Cargando…

Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine

The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled....

Descripción completa

Detalles Bibliográficos
Autores principales: Hoang, Vu Dang, Huyen, Dao Thi, Phuc, Phan Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784228/
https://www.ncbi.nlm.nih.gov/pubmed/24109542
http://dx.doi.org/10.1155/2013/367914
_version_ 1782477529620152320
author Hoang, Vu Dang
Huyen, Dao Thi
Phuc, Phan Hong
author_facet Hoang, Vu Dang
Huyen, Dao Thi
Phuc, Phan Hong
author_sort Hoang, Vu Dang
collection PubMed
description The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled. Britton-Robinson buffer 0.04 M pH 4.0 was selected as a supporting electrolyte for quantitative purposes by differential pulse and square wave adsorptive cathodic stripping voltammetry. The experimental voltammetric conditions were optimized using Central Composite Face design. A reduction wave was seen in the range from −0.7 to −0.8 V. These voltammetric techniques were successfully validated as per ICH guidelines and applied for the determination of cefoperazone in its single and sulbactam containing powders for injection and statistically comparable to USP-HPLC. They were further extended to determine cefoperazone in spiked human urine with no matrix effect.
format Online
Article
Text
id pubmed-3784228
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37842282013-10-09 Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine Hoang, Vu Dang Huyen, Dao Thi Phuc, Phan Hong J Anal Methods Chem Research Article The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled. Britton-Robinson buffer 0.04 M pH 4.0 was selected as a supporting electrolyte for quantitative purposes by differential pulse and square wave adsorptive cathodic stripping voltammetry. The experimental voltammetric conditions were optimized using Central Composite Face design. A reduction wave was seen in the range from −0.7 to −0.8 V. These voltammetric techniques were successfully validated as per ICH guidelines and applied for the determination of cefoperazone in its single and sulbactam containing powders for injection and statistically comparable to USP-HPLC. They were further extended to determine cefoperazone in spiked human urine with no matrix effect. Hindawi Publishing Corporation 2013 2013-09-10 /pmc/articles/PMC3784228/ /pubmed/24109542 http://dx.doi.org/10.1155/2013/367914 Text en Copyright © 2013 Vu Dang Hoang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hoang, Vu Dang
Huyen, Dao Thi
Phuc, Phan Hong
Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title_full Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title_fullStr Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title_full_unstemmed Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title_short Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
title_sort adsorptive cathodic stripping voltammetric determination of cefoperazone in bulk powder, pharmaceutical dosage forms, and human urine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784228/
https://www.ncbi.nlm.nih.gov/pubmed/24109542
http://dx.doi.org/10.1155/2013/367914
work_keys_str_mv AT hoangvudang adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine
AT huyendaothi adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine
AT phucphanhong adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine