Cargando…

Development of a Chemiluminescence Immunoassay for Serum YB-1 and its Clinical Application as a Potential Diagnostic Marker for Hepatocellular Carcinoma

BACKGROUND: Y-box binding protein 1 (YB-1) overexpression has been shown in various tumor cells including hepatocellular carcinoma (HCC); moreover, this protein can be actively secreted. OBJECTIVES: The aim of this study was to establish a method to quantify serum YB-1 and evaluate its clinical appl...

Descripción completa

Detalles Bibliográficos
Autores principales: Pu, Li, Jing, Shi, Bianqin, Guo, Ping, Liu, Qindong, Liang, Chenggui, Liu, Feng, Cheng, Wenbin, Kuang, Qin, Wang, Jinyu, Dong, Qianfeng, Xia, Yu, Liu, Zhiguang, Tu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3782250/
https://www.ncbi.nlm.nih.gov/pubmed/24069038
http://dx.doi.org/10.5812/hepatmon.8918
Descripción
Sumario:BACKGROUND: Y-box binding protein 1 (YB-1) overexpression has been shown in various tumor cells including hepatocellular carcinoma (HCC); moreover, this protein can be actively secreted. OBJECTIVES: The aim of this study was to establish a method to quantify serum YB-1 and evaluate its clinical application in the clinical diagnosis of HCC. PATIENTS AND METHODS: Recombinant YB-1 and two populations of its antibodies were prepared. A monoclonal antibody was specific to the N-terminus of YB-1 amino acids 134-160; and another was a polyclonal antibody. A sandwich-type chemiluminescence immunoassay (CLIA) was developed and evaluated. Levels of YB-1 and alpha fetoprotein (AFP) in serum samples from 105 HCC patients, 25 hepatitis B virus patients, 25 cirrhosis patients, and 50 healthy donors were detected using the established method and an AFP electrochemiluminescence kit. RESULTS: The developed method was linear to 150 μg/L of YB-1 with a minimum detection limit of 0.01 μg/L. The average recoveries were between 93.9% and 109.0%. The mean intra- and inter-assay coefficients of variation (CVs) were 4.0-4.8% and 8.2-10.2%, respectively. The relationship between the concentration of diluted YB-1 and the dilution ratios gave a good linear correlation coefficient of 0.9986. The YB-1 concentration was increased in serum of HCC patients (33.0 ± 23.39 μg/L) compared to healthy individuals (13.2 ± 5.29 μg/L, P < 0.0001), patients with HBV (17.9 ± 7.49 μg/L, P = 0.0003), and patients with HBV cirrhosis (20.7 ± 8.75 μg/L, P < 0.05). Moreover, the combination of YB-1 and alpha-fetoprotein had a high sensitivity (89.5%) and reasonable specificity (62.0%) in identifying HCC. CONCLUSIONS: The established method has an acceptable performance in quantifying YB-1. In addition, serum YB-1 may aid in the diagnosis of HCC.