Cargando…

Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison

PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced mag...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, V. Lai, Kooi, M. Eline, Backes, Walter H., van Hoof, Raf H. M., Saris, Anne E. C. M., Wishaupt, Mirthe C. J., Hellenthal, Femke A. M. V. I., van der Geest, Rob J., Kessels, Alfons G. H., Schurink, Geert Willem H., Leiner, Tim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3788790/
https://www.ncbi.nlm.nih.gov/pubmed/24098370
http://dx.doi.org/10.1371/journal.pone.0075173
_version_ 1782286360465375232
author Nguyen, V. Lai
Kooi, M. Eline
Backes, Walter H.
van Hoof, Raf H. M.
Saris, Anne E. C. M.
Wishaupt, Mirthe C. J.
Hellenthal, Femke A. M. V. I.
van der Geest, Rob J.
Kessels, Alfons G. H.
Schurink, Geert Willem H.
Leiner, Tim
author_facet Nguyen, V. Lai
Kooi, M. Eline
Backes, Walter H.
van Hoof, Raf H. M.
Saris, Anne E. C. M.
Wishaupt, Mirthe C. J.
Hellenthal, Femke A. M. V. I.
van der Geest, Rob J.
Kessels, Alfons G. H.
Schurink, Geert Willem H.
Leiner, Tim
author_sort Nguyen, V. Lai
collection PubMed
description PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS: Patients with AAA underwent DCE-MRI at 1.5 Tesla. The volume transfer constant (K(trans)), which reflects microvascular flow, permeability and surface area, was calculated by fitting the blood and aneurysm vessel wall gadolinium concentration curves. The relative fit errors, parameter uncertainties and parameter reproducibilities for the Patlak, Tofts and Extended Tofts model were compared to find the most suitable model. Scan-rescan reproducibility was assessed using the interclass correlation coefficient and coefficient of variation (CV). Further, the relationship between K(trans) and AAA size was investigated. RESULTS: DCE-MRI examinations from thirty-nine patients (mean age±SD: 72±6 years; M/F: 35/4) with an mean AAA maximal diameter of 49±6 mm could be included for pharmacokinetic analysis. Relative fit uncertainties for K(trans) based on the Patlak model (17%) were significantly lower compared to the Tofts (37%) and Extended Tofts model (42%) (p<0.001). K(trans) scan-rescan reproducibility for the Patlak model (ICC = 0.61 and CV = 22%) was comparable with the Tofts (ICC = 0.61, CV = 23%) and Extended Tofts model (ICC = 0.76, CV = 22%). K(trans) was positively correlated with maximal AAA diameter (Spearman’s ρ = 0.38, p = 0.02) using the Patlak model. CONCLUSION: Using the presented imaging protocol, the Patlak model is most suited to describe DCE-MRI data of the AAA vessel wall with good K(trans) scan-rescan reproducibility.
format Online
Article
Text
id pubmed-3788790
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37887902013-10-04 Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison Nguyen, V. Lai Kooi, M. Eline Backes, Walter H. van Hoof, Raf H. M. Saris, Anne E. C. M. Wishaupt, Mirthe C. J. Hellenthal, Femke A. M. V. I. van der Geest, Rob J. Kessels, Alfons G. H. Schurink, Geert Willem H. Leiner, Tim PLoS One Research Article PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA) vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS: Patients with AAA underwent DCE-MRI at 1.5 Tesla. The volume transfer constant (K(trans)), which reflects microvascular flow, permeability and surface area, was calculated by fitting the blood and aneurysm vessel wall gadolinium concentration curves. The relative fit errors, parameter uncertainties and parameter reproducibilities for the Patlak, Tofts and Extended Tofts model were compared to find the most suitable model. Scan-rescan reproducibility was assessed using the interclass correlation coefficient and coefficient of variation (CV). Further, the relationship between K(trans) and AAA size was investigated. RESULTS: DCE-MRI examinations from thirty-nine patients (mean age±SD: 72±6 years; M/F: 35/4) with an mean AAA maximal diameter of 49±6 mm could be included for pharmacokinetic analysis. Relative fit uncertainties for K(trans) based on the Patlak model (17%) were significantly lower compared to the Tofts (37%) and Extended Tofts model (42%) (p<0.001). K(trans) scan-rescan reproducibility for the Patlak model (ICC = 0.61 and CV = 22%) was comparable with the Tofts (ICC = 0.61, CV = 23%) and Extended Tofts model (ICC = 0.76, CV = 22%). K(trans) was positively correlated with maximal AAA diameter (Spearman’s ρ = 0.38, p = 0.02) using the Patlak model. CONCLUSION: Using the presented imaging protocol, the Patlak model is most suited to describe DCE-MRI data of the AAA vessel wall with good K(trans) scan-rescan reproducibility. Public Library of Science 2013-10-02 /pmc/articles/PMC3788790/ /pubmed/24098370 http://dx.doi.org/10.1371/journal.pone.0075173 Text en © 2013 Nguyen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Nguyen, V. Lai
Kooi, M. Eline
Backes, Walter H.
van Hoof, Raf H. M.
Saris, Anne E. C. M.
Wishaupt, Mirthe C. J.
Hellenthal, Femke A. M. V. I.
van der Geest, Rob J.
Kessels, Alfons G. H.
Schurink, Geert Willem H.
Leiner, Tim
Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title_full Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title_fullStr Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title_full_unstemmed Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title_short Suitability of Pharmacokinetic Models for Dynamic Contrast-Enhanced MRI of Abdominal Aortic Aneurysm Vessel Wall: A Comparison
title_sort suitability of pharmacokinetic models for dynamic contrast-enhanced mri of abdominal aortic aneurysm vessel wall: a comparison
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3788790/
https://www.ncbi.nlm.nih.gov/pubmed/24098370
http://dx.doi.org/10.1371/journal.pone.0075173
work_keys_str_mv AT nguyenvlai suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT kooimeline suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT backeswalterh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT vanhoofrafhm suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT sarisanneecm suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT wishauptmirthecj suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT hellenthalfemkeamvi suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT vandergeestrobj suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT kesselsalfonsgh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT schurinkgeertwillemh suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison
AT leinertim suitabilityofpharmacokineticmodelsfordynamiccontrastenhancedmriofabdominalaorticaneurysmvesselwallacomparison