Cargando…

Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi

OBJECTIVES: To compare image quality on computed tomographic (CT) images acquired with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) techniques in CT kidney/ureter/bladder (KUB) examination. METHODS: Eighteen pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Vardhanabhuti, Varut, Ilyas, Sumaira, Gutteridge, Catherine, Freeman, Simon J., Roobottom, Carl A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3781247/
https://www.ncbi.nlm.nih.gov/pubmed/23929357
http://dx.doi.org/10.1007/s13244-013-0273-5
_version_ 1782285393055449088
author Vardhanabhuti, Varut
Ilyas, Sumaira
Gutteridge, Catherine
Freeman, Simon J.
Roobottom, Carl A.
author_facet Vardhanabhuti, Varut
Ilyas, Sumaira
Gutteridge, Catherine
Freeman, Simon J.
Roobottom, Carl A.
author_sort Vardhanabhuti, Varut
collection PubMed
description OBJECTIVES: To compare image quality on computed tomographic (CT) images acquired with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) techniques in CT kidney/ureter/bladder (KUB) examination. METHODS: Eighteen patients underwent standard protocol CT KUB at our institution. The same raw data were reconstructed using FBP, ASIR and MBIR. Objective [mean image noise, contrast-to-noise ratio (CNR) for kidney and mean attenuation values of subcutaneous fat] and subjective image parameters (image noise, image contrast, overall visibility of kidneys/ureters/bladder, visibility of small structures, and overall diagnostic confidence) were assessed using a scoring system from 1 (best) to 5 (worst). RESULTS: Objective image measurements revealed significantly less image noise and higher CNR and the same fat attenuation values for the MBIR technique (P < 0.05). MBIR scored best in all the subjective image parameters (P < 0.001) with averages ranging between 2.05–2.73 for MBIR, 2.95–3.10 for ASIR and 3.08–3.31 for FBP. No significant difference was observed between FBP and ASIR (P > 0.05), while there was a significant difference between ASIR vs. MBIR (P < 0.05). The mean effective dose was 3 mSv. CONCLUSION: MBIR shows superior reduction in noise and improved image quality (both objective and subjective analysis) compared with ASIR and FBP CT KUB examinations. MAIN MESSAGES: • There are many reconstruction options in CT. • Novel model-based iterative reconstruction (MBIR) showed the least noise and optimal image quality. • For CT of the kidneys/ureters/bladder, MBIR should be utilised, if available. • Further studies to reduce the dose while maintaining image quality should be pursued.
format Online
Article
Text
id pubmed-3781247
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-37812472013-09-25 Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi Vardhanabhuti, Varut Ilyas, Sumaira Gutteridge, Catherine Freeman, Simon J. Roobottom, Carl A. Insights Imaging Original Article OBJECTIVES: To compare image quality on computed tomographic (CT) images acquired with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) techniques in CT kidney/ureter/bladder (KUB) examination. METHODS: Eighteen patients underwent standard protocol CT KUB at our institution. The same raw data were reconstructed using FBP, ASIR and MBIR. Objective [mean image noise, contrast-to-noise ratio (CNR) for kidney and mean attenuation values of subcutaneous fat] and subjective image parameters (image noise, image contrast, overall visibility of kidneys/ureters/bladder, visibility of small structures, and overall diagnostic confidence) were assessed using a scoring system from 1 (best) to 5 (worst). RESULTS: Objective image measurements revealed significantly less image noise and higher CNR and the same fat attenuation values for the MBIR technique (P < 0.05). MBIR scored best in all the subjective image parameters (P < 0.001) with averages ranging between 2.05–2.73 for MBIR, 2.95–3.10 for ASIR and 3.08–3.31 for FBP. No significant difference was observed between FBP and ASIR (P > 0.05), while there was a significant difference between ASIR vs. MBIR (P < 0.05). The mean effective dose was 3 mSv. CONCLUSION: MBIR shows superior reduction in noise and improved image quality (both objective and subjective analysis) compared with ASIR and FBP CT KUB examinations. MAIN MESSAGES: • There are many reconstruction options in CT. • Novel model-based iterative reconstruction (MBIR) showed the least noise and optimal image quality. • For CT of the kidneys/ureters/bladder, MBIR should be utilised, if available. • Further studies to reduce the dose while maintaining image quality should be pursued. Springer Berlin Heidelberg 2013-08-10 /pmc/articles/PMC3781247/ /pubmed/23929357 http://dx.doi.org/10.1007/s13244-013-0273-5 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by-nc/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Vardhanabhuti, Varut
Ilyas, Sumaira
Gutteridge, Catherine
Freeman, Simon J.
Roobottom, Carl A.
Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title_full Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title_fullStr Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title_full_unstemmed Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title_short Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
title_sort comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal ct for renal calculi
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3781247/
https://www.ncbi.nlm.nih.gov/pubmed/23929357
http://dx.doi.org/10.1007/s13244-013-0273-5
work_keys_str_mv AT vardhanabhutivarut comparisonofimagequalitybetweenfilteredbackprojectionandtheadaptivestatisticalandnovelmodelbasediterativereconstructiontechniquesinabdominalctforrenalcalculi
AT ilyassumaira comparisonofimagequalitybetweenfilteredbackprojectionandtheadaptivestatisticalandnovelmodelbasediterativereconstructiontechniquesinabdominalctforrenalcalculi
AT gutteridgecatherine comparisonofimagequalitybetweenfilteredbackprojectionandtheadaptivestatisticalandnovelmodelbasediterativereconstructiontechniquesinabdominalctforrenalcalculi
AT freemansimonj comparisonofimagequalitybetweenfilteredbackprojectionandtheadaptivestatisticalandnovelmodelbasediterativereconstructiontechniquesinabdominalctforrenalcalculi
AT roobottomcarla comparisonofimagequalitybetweenfilteredbackprojectionandtheadaptivestatisticalandnovelmodelbasediterativereconstructiontechniquesinabdominalctforrenalcalculi