A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application
Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liqui...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3779794/ https://www.ncbi.nlm.nih.gov/pubmed/24078740 http://dx.doi.org/10.1007/s10337-013-2430-x |
_version_ | 1782285268663926784 |
---|---|
author | Hałka-Grysińska, Aneta Ślązak, Piotr Torbicz, Andrzej Sajewicz, Mieczysław Dzido, Tadeusz H. |
author_facet | Hałka-Grysińska, Aneta Ślązak, Piotr Torbicz, Andrzej Sajewicz, Mieczysław Dzido, Tadeusz H. |
author_sort | Hałka-Grysińska, Aneta |
collection | PubMed |
description | Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique. |
format | Online Article Text |
id | pubmed-3779794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-37797942013-09-25 A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application Hałka-Grysińska, Aneta Ślązak, Piotr Torbicz, Andrzej Sajewicz, Mieczysław Dzido, Tadeusz H. Chromatographia Original Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique. Springer Berlin Heidelberg 2013-03-05 2013 /pmc/articles/PMC3779794/ /pubmed/24078740 http://dx.doi.org/10.1007/s10337-013-2430-x Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Hałka-Grysińska, Aneta Ślązak, Piotr Torbicz, Andrzej Sajewicz, Mieczysław Dzido, Tadeusz H. A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title | A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title_full | A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title_fullStr | A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title_full_unstemmed | A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title_short | A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application |
title_sort | modified device for pressurized planar electrochromatography and preliminary results with on-line sample application |
topic | Original |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3779794/ https://www.ncbi.nlm.nih.gov/pubmed/24078740 http://dx.doi.org/10.1007/s10337-013-2430-x |
work_keys_str_mv | AT hałkagrysinskaaneta amodifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT slazakpiotr amodifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT torbiczandrzej amodifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT sajewiczmieczysław amodifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT dzidotadeuszh amodifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT hałkagrysinskaaneta modifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT slazakpiotr modifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT torbiczandrzej modifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT sajewiczmieczysław modifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication AT dzidotadeuszh modifieddeviceforpressurizedplanarelectrochromatographyandpreliminaryresultswithonlinesampleapplication |