Cargando…
Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced mag...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3788790/ https://www.ncbi.nlm.nih.gov/pubmed/24098370 http://dx.doi.org/10.1371/journal.pone.0075173 |
_version_ | 1782286360465375232 |
---|---|
author | Nguyen, V. Lai Kooi, M. Eline Backes, Walter H. van Hoof, Raf H. M. Saris, Anne E. C. M. Wishaupt, Mirthe C. J. Hellenthal, Femke A. M. V. I. van der Geest, Rob J. Kessels, Alfons G. H. Schurink, Geert Willem H. Leiner, Tim |
author_facet | Nguyen, V. Lai Kooi, M. Eline Backes, Walter H. van Hoof, Raf H. M. Saris, Anne E. C. M. Wishaupt, Mirthe C. J. Hellenthal, Femke A. M. V. I. van der Geest, Rob J. Kessels, Alfons G. H. Schurink, Geert Willem H. Leiner, Tim |
author_sort | Nguyen, V. Lai |
collection | PubMed |
description | PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS: Patients with AAA underwent DCE-MRI at 1.5 Tesla. The volume transfer constant (K(trans)), which reflects microvascular flow, permeability and surface area, was calculated by fitting the blood and aneurysm vessel wall gadolinium concentration curves. The relative fit errors, parameter uncertainties and parameter reproducibilities for the Patlak, Tofts and Extended Tofts model were compared to find the most suitable model. Scan-rescan reproducibility was assessed using the interclass correlation coefficient and coefficient of variation (CV). Further, the relationship between K(trans) and AAA size was investigated. RESULTS: DCE-MRI examinations from thirty-nine patients (mean age±SD: 72±6 years; M/F: 35/4) with an mean AAA maximal diameter of 49±6 mm could be included for pharmacokinetic analysis. Relative fit uncertainties for K(trans) based on the Patlak model (17%) were significantly lower compared to the Tofts (37%) and Extended Tofts model (42%) (p<0.001). K(trans) scan-rescan reproducibility for the Patlak model (ICC = 0.61 and CV = 22%) was comparable with the Tofts (ICC = 0.61, CV = 23%) and Extended Tofts model (ICC = 0.76, CV = 22%). K(trans) was positively correlated with maximal AAA diameter (Spearman’s ρ = 0.38, p = 0.02) using the Patlak model. CONCLUSION: Using the presented imaging protocol, the Patlak model is most suited to describe DCE-MRI data of the AAA vessel wall with good K(trans) scan-rescan reproducibility. |
format | Online Article Text |
id | pubmed-3788790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-37887902013-10-04 Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison Nguyen, V. Lai Kooi, M. Eline Backes, Walter H. van Hoof, Raf H. M. Saris, Anne E. C. M. Wishaupt, Mirthe C. J. Hellenthal, Femke A. M. V. I. van der Geest, Rob J. Kessels, Alfons G. H. Schurink, Geert Willem H. Leiner, Tim PLoS One Research Article PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS: Patients with AAA underwent DCE-MRI at 1.5 Tesla. The volume transfer constant (K(trans)), which reflects microvascular flow, permeability and surface area, was calculated by fitting the blood and aneurysm vessel wall gadolinium concentration curves. The relative fit errors, parameter uncertainties and parameter reproducibilities for the Patlak, Tofts and Extended Tofts model were compared to find the most suitable model. Scan-rescan reproducibility was assessed using the interclass correlation coefficient and coefficient of variation (CV). Further, the relationship between K(trans) and AAA size was investigated. RESULTS: DCE-MRI examinations from thirty-nine patients (mean age±SD: 72±6 years; M/F: 35/4) with an mean AAA maximal diameter of 49±6 mm could be included for pharmacokinetic analysis. Relative fit uncertainties for K(trans) based on the Patlak model (17%) were significantly lower compared to the Tofts (37%) and Extended Tofts model (42%) (p<0.001). K(trans) scan-rescan reproducibility for the Patlak model (ICC = 0.61 and CV = 22%) was comparable with the Tofts (ICC = 0.61, CV = 23%) and Extended Tofts model (ICC = 0.76, CV = 22%). K(trans) was positively correlated with maximal AAA diameter (Spearman’s ρ = 0.38, p = 0.02) using the Patlak model. CONCLUSION: Using the presented imaging protocol, the Patlak model is most suited to describe DCE-MRI data of the AAA vessel wall with good K(trans) scan-rescan reproducibility. Public Library of Science 2013-10-02 /pmc/articles/PMC3788790/ /pubmed/24098370 http://dx.doi.org/10.1371/journal.pone.0075173 Text en © 2013 Nguyen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Nguyen, V. Lai Kooi, M. Eline Backes, Walter H. van Hoof, Raf H. M. Saris, Anne E. C. M. Wishaupt, Mirthe C. J. Hellenthal, Femke A. M. V. I. van der Geest, Rob J. Kessels, Alfons G. H. Schurink, Geert Willem H. Leiner, Tim Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title | Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title_full | Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title_fullStr | Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title_full_unstemmed | Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title_short | Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison |
title_sort | suitability of pharmacokinetic models for dynamic contrast-enhanced mri of abdominal aortic aneurysm vessel wall: a comparison |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3788790/ https://www.ncbi.nlm.nih.gov/pubmed/24098370 http://dx.doi.org/10.1371/journal.pone.0075173 |
work_keys_str_mv | AT nguyenvlai suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT kooimeline suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT backeswalterh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT vanhoofrafhm suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT sarisanneecm suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT wishauptmirthecj suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT hellenthalfemkeamvi suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT vandergeestrobj suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT kesselsalfonsgh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT schurinkgeertwillemh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison AT leinertim suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison |