Cargando…
Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine
The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled....
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784228/ https://www.ncbi.nlm.nih.gov/pubmed/24109542 http://dx.doi.org/10.1155/2013/367914 |
_version_ | 1782477529620152320 |
---|---|
author | Hoang, Vu Dang Huyen, Dao Thi Phuc, Phan Hong |
author_facet | Hoang, Vu Dang Huyen, Dao Thi Phuc, Phan Hong |
author_sort | Hoang, Vu Dang |
collection | PubMed |
description | The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled. Britton-Robinson buffer 0.04 M pH 4.0 was selected as a supporting electrolyte for quantitative purposes by differential pulse and square wave adsorptive cathodic stripping voltammetry. The experimental voltammetric conditions were optimized using Central Composite Face design. A reduction wave was seen in the range from −0.7 to −0.8 V. These voltammetric techniques were successfully validated as per ICH guidelines and applied for the determination of cefoperazone in its single and sulbactam containing powders for injection and statistically comparable to USP-HPLC. They were further extended to determine cefoperazone in spiked human urine with no matrix effect. |
format | Online Article Text |
id | pubmed-3784228 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-37842282013-10-09 Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine Hoang, Vu Dang Huyen, Dao Thi Phuc, Phan Hong J Anal Methods Chem Research Article The electroreduction behaviour and determination of cefoperazone using a hanging mercury drop electrode were investigated. Cyclic voltammograms of cefoperazone recorded in universal Britton-Robinson buffers pH 3–6 exhibited a single irreversible cathodic peak. The process was adsorption-controlled. Britton-Robinson buffer 0.04 M pH 4.0 was selected as a supporting electrolyte for quantitative purposes by differential pulse and square wave adsorptive cathodic stripping voltammetry. The experimental voltammetric conditions were optimized using Central Composite Face design. A reduction wave was seen in the range from −0.7 to −0.8 V. These voltammetric techniques were successfully validated as per ICH guidelines and applied for the determination of cefoperazone in its single and sulbactam containing powders for injection and statistically comparable to USP-HPLC. They were further extended to determine cefoperazone in spiked human urine with no matrix effect. Hindawi Publishing Corporation 2013 2013-09-10 /pmc/articles/PMC3784228/ /pubmed/24109542 http://dx.doi.org/10.1155/2013/367914 Text en Copyright © 2013 Vu Dang Hoang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hoang, Vu Dang Huyen, Dao Thi Phuc, Phan Hong Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title | Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title_full | Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title_fullStr | Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title_full_unstemmed | Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title_short | Adsorptive Cathodic Stripping Voltammetric Determination of Cefoperazone in Bulk Powder, Pharmaceutical Dosage Forms, and Human Urine |
title_sort | adsorptive cathodic stripping voltammetric determination of cefoperazone in bulk powder, pharmaceutical dosage forms, and human urine |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3784228/ https://www.ncbi.nlm.nih.gov/pubmed/24109542 http://dx.doi.org/10.1155/2013/367914 |
work_keys_str_mv | AT hoangvudang adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine AT huyendaothi adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine AT phucphanhong adsorptivecathodicstrippingvoltammetricdeterminationofcefoperazoneinbulkpowderpharmaceuticaldosageformsandhumanurine |