88%) cases. Mean postprocedure hospital stay was 1.7 ± 0.3 days and 98% of patients were discharged home. Major complication occurred in one patient (2.3%), who died of early subarachnoid hemorrhage. Transient neurological deficit, delayed intracerebral hemorrhage (asymptomatic), and delayed groin infection occurred in one patient each. Follow-up rate was 91.8% (45 aneurysms in 35 patients) with a mean follow-up of 4.0 ± 1.9 months. By 6 months post-PED implantation, angiographic success (complete or near complete aneurysm occlusion) was observed in 80%. Mild (<50%), asymptomatic, nonflow limiting in-stent stenosis was observed in 5.4% (2/37 cases). All the 35 patients with follow-up remained at preprocedure neurological baseline. CONCLUSION: Small (<10 mm) ICA aneurysm treatment with PED implantation is safe and carries a high rate of early angiographic success. Medknow Publications & Media Pvt Ltd 2013-09-06 /pmc/articles/PMC3779399/ /pubmed/24083050 http://dx.doi.org/10.4103/2152-7806.117711 Text en Copyright: © 2013 Lin L http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Article Lin, Li-Mei Colby, Geoffrey P. Kim, Jennifer E. Huang, Judy Tamargo, Rafael J. Coon, Alexander L. Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title | Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title_full | Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title_fullStr | Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title_full_unstemmed | Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title_short | Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
title_sort | immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3779399/ https://www.ncbi.nlm.nih.gov/pubmed/24083050 http://dx.doi.org/10.4103/2152-7806.117711 |
work_keys_str_mv | AT linlimei immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice AT colbygeoffreyp immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice AT kimjennifere immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice AT huangjudy immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice AT tamargorafaelj immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice AT coonalexanderl immediateandfollowupresultsfor44consecutivecasesofsmall10mminternalcarotidarteryaneurysmstreatedwiththepipelineembolizationdevice |