Cargando…

Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System

The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18–23 mm in length and with a 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Hasheminia, Seyed Mohsen, Farhadi, Nastaran, Shokraneh, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3789411/
https://www.ncbi.nlm.nih.gov/pubmed/24159390
http://dx.doi.org/10.1155/2013/704027
_version_ 1782286443066949632
author Hasheminia, Seyed Mohsen
Farhadi, Nastaran
Shokraneh, Ali
author_facet Hasheminia, Seyed Mohsen
Farhadi, Nastaran
Shokraneh, Ali
author_sort Hasheminia, Seyed Mohsen
collection PubMed
description The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18–23 mm in length and with a 25–40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P < 0.001). There were significant relationships between the angle of curvature, transportation and curve straightening in pairs (P < 0.001). Apical patency is recommended during root canal preparation with the ProTaper rotary system.
format Online
Article
Text
id pubmed-3789411
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-37894112013-10-24 Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System Hasheminia, Seyed Mohsen Farhadi, Nastaran Shokraneh, Ali ISRN Dent Research Article The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18–23 mm in length and with a 25–40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P < 0.001). There were significant relationships between the angle of curvature, transportation and curve straightening in pairs (P < 0.001). Apical patency is recommended during root canal preparation with the ProTaper rotary system. Hindawi Publishing Corporation 2013-09-12 /pmc/articles/PMC3789411/ /pubmed/24159390 http://dx.doi.org/10.1155/2013/704027 Text en Copyright © 2013 Seyed Mohsen Hasheminia et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hasheminia, Seyed Mohsen
Farhadi, Nastaran
Shokraneh, Ali
Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title_full Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title_fullStr Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title_full_unstemmed Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title_short Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System
title_sort effect of patency file on transportation and curve straightening in canal preparation with protaper system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3789411/
https://www.ncbi.nlm.nih.gov/pubmed/24159390
http://dx.doi.org/10.1155/2013/704027
work_keys_str_mv AT hasheminiaseyedmohsen effectofpatencyfileontransportationandcurvestraighteningincanalpreparationwithprotapersystem
AT farhadinastaran effectofpatencyfileontransportationandcurvestraighteningincanalpreparationwithprotapersystem
AT shokranehali effectofpatencyfileontransportationandcurvestraighteningincanalpreparationwithprotapersystem